Text preview for : lm12cl.pdf part of National Semiconductor LM12 LM12 80W operational amplifier



Back to : lm12cl.pdf | Home

LM12 80W Operational Amplifier

March 1995

LM12 80W Operational Amplifier
General Description
The LM12 is a power op amp capable of driving g 25V at g 10A while operating from g 30V supplies The monolithic IC can deliver 80W of sine wave power into a 4X load with 0 01% distortion Power bandwidth is 60 kHz Further a peak dissipation capability of 800W allows it to handle reactive loads such as transducers actuators or small motors without derating Important features include Y input protection Y controlled turn on Y thermal limiting Y overvoltage shutdown Y output-current limiting Y dynamic safe-area protection The IC delivers g 10A output current at any output voltage yet is completely protected against overloads including shorts to the supplies The dynamic safe-area protection is provided by instantaneous peak-temperature limiting within the power transistor array The turn-on characteristics are controlled by keeping the output open-circuited until the total supply voltage reaches 14V The output is also opened as the case temperature exceeds 150 C or as the supply voltage approaches the BVCEO of the output transistors The IC withstands overvoltages to 80V This monolithic op amp is compensated for unity-gain feedback with a small-signal bandwidth of 700 kHz Slew rate is 9V ms even as a follower Distortion and capacitive-load stability rival that of the best designs using complementary output transistors Further the IC withstands large differential input voltages and is well behaved should the commonmode range be exceeded The LM12 establishes that monolithic ICs can deliver considerable output power without resorting to complex switching schemes Devices can be paralleled or bridged for even greater output capability Applications include operational power supplies high-voltage regulators high-quality audio amplifiers tape-head positioners x-y plotters or other servo-control systems b The LM12 is supplied in a four-lead TO-3 package with V on the case A gold-eutectic die-attach to a molybdenum interface is used to avoid thermal fatigue problems The LM12 is specified for either military or commercial temperature range

Connection Diagram
4-pin glass epoxy TO-3 socket is available from AUGAT INC Part number 8112-AG7

Typical Application

TL H 8704 ­ 2 TL H 8704 ­ 1

Low distortion (0 01%) audio amplifier

Bottom View Order Number LM12CLK See NS Package Number K04A

C1995 National Semiconductor Corporation

TL H 8704

RRD-B30M115 Printed in U S A

Absolute Maximum Ratings
If Military Aerospace specified devices are required please contact the National Semiconductor Sales Office Distributors for availability and specifications Total Supply Voltage (Note 1) Input Voltage Output Current 80V (Note 2) Internally Limited Junction Temperature Storage Temperature Range Lead Temperature (Soldering 10 seconds) (Note 3)
b 65 C to 150 C

300 C

Operating Ratings
Total Supply Voltage Case Temperature (Note 4) 15V to 60V 0 C to 70 C

Electrical Characteristics (Note 4)
Parameter Input Offset Voltage Input Bias Current Input Offset Current Common Mode Rejection Power Supply Rejection Conditions
g 10V s VS s g 0 5 VMAX VCM e 0

Typ 25 C 2 0 15 0 03 86 90 110

LM12CL Limits 15 20 07 10 02 03 70 65 70 65 75 70

Units mV (max) mA (max) mA (max) dB (min) dB (min) dB (min)

V V V V

b b b

a 4V s VCM s V

a

b 2V

a 4V s VCM s V a b 2V a 4V s VCM s V a b 2V

e 0 5 VMAX b 6V t V b t b 0 5 VMAX b V e b0 5 VMAX

a

6V s V Output Saturation Threshold

a s

0 5 VMAX

tON e 1 ms DVIN e 5 (10) mV IOUT e 1A 8A 10A tON e 2 ms VSAT e 2V IOUT e 0 VSAT e 8V RL e 4X PDISS e 50W tON e 65 ms tON e 10 ms VDISS e 10V tON e 100 ms VDISS e 58V

18 4 5 100 50 30 13 15 15 100 80 23 27 16 60

22 25 5 7

V (max) V (max) V (max) V mV (min) V mV (min) mV W (max) A (max) A (min) A (max) W (min) W (min) C W (max) C W (max) C W (max) mA (max)

Large Signal Voltage Gain Thermal Gradient Feedback Output-Current Limit

30 20 15 10 100 16 09 06 17 80 55 52 35 29 45 21 120 140

Power Dissipation Rating DC Thermal Resistance AC Thermal Resistance Supply Current

tON e 100 ms VDISS e 20V VDISS e 58V (Note 5) (Note 5) VOUT e 0 IOUT e 0 VDISS e 20V VDISS e 58V

