Rackmount Kit (Option 300)
Rackmount Kit (Option 300)
Item Part number Description Quantity Item Part number Description Quantity
A E5810-00031 Rack ear - side 1 E 0515-1114 Panhead screw, M4X10 8
B E5810-00022 Rack ear - half rack 1 F 0570-1577 Machine screw 4
C E5810-00035 Power adapter holder 1 G 0590-0804 Machine nut 4
D 0950-5481 Power adapter 1
1 Remove both rubber bumpers from the E5810B.
2 Using a Torx screwdriver, attach the rack ear - half rack (B) to the E5810B with three
panhead screws, M4X10 (E).
3 Plug the E5810B power adapter (D) into the DC power port of the E5810B. Place the
power adapter into the power adapter holder (C).
4 Using a Torx screwdriver, attach the rack ear - side (A) to the E5810B and the power
adapter holder (C) with five panhead screws, M4X10 (E).
2 E5810B Rackmount Installation Guide (Option 300)
Rackmount Kit (Option 300)
5 Using a Torx screwdriver, attach the rack ears to the rack with four machine screws (F)
and four machine nuts (G).
E5810B Rackmount Installation Guide (Option 300) 3
www.agilent.com
Contact us
To obtain service, warranty, or technical
assistance, contact us at the following
phone or fax numbers:
United States:
(tel) 800 829 4444 (fax) 800 829 4433
Canada:
(tel) 877 894 4414 (fax) 800 746 4866
China:
(tel) 800 810 0189 (fax) 800 820 2816
Europe:
(tel) 31 20 547 2111
Japan:
(tel) 0120 (421) 345 (fax) 0120 (421) 678
Korea:
(tel) (080) 769 0800 (fax) (080) 769 0900
Latin America:
(tel) (305) 269 7500
Taiwan:
(tel) 0800 047 866 (fax) 0800 286 331
Other Asia Pacific Countries:
(tel) (65) 6375 8100 (fax) (65) 6755 0042
Or visit Agilent World Wide Web at:
www.agilent.com/find/assist
Product specifications and descriptions in
this document are subject to change
without notice. Always refer to the Agilent
Web site for the latest revision.