CTV2002 05 02
Month of Issue: Classification:
TELEVISION TECHNICAL BULLETIN
MODELS 56FW53H 76FW54H 66FW53H 66GF63H 76FW53H 66GF64H
May 2002 White Page 1 of 3
66FW54H 76GF64H
REASON
Upgrade of defective opto-coupler .
ACTION
Replace the following parts noting the different pinout of the optocoupler
REF NO IC705 IC703 IC704 IC1703 R724 R750 R711 R1017
Old Part No. RH-FX0106BMZZ* RH-FX0110BMZZ* RH-FX0112BMZZ* *Any of the listed part Nos. may be fitted VRS-TQ2BD271J VRS-TV1JD105J VRS-TV1JD182J VRS-TV1JD122J
New Part No. RH-FX0113BMZZ " " " VRS-TQ2BD221J VRS-TV1JD334J VRS-TV1JD122J VRS-TV1JD102J
PRICE CODE AD AD AD AA AA AA AA
The required parts have been prepared into a kit and can be ordered using the following part number REF NO --DESCRIPTION Parts kit PART NUMBER GF/FWOPTOKIT PRICE CODE AE
Please note This 4 pin device replaces the 6 pin device. Pins 1 and 2 are the same but pins 3 and 4 are the equivalent of pins 4 and 5. This requires that the new opto-coupler is fitted Diagonally. Please see the diagrams on page 2 and 3 to illustrate this.
Sharp Electronics (UK) Limited
Reference JR21052002-1 Revision 1
White Carry out as required Yellow Carry out as required and whenever the unit comes in for service Red Carry out on all units
CTV2002 05 02
Month of Issue: Classification:
TELEVISION TECHNICAL BULLETIN
May 2002 White Page 2 of 3
Please note the positioning of the opto couplers in the case of IC705 (power) above and the data opto couplers (IC703 and IC704)
Sharp Electronics (UK) Limited
Reference JR21052002-1 Revision 1
White Carry out as required Yellow Carry out as required and whenever the unit comes in for service Red Carry out on all units
CTV2002 05 02
Month of Issue: Classification:
TELEVISION TECHNICAL BULLETIN
May 2002 White Page 3 of 3
Please note the positioning in the case of the Dolby Power supply.
Sharp Electronics (UK) Limited
Reference JR21052002-1 Revision 1
White Carry out as required Yellow Carry out as required and whenever the unit comes in for service Red Carry out on all units