Note 1 Absolute maximum ratings indicate limits beyond which damage to the device may occur The maximum voltage for which the LM12 is guaranteed to operate is given in the operating ratings and in Note 4 With inductive loads or output shorts other restrictions described in applications section apply Note 2 Neither input should exceed the supply voltage by more than 50 volts nor should the voltage between one input and any other terminal exceed 60 volts Note 3 Operating junction temperature is internally limited near 225 C within the power transistor and 160 C for the control circuitry Note 4 The supply voltage is g 30V (VMAX e 60V) unless otherwise specified The voltage across the conducting output transistor (supply to output) is VDISS and internal power dissipation is PDISS Temperature range is 0 C s TC s 70 C where TC is the case temperature Standard typeface indicates limits at 25 C while boldface type refers to limits or special conditions over full temperature range With no heat sink the package will heat at a rate of 35 C sec per 100W of internal dissipation Note 5 This thermal resistance is based upon a peak temperature of 200 C in the center of the power transistor and a case temperature of 25 C measured at the center of the package bottom The maximum junction temperature of the control circuitry can be estimated based upon a dc thermal resistance of 0 9 C W or an ac thermal resistance of 0 6 C W for any operating voltage

Although the output and supply leads are resistant to electrostatic discharges from handling the input leads are not The part should be treated accordingly

2

Output-Transistor Ratings (guaranteed)
Safe Area DC Thermal Resistance Pulse Thermal Resistance

TL H 8704 ­ 3

Typical Performance Characteristics
Pulse Power Limit Pulse Power Limit Peak Output Current

Output Saturation Voltage

Large Signal Response

Follower Pulse Response

TL H 8704 ­ 4

3

Typical Performance Characteristics
Large Signal Gain

(Continued) Total Harmonic Distortion

Thermal Response

Frequency Response

Output Impedance

Power Supply Rejection

Input Bias Current

Input Noise Voltage

Common Mode Rejection

Supply Current

Supply Current

Cross-Supply Current

TL H 8704 ­ 5

4

Application Information
GENERAL Twenty five years ago the operational amplifier was a specialized design tool used primarily for analog computation However the availability of low cost IC op amps in the late 1960's prompted their use in rather mundane applications replacing a few discrete components Once a few basic principles are mastered op amps can be used to give exceptionally good results in a wide range of applications while minimizing both cost and design effort The availability of a monolithic power op amp now promises to extend these advantages to high-power designs Some conventional applications are given here to illustrate op amp design principles as they relate to power circuitry The inevitable fall in prices as the economies of volume production are realized will prompt their use in applications that might now seem trivial Replacing single power transistors with an op amp will become economical because of improved performance simplification of attendant circuitry vastly improved fault protection greater reliability and the reduction of design time Power op amps introduce new factors into the design equation With current transients above 10A both the inductance and resistance of wire interconnects become important in a number of ways Further power ratings are a crucial factor in determining performance But the power capability of the IC cannot be realized unless it is properly mounted to an adequate heat sink Thus thermal design is of major importance with power op amps This application summary starts off by identifying the origin of strange problems observed while using the LM12 in a wide variety of designs with all sorts of fault conditions A few simple precautions will eliminate these problems One would do well to read the section on supply bypassing lead inductance output clamp diodes ground loops and reactive loading before doing any experimentation Should there be problems with erratic operation blowouts excessive distortion or oscillation another look at these sections is in order The management and protection circuitry can also affect operation Should the total supply voltage exceed ratings or drop below 15­20V the op amp shuts off completely Case temperatures above 150 C also cause shut down until the temperature drops to 145 C This may take several seconds depending on the thermal system Activation of the dynamic safe-area protection causes both the main feedback loop to lose control and a reduction in output power with possible oscillations In ac applications the dynamic protection will cause waveform distortion Since the LM12 is well protected against thermal overloads the suggestions for determining power dissipation and heat sink requirements are presented last SUPPLY BYPASSING All op amps should have their supply leads bypassed with low-inductance capacitors having short leads and located close to the package terminals to avoid spurious oscillation problems Power op amps require larger bypass capacitors The LM12 is stable with good-quality electrolytic bypass capacitors greater than 20 mF Other considerations may require larger capacitors The current in the supply leads is a rectified component of the load current If adequate bypassing is not provided this distorted signal can be fed back into internal circuitry Low distortion at high frequencies requires that the supplies be bypassed with 470 mF or more at the package terminals LEAD INDUCTANCE With ordinary op amps lead-inductance problems are usually restricted to supply bypassing Power op amps are also sensitive to inductance in the output lead particularly with heavy capacitive loading Feedback to the input should be taken directly from the output terminal minimizing common inductance with the load Sensing to a remote load must be accompanied by a high-frequency feedback path directly from the output terminal Lead inductance can also cause voltage surges on the supplies With long leads to the power source energy stored in the lead inductance when the output is shorted can be dumped back into the supply bypass capacitors when the short is removed The magnitude of this transient is reduced by increasing the size of the bypass capacitor near the IC With 20 mF local bypass these voltage surges are important only if the lead length exceeds a couple feet (l 1 mH lead inductance) Twisting together the supply and ground leads minimizes the effect GROUND LOOPS With fast high-current circuitry all sorts of problems can arise from improper grounding In general difficulties can be avoided by returning all grounds separately to a common point Sometimes this is impractical When compromising special attention should be paid to the ground returns for the supply bypasses load and input signal Ground planes also help to provide proper grounding Many problems unrelated to system performance can be traced to the grounding of line-operated test equipment used for system checkout Hidden paths are particularly difficult to sort out when several pieces of test equipment are used but can be minimized by using current probes or the new isolated oscilloscope pre-amplifiers Eliminating any direct ground connection between the signal generator and the oscilloscope synchronization input solves one common problem OUTPUT CLAMP DIODES When a push-pull amplifier goes into power limit while driving an inductive load the stored energy in the load inductance can drive the output outside the supplies Although the LM12 has internal clamp diodes that can handle several amperes for a few milliseconds extreme conditions can cause destruction of the IC The internal clamp diodes are imperfect in that about half the clamp current flows into the supply to which the output is clamped while the other half flows across the supplies Therefore the use of external diodes to clamp the output to the power supplies is strongly recommended This is particularly important with higher supply voltages Experience has demonstrated that hard-wire shorting the output to the supplies can induce random failures if these external clamp diodes are not used and the supply voltages are above g 20V Therefore it is prudent to use output-

5

Application Information (Continued)
clamp diodes even when the load is not particularly inductive This also applies to experimental setups in that blowouts have been observed when diodes were not used In packaged equipment it may be possible to eliminate these diodes providing that fault conditions can be controlled and expected nature of the load but are not critical A 4 mH inductor is obtained with 14 turns of number 18 wire close spaced around a one-inch-diameter form

TL H 8704 ­ 8

TL H 8704­6

Heat sinking of the clamp diodes is usually unimportant in that they only clamp current transients Forward drop with 15A fault transients is of greater concern Usually these transients die out rapidly The clamp to the negative supply can have somewhat reduced effectiveness under worst case conditions should the forward drop exceed 1 0V Mounting this diode to the power op amp heat sink improves the situation Although the need has only been demonstrated with some motor loads including a third diode (D3 above) will eliminate any concern about the clamp diodes This diode however must be capable of dissipating continuous power as determined by the negative supply current of the op amp REACTIVE LOADING The LM12 is normally stable with resistive inductive or smaller capacitive loads Larger capacitive loads interact with the open-loop output resistance (about 1X) to reduce the phase margin of the feedback loop ultimately causing oscillation The critical capacitance depends upon the feedback applied around the amplifier a unity-gain follower can handle about 0 01 mF while more than 1 mF does not cause problems if the loop gain is ten With loop gains greater than unity a speedup capacitor across the feedback resistor will aid stability In all cases the op amp will behave predictably only if the supplies are properly bypassed ground loops are controlled and high-frequency feedback is derived directly from the output terminal as recommended earlier So-called capacitive loads are not always capacitive A high-Q capacitor in combination with long leads can present a series-resonant load to the op amp In practice this is not usually a problem but the situation should be kept in mind

The LM12 can be made stable for all loads with a large capacitor on the output as shown above This compensation gives the lowest possible closed-loop output impedance at high frequencies and the best load-transient response It is appropriate for such applications as voltage regulators A feedback capacitor C1 is connected directly to the output pin of the IC The output capacitor C2 is connected at the output terminal with short leads Single-point grounding to avoid dc and ac ground loops is advised The impedance Z1 is the wire connecting the op amp output to the load capacitor About 3-inches of number-18 wire (70 nH) gives good stability and 18-inches (400 nH) begins to degrade load-transient response The minimum load capacitance is 47 mF if a solid-tantalum capacitor with an equivalent series resistance (ESR) of 0 1X is used Electrolytic capacitors work as well although capacitance may have to be increased to 200 mF to bring ESR below 0 1X Loop stability is not the only concern when op amps are operated with reactive loads With time-varying signals power dissipation can also increase markedly This is particularly true with the combination of capacitive loads and high-frequency excitation INPUT COMPENSATION The LM12 is prone to low-amplitude oscillation bursts coming out of saturation if the high-frequency loop gain is near unity The voltage follower connection is most susceptible This glitching can be eliminated at the expense of small-signal bandwidth using input compensation Input compensation can also be used in combination with LR load isolation to improve capacitive load stability

TL H 8704­7

TL H 8704 ­ 9

Large capacitive loads (including series-resonant) can be accommodated by isolating the feedback amplifier from the load as shown above The inductor gives low output impedance at lower frequencies while providing an isolating impedance at high frequencies The resistor kills the Q of series resonant circuits formed by capacitive loads A low inductance carbon-composition resistor is recommended Optimum values of L and R depend upon the feedback gain 6

An example of a voltage follower with input compensation is shown here The R2C2 combination across the input works with R1 to reduce feedback at high frequencies without greatly affecting response below 100 kHz A lead capacitor C1 improves phase margin at the unity-gain crossover frequency Proper operation requires that the output impedance of the circuitry driving the follower be well under 1 kX at frequencies up to a few hundred kilohertz

Application Information (Continued)
equalization resistors More output buffers with individual equalization resistors may be added to meet even higher drive requirements

TL H 8704 ­ 10

Extending input compensation to the integrator connection is shown here Both the follower and this integrator will handle 1 mF capacitive loading without LR output isolation CURRENT DRIVE
R2 VIN R1 R6

TL H 8704 ­ 13

IOUT e

TL H 8704 ­ 11

This circuit provides an output current proportional to the input voltage Current drive is sometimes preferred for servo motors because it aids in stabilizing the servo loop by reducing phase lag caused by motor inductance In applications requiring high output resistance such as operational power supplies running in the current mode matching of the feedback resistors to 0 01% is required Alternately an adjustable resistor can be used for trimming PARALLEL OPERATION

This connection allows increased output capability without requiring a separate control amplifier The output buffer A2 provides load current through R5 equal to that supplied by the main amplifier A1 through R4 Again more output buffers can be added Current sharing among paralleled amplifiers can be affected by gain error as the power-bandwidth limit is approached In the first circuit the operating current increase will depend upon the matching of high-frequency characteristics In the second circuit however the entire input error of A2 appears across R4 and R5 The supply current increase can cause power limiting to be activated as the slew limit is approached This will not damage the LM12 It can be avoided in both cases by connecting A1 as an inverting amplifier and restricting bandwidth with C1 SINGLE-SUPPLY OPERATION

TL H 8704 ­ 14

TL H 8704 ­ 12

Output drive beyond the capability of one power amplifier can be provided as shown here The power op amps are wired as followers and connected in parallel with the outputs coupled through equalization resistors A standard high-voltage op amp is used to provide voltage gain Overall feedback compensates for the voltage dropped across the equalization resistors With parallel operation there may be an increase in unloaded supply current related to the offset voltage across the

Although op amps are usually operated from dual supplies single-supply operation is practical This bridge amplifier supplies bi-directional current drive to a servo motor while operating from a single positive supply The output is easily converted to voltage drive by shorting R6 and connecting R7 to the output of A2 rather than A1 Either input may be grounded with bi-directional drive provided to the other It is also possible to connect one input to a positive reference with the input signal varying about this voltage If the reference voltage is above 5V R2 and R3 are not required

7

Application Information (Continued)
HIGH VOLTAGE AMPLIFIERS

TL H 8704­15

The voltage swing delivered to the load can be doubled by using the bridge connection shown here Output clamping to the supplies can be provided by using a bridge-rectifier assembly

TL H 8704 ­ 16

One limitation of the standard bridge connection is that the load cannot be returned to ground This can be circumvented by operating the bridge with floating supplies as shown above For single-ended drive either input can be grounded

TL H 8704 ­ 17

This circuit shows how two amplifiers can be cascaded to double output swing The advantage over the bridge is that the output can be increased with any number of stages although separate supplies are required for each

TL H 8704 ­ 18

Discrete transistors can be used to increase output drive to g 70V at g 10A as shown above With proper thermal design the IC will provide safe-area protection for the external transistors Voltage gain is about thirty

8

Application Information (Continued)
OPERATIONAL POWER SUPPLY

Note Supply voltages for the LM318s are g 15V

TL H 8704 ­ 19

External current limit can be provided for a power op amp as shown above The positive and negative current limits can be set precisely and independently Fast response is assured by D1 and D2 Adjustment range can be set down to zero with potentiometers R3 and R7 Alternately the limit can be programmed from a voltage supplied to R2 and R6 This is the set up required for an operational power supply or voltage-programmable power source SERVO AMPLIFIERS When making servo systems with a power op amp there is a temptation to use it for frequency shaping to stabilize the servo loop Sometimes this works other times there are better ways and occasionally it just doesn't fly Usually it's a matter of how quickly and to what accuracy the servo must stabilize

TL H 8704 ­ 21

TL H 8704 ­ 20

This motor tachometer servo gives an output speed proportional to input voltage A low-level op amp is used for frequency shaping while the power op amp provides current drive to the motor Current drive eliminates loop phase shift due to motor inductance and makes high-performance servos easier to stabilize

This position servo uses an op amp to develop the rate signal electrically instead of using a tachometer In high-performance servos rate signals must be developed with large error signals well beyond saturation of the motor drive Using a separate op amp with a feedback clamp allows the rate signal to be developed properly with position errors more than an order of magnitude beyond the loop-saturation level as long as the photodiode sensors are positioned with this in mind

9

Application Information (Continued)
VOLTAGE REGULATORS REMOTE SENSING

TL H 8704­22

TL H 8704 ­ 24

An op amp can be used as a positive or negative regulator Unlike most regulators it can sink current to absorb energy dumped back into the output This positive regulator has a 0 ­ 50V output range

Remote sensing as shown above allows the op amp to correct for dc drops in cables connecting the load Even so cable drop will affect transient response Degradation can be minimized by using twisted heavy-gauge wires on the output line Normally common and one input are connected together at the sending end AUDIO AMPLIFIERS

TL H 8704 ­ 25

TL H 8704­23

Dual supplies are not required to use an op amp as a voltage regulator if zero output is not required This 4V to 50V regulator operates from a single supply Should the op amp not be able to absorb enough energy to control an overvoltage condition a SCR will crowbar the output

A power amplifier suitable for use in high-quality audio equipment is shown above Harmonic distortion is about 0 01-percent Intermodulation distortion (60 Hz 7 kHz 4 1) measured 0 015-percent Transient response and saturation recovery are clean and the 9 V ms slew rate of the LM12 virtually eliminates transient intermodulation distortion Using separate amplifiers to drive low- and high-frequency speakers gets rid of high-level crossover networks and attenuators Further it prevents clipping on the low-frequency channel from distorting the high frequencies

10

Application Information (Continued)
DETERMINING MAXIMUM DISSIPATION It is a simple matter to establish power requirements for an op amp driving a resistive load at frequencies well below 10 Hz Maximum dissipation occurs when the output is at one-half the supply voltage with high-line conditions The individual output transistors must be rated to handle this power continuously at the maximum expected case temperature The power rating is limited by the maximum junction temperature as determined by TJ e TC a PDISS iJC where TC is the case temperature as measured at the center of the package bottom PDISS is the maximum power dissipation and iJC is the thermal resistance at the operating voltage of the output transistor Recommended maximum junction temperatures are 200 C within the power transistor and 150 C for the control circuitry If there is ripple on the supply bus it is valid to use the average value in worst-case calculations as long as the peak rating of the power transistor is not exceeded at the ripple peak With 120 Hz ripple this is 1 5 times the continuous power rating Dissipation requirements are not so easily established with time varying output signals especially with reactive loads Both peak and continuous dissipation ratings must be taken into account and these depend on the signal waveform as well as load characteristics With a sine wave output analysis is fairly straightforward With supply voltages of g VS the maximum average power dissipation of both output transistors is PMAX e and VS2 4 b cosi i t 40 PMAX e 2ZL q where ZL is the magnitude of the load impedance and i its phase angle Maximum average dissipation occurs below maximum output swing for i k 40 2VS2 audio applications The peak dissipation of each transistor is about four times average In ac applications power capability is often limited by the peak ratings of the power transistor The pulse thermal resistance of the LM12 is specified for constant power pulse duration Establishing an exact equivalency between constant-power pulses and those encountered in practice is not easy However for sine waves reasonable estimates can be made at any frequency by assuming a constant power pulse amplitude given by VS2 PPK j 1-cos (w ­ i) 2ZL where w e 60 and i is the absolute value of the phase angle of ZL Equivalent pulse width is tON j 0 4u for i e 0 and tON j 0 2u for i t 20 where u is the period of the output waveform

(

q2 ZLcosi

i k 40

(

DISSIPATION DRIVING MOTORS A motor with a locked rotor looks like an inductance in series with a resistance for purposes of determining driver dissipation With slow-response servos the maximum signal amplitude at frequencies where motor inductance is significant can be so small that motor inductance does not have to be taken into account If this is the case the motor can be treated as a simple resistive load as long as the rotor speed is low enough that the back emf is small by comparison to the supply voltage of the driver transistor A permanent-magnet motor can build up a back emf that is equal to the output swing of the op amp driving it Reversing this motor from full speed requires the output drive transistor to operate initially along a loadline based upon the motor resistance and total supply voltage Worst case this loadline will have to be within the continuous dissipation rating of the drive transistor but system dynamics may permit taking advantage of the higher pulse ratings Motor inductance can cause added stress if system response is fast Shunt- and series-wound motors can generate back emf's that are considerably more than the total supply voltage resulting in even higher peak dissipation than a permanentmagnet motor having the same locked-rotor resistance VOLTAGE REGULATOR DISSIPATION The pass transistor dissipation of a voltage regulator is easily determined in the operating mode Maximum continuous dissipation occurs with high line voltage and maximum load current As discussed earlier ripple voltage can be averaged if peak ratings are not exceeded however a higher average voltage will be required to insure that the pass transistor does not saturate at the ripple minimum Conditions during start-up can be more complex If the input voltage increases slowly such that the regulator does not go into current limit charging output capacitance there are no problems If not load capacitance and load characteristics must be taken into account This is also the case if automatic restart is required in recovering from overloads Automatic restart or start-up with fast-rising input voltages cannot be guaranteed unless the continuous dissipation rating of the pass transistor is adequate to supply the load current continuously at all voltages below the regulated output voltage In this regard the LM12 performs much better than IC regulators using foldback current limit especially with high-line input voltage above 20V 11

TL H 8704 ­ 26

The instantaneous power dissipation over the conducting half cycle of one output transistor is shown here Power dissipation is near zero on the other half cycle The output level is that resulting in maximum peak and average dissipation Plots are given for a resistive and a series RL load The latter is representative of a 4X loudspeaker operating below resonance and would be the worst case condition in most

Application Information (Continued)
POWER LIMITING case temperature is almost entirely dependent on heat sink design and the mounting of the IC to the heat sink

TL H 8704 ­ 27

Should the power ratings of the LM12 be exceeded dynamic safe-area protection is activated Waveforms with this power limiting are shown for the LM12 driving g 26V at 30 Hz into 3X in series with 24 mH (i e 45 ) With an inductive load the output clamps to the supplies in power limit as above With resistive loads the output voltage drops in limit Behavior with more complex RCL loads is between these extremes Secondary thermal limit is activated should the case temperature exceed 150 C This thermal limit shuts down the IC completely (open output) until the case temperature drops to about 145 C Recovery may take several seconds POWER SUPPLIES Power op amps do not require regulated supplies However the worst-case output power is determined by the low-line supply voltage in the ripple trough The worst-case power dissipation is established by the average supply voltage with high-line conditions The loss in power output that can be guaranteed is the square of the ratio of these two voltages Relatively simple off-line switching power supplies can provide voltage conversion line isolation and 5-percent regulation while reducing size and weight The regulation against ripple and line variations can provide a substantial increase in the power output that can be guaranteed under worst-case conditions In addition switching power supplies can convert low-voltage power sources such as automotive batteries up to regulated dual highvoltage supplies optimized for powering power op amps HEAT SINKING A semiconductor manufacturer has no control over heat sink design Temperature rating can only be based upon case temperature as measured at the center of the package bottom With power pulses of longer duration than 100 ms

TL H 8704 ­ 28

The design of heat sink is beyond the scope of this work Convection-cooled heat sinks are available commercially and their manufacturers should be consulted for ratings The preceding figure is a rough guide for temperature rise as a function of fin area (both sides) available for convection cooling Proper mounting of the IC is required to minimize the thermal drop between the package and the heat sink The heat sink must also have enough metal under the package to conduct heat from the center of the package bottom to the fins without excessive temperature drop A thermal grease such as Wakefield type 120 or Thermalloy Thermacote should be used when mounting the package to the heat sink Without this compound thermal resistance will be no better than 0 5 C W and probably much worse With the compound thermal resistance will be 0 2 C W or less assuming under 0 005 inch combined flatness runout for the package and heat sink Proper torquing of the mounting bolts is important Four to six inch-pounds is recommended b Should it be necessary to isolate V from the heat sink an insulating washer is required Hard washers like berylium oxide anodized aluminum and mica require the use of thermal compound on both faces Two-mil mica washers are most common giving about 0 4 C W interface resistance with the compound Silicone-rubber washers are also available A 0 5 C W thermal resistance is claimed without thermal compound Experience has shown that these rubber washers deteriorate and must be replaced should the IC be dismounted ``Isostrate'' insulating pads for four-lead TO-3 packages are available from Power Devices Inc Thermal grease is not required and the insulators should not be reused

12

Definition of Terms
Input offset voltage The absolute value of the voltage between the input terminals with the output voltage and current at zero Input bias current The absolute value of the average of the two input currents with the output voltage and current at zero Input offset current The absolute value of the difference in the two input currents with the output voltage and current at zero Common-mode rejection The ratio of the input voltage range to the change in offset voltage between the extremes Supply-voltage rejection The ratio of the specified supply-voltage change to the change in offset voltage between the extremes Output saturation threshold The output swing limit for a specified input drive beyond that required for zero output It is measured with respect to the supply to which the output is swinging Large signal voltage gain The ratio of the output voltage swing to the differential input voltage required to drive the output from zero to either swing limit The output swing limit is the supply voltage less a specified quasi-saturation voltage A pulse of short enough duration to minimize thermal effects is used as a measurement signal Thermal gradient feedback The input offset voltage change caused by thermal gradients generated by heating of the output transistors but not the package This effect is delayed by several milliseconds and results in increased gain error below 100 Hz Output-current limit The output current with a fixed output voltage and a large input overdrive The limiting current drops with time once the protection circuitry is activated Power dissipation rating The power that can be dissipated for a specified time interval without activating the protection circuitry For time intervals in excess of 100 ms dissipation capability is determined by heat sinking of the IC package rather than by the IC itself Thermal resistance The peak junction-temperature rise per unit of internal power dissipation above the case temperature as measured at the center of the package bottom The dc thermal resistance applies when one output transistor is operating continuously The ac thermal resistance applies with the output transistors conducting alternately at a high enough frequency that the peak capability of neither transistor is exceeded Supply current The current required from the power source to operate the amplifier with the output voltage and current at zero

Equivalent Schematic (excluding active protection circuitry)

TL H 8704 ­ 29

13

LM12 80W Operational Amplifier

Physical Dimensions inches (millimeters)

4-Lead TO-3 Steel Package (K) Order Number LM12CLK NS Package Number K04A

LIFE SUPPORT POLICY NATIONAL'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMICONDUCTOR CORPORATION As used herein 1 Life support devices or systems are devices or systems which (a) are intended for surgical implant into the body or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user
National Semiconductor Corporation 1111 West Bardin Road Arlington TX 76017 Tel 1(800) 272-9959 Fax 1(800) 737-7018

2 A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness

National Semiconductor Europe Fax (a49) 0-180-530 85 86 Email cnjwge tevm2 nsc com Deutsch Tel (a49) 0-180-530 85 85 English Tel (a49) 0-180-532 78 32 Fran ais Tel (a49) 0-180-532 93 58 Italiano Tel (a49) 0-180-534 16 80

National Semiconductor Hong Kong Ltd 13th Floor Straight Block Ocean Centre 5 Canton Rd Tsimshatsui Kowloon Hong Kong Tel (852) 2737-1600 Fax (852) 2736-9960

National Semiconductor Japan Ltd Tel 81-043-299-2309 Fax 81-043-299-2408

National does not assume any responsibility for use of any circuitry described no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications