Text preview for : AN8037.pdf part of Panasonic AN8037 AN8027, AN8037 AC-DC switching power supply control IC with standby mode



Back to : AN8037.pdf | Home

Voltage Regulators

AN8027, AN8037
AC-DC switching power supply control IC with standby mode
s Overview
The AN8027 and AN8037 are ICs developed for selfexcited switching regulator of RCC local resonance control type. These ICs are designed to achieve stability and high efficiency over a wide input voltage range and loads range (light loads to heavy loads), for supporting input levels used worldwide and improved conformance with energy conservation laws.
2.4±0.25 6.0±0.3 3.3±0.25

Unit: mm

8
0.5±0.1

7
23.3±0.3

6 5 4

1.5±0.25 1.5±0.25 1.4±0.3

s Features

· Support improved conformance with energy conservation laws by providing two operating modes. 0.3 +0.1 ­0.05 · Standby mode (light loads): 3.0±0.3 Achieves better efficiency due to reduced frequency . · Normal mode: SIP009-P-0000C Achieves high efficiency in RCC local resonance operation with zero-cross detection. · Incorporating an input voltage compensation function available to a wide input range for worldwide use. · This function compensates the maximum on-period in inverse proportion to the input voltage. · Incorporating a timer latch function. · The time period can be adjusted according to the overload in normal mode or standby mode. · This function makes it possible to protect the IC from damage that may be caused by the short-circuiting of the IC's external capacitor for the timer. · Incorporating an overvoltage protection function. (detects at VCC pin) · Incorporating a pulse-by-pulse overcurrent protection function, which makes latch protection possible at the time of the short-circuiting of the transformer's primary winding. · Adopting a 9-pin single inline package (E-9S: available to manufacturing in overseas). · AN8027: Transformer resetting is detected from the high- or low-level signal on the TR pin. · AN8037: Transformer resetting is detected from the falling edge of the high-level signal on the TR pin. Refer to the "[1] operation descriptions 7. local resonance operation" section in the application notes.

2 1

s Applications
· Televisions, VCRs, facsimiles, and printers

30°

3

2.54

9

1

AN8027, AN8037
s Block Diagram
7 V CC

Voltage Regulators

OVP SD 8 Timer

3.8 V

S R (SD latch) Q

INIT

Start Stop

VREF

7.1 V

0.5 V

Current reviser (IFB) High-side clamp
Q Q Q Q Q
In In

OCP 2

Out Drive

6 Out 5 GND

Q

FB 9

I/V conv.
(0.7 V)

VFB TON TOFF

CF latch
Q S R R - 0.2 V

4

TR 1

High-side clamp Low-side clamp
(- 0.15 V)

Current reviser (ITR)
0.35 V

CLM

1.0 V

One shot

Start pulse

To timer

s Absolute Maximum Ratings
Parameter Supply voltage Constant output current Peak output current TR pin allowable application current OCP pin allowable application voltage CLM pin allowable application voltage SD pin allowable application voltage FB pin allowable application current Power dissipation (Ta 25°C) Power dissipation (Ta = 85°C) Operating ambient temperature Storage temperature *
*

Symbol VCC IOUT IOP ITR VOCP VCLM VSD IFB PD

CF 3

Rating 24 ±150 ±1 000 ±5 - 0.3 to +7.0 - 0.3 to +7.0 - 0.3 to +7.0 0 to -2.0 874 454 -30 to +85 -55 to +150

Unit V mA mA mA V V V mA mW mW °C °C

Topr Tstg

Note) 1. *: Except for the operating ambient temperature and storage temperature, all ratings are for Ta = 25°C. 2. Do not apply external currents or voltages to any pins not specifically mentioned. For circuit current, '+' denotes current flowing into the IC, and '-' denotes current flowing out of the IC.

s Recommended Operating Range
Parameter Supply voltage Symbol VCC Range From the stop voltage to the OVP supply voltage Unit V

2

Voltage Regulators
s Electrical Characteristics at VCC = 18 V, Ta = 25°C
Parameter Symbol Conditions Min 13.4 7.7 19.4 3.5 0.4 0.05 SD pin = Open 1.0 7.3 VCC = 18 V, VSD = 0 V VCC = 10 V, VSD = 4.3 V Open VCC = 18 V, VSD = 4.3 V Open FB pin = Open, ITR = -270 µA FB pin = Open, ITR = -1.64 mA ITR = -1 mA, ROCP = 30 k 3.0 1.2 3.6 68 179

AN8027, AN8037

Typ 14.9 8.6 20.5 3.9 0.8 0.15 1.5 8.1 4.0 1.5 4.5 102 267

Max 16.4 9.5 21.6 4.3 1.2 0.3 2.0 8.9 5.0 1.8 5.4 136 355

Unit V V V V V V V V mA mA mA µA µA mA V V V mV V V V µA µA

Low voltage protection (U.V.L.O.) VCC-START initial startup supply voltage Low voltage protection (U.V.L.O.) VCC-STOP operation stop supply voltage Overvoltage protection (OVP) operating supply voltage Overvoltage protection (SD) operating threshold voltage Overvoltage protection (SD) reset threshold voltage Remote (RM) operating threshold voltage Shutdown (SD) standby voltage Overvoltage protection (OVP) reset supply voltage Remote (RM) operating time circuit current Overvoltage protection (SD) operating time circuit current 1 Overvoltage protection (SD) operating time circuit current 2 Timer latch (SD) charge current 1 Timer latch (SD) charge current 2 Timer latch (SD) start feedback current Transformer reset detection (TR) threshold voltage Transformer reset detection (TR) upper limit clamp voltage Transformer reset detection (TR) lower limit clamp voltage Overcurrent protection (CLM) threshold voltage Oscillator (CF) upper limit voltage Oscillator (CF) lower limit voltage 1 Oscillator (CF) lower limit voltage 2 Oscillator (CF) maximum on-period current gain Oscillator (CF) maximum on-period current Oscillator (CF) minmum off-period current 1 VCC-OVP VTH1-SD VTH2-SD VTH1-RM VSTB-SD VCC-OVPC ICC-RM ICC1-SD ICC2-SD ISD1-TIM ISD2-TIM IFB-TIM VTH-TR VCLH-TR VCLL-TR VTH-CLM VH-CF VL1-CF VL2-CF GION-CF ION-CF IOFF1-CF FB pin = Open, CF = 2 200 pF FB pin = Open, CF = 2 200 pF IFB = - 0.5 mA, CF = 2 200 pF FB pin = Open, ITR = -750 µA ITR = 0 mA IFB = - 0.4 mA ITR = 3 mA ITR = -3 mA

- 0.95 - 0.75 - 0.55 0.15 0.55 0.25 0.7 0.35 0.85 0 -180 4.6 1.2 0.3 1.2 300 -440

- 0.3 - 0.15 -220 3.8 0.8 0 0.8 200 -880 -200 4.2 1.0 0.1 1.0 250 -660

3

AN8027, AN8037
s Electrical Characteristics at VCC = 18 V, Ta = 25°C (continued)
Parameter Oscillator (CF) minmum off-period current 2 Minimun off-period threshold feedback current Overcurrent protection (OCP) pin source current Output oscillator frequency Symbol IOFF2-CF IFB-TOFF IOCP-OCP FOSC CF = 2 200 pF, ITR = 475 µA, IFB = - 0.5 mA VCC = 13.5 V, IOUT = 1 mA IOUT = 0.1 A IOUT = - 0.1 A VCC = 13.5 V Conditions IFB = - 0.8 mA

Voltage Regulators

Min -210

Typ -160

Max -110

Unit µA mA µA kHz V V V µA mA mA µA

- 0.78 - 0.6 - 0.42 -130 50 15.5 75 8.5 9.0 -100 65 1.0 0.9 16.3 100 11.5 12.0 200 -70 80 1.25 2.0 125 14.5 15.0 380

Pre-startup low-level output voltage VOL-STB Low-level output voltage High-lebel output voltage Pre-startup circuit current 1 Circuit current 1 Circuit current 2 Circuit current durring startup 1 · Design reference data VOL VOH ICC-STB1

ICC1-OPR1 VCC = 10 V ICC2-OPR2 VCC = 18 V ISTART1

Note) The characteristics listed below are theoretical values based on the IC design and are not guaranteed.

Parameter Low voltage protection (U.V.L.O.) start/stop supply voltage difference Remote (RM) reset threshold voltage Timer latch (SD) overcurrent protection time Transformer reset detection (TR) threshold hysteresis width Maximum on-period Minimum off-period Overcurrent protection (OCP) power-on charge period Overcurrent protection (OCP) power-off charge period Output rise time Output fall time TR output response time CLM output response time Pre-startup circuit current 2 Only for AN8037 Timer period during startup 4

Symbol VCC VTH2-RM TCLM-SD VTH-TR TON(max) TOFF(min)

Conditions

Min

Typ 6.3 0.1 0.1 0.05 26.5 5 1.8 8.8 60 20 800 100 100

Max 150

Unit V V s V µs µs µs µs ns ns ns ns µA

ITR = 0 mA, IFB = - 0.2 mA ITR = 0 mA, IFB = - 0.2 mA



TSD(ON)-OCP IFB = - 0.5 mA, ROCP = 22 k TSD(OFF)-OCP IFB = - 0.5 mA, ROCP = 30 k tr tf TTR TCLM ICC-STB2 VCC = 13.5 V, Ta = -30°C to +85°C 10% to 90%, IOUT = 0 mA 10% to 90%, IOUT = 0 mA

50

TSTART



100



µs

Voltage Regulators
s Pin Descriptions
Pin No. Pin name 1 TR I/O I Explanation Transformer reset detection input. When the IC detects transformer resetting and the falling edge of a high-level signal is input to this pin of the AN8037 or a low-level signal is input to the same pin of the AN8027, the level of the Out pin becomes high. However, the transformer reset signal is ignored if the signal is shorter than the minimum off-period determined by the CF pin. Also note that the maximum on-period is corrected according to the source currents. Connection for the resistor that determines the overload level of the IC to activate the timer latch protection circuit. By judging the operating mode (i.e., the normal or standby mode) of the IC from the secondary side, the timer period is adjusted with the selection of external resistance according to the operating mode. Connection for the capacitor that determines the on- and off-periods of the IC output (Out). The on- and off-periods are corrected by ION which is proportional to the flowing out current at the TR pin, and IOFF which corresponds to the current at FB pin.

AN8027, AN8037

Equivalent Circuit

VREF

1 High-side Low-side clamp clamp

2

OCP



VREF

Comp.

CF 2

3

CF



VREF IOFF
Comp.

VFB ION 3

4

CLM

I

Input to the pulse-by-pulse overcurrent protection circuit. Normally, we recommend adding an external filter for this input. If overcurrent continues for several cycles, the IC determines that the operation is erroneous, thus triggering the latch protection function. IC ground.

VREF
Comp.

CLM(-) 4

5

GND



5

5

AN8027, AN8037
s Pin Descriptions (continued)
Pin No. Pin name 6 Out I/O O Explanation Output used to directly drive a power MOSFET. A totem pole structure is adopted in this output circuit. The absolute maximum ratings for the output current are: Peak: ±1 A DC: ±150 mA

Voltage Regulators

Equivalent Circuit

VCC

6

7

VCC



Power supply. This pin monitors supply voltage and has the threshold for the start, stop, OVP, and OVP reset levels. This pin is used in RM (remote), OVP (overvoltage protection), and timer latch. RM: The IC is in remote operation if this pin is short-circuited to the ground and the output of the IC is turned off. OVP: When overvoltage signal of the power supply is detected and high is inputted to the terminal, it turns off the internal circuit. At the same time, it holds that condition (latch). Timer latch: It detects the output voltage fall due to the overcurrent condition of the power supply output through the current level inputted to FB. When the IFB decreases under the current of certain value, the charge current flows in the capacitor which is connected to this terminal. Then, when the capacitor is charged up to the threshold voltage of the OVP, the OVP works so that the IC could keep the operation stop condition. Connection for the photocoupler used for the power supply output error-voltage feedback. This input can decrease the photocoupler dark current by about 200 µA.

7

8

SD

I

VCC OVP
Comp.

3.9 V ITIM 8

RM
Comp.

0.1 V

25 µA

9

FB

I

VREF VFB

IFB 9

6

Voltage Regulators
s Application Notes
[1] Operation descriptions 1. Start/stop circuit block · Startup mechanism After the AC voltage is applied and the supply voltage due to the current in the startup resistor reaches the startup voltage and the IC begins to operate, drive of the power MOSFET begins. This causes a bias in the transformer, and the supply voltage is provided to the IC from the bias winding. (This is point a in figure 1.) During the period between the point when the startup voltage is reached, and the point when the bias winding can generate a voltage enough to supply the IC, the IC supply voltage is provided by the capacitor (C8) connected to VCC. Since the supply voltage falls during this period (area b in figure 1), if the supply voltage falls below the IC stop-voltage before an adequate supply voltage can be provided by the bias winding, it will not be possible to start the power supply. (This is the state at point c in figure 1.) Rectified AC Startup resistor R1

AN8027, AN8037

VCC C8 VOUT GND

Standby Startup voltage Stop voltage a

Startup Voltage supplied from bias winding Startup state b c Startup failure

Figure 1 · Functions This IC includes a function that monitors the VCC voltage. It starts IC operation when VCC reaches the startup voltage (14.9 V typical), and stops operation when the voltage falls below the stop voltage (8.6 V typical). Since a large voltage difference (6.3 V typical) is taken between the start and stop voltages, it is easy to select values for the start resistor and the capacitor connected to VCC .
Note) To start up the IC operation, the startup current which is a pre-start current plus a circuit drive current is necessary. Set the resistance value so as to supply a startup current of 400 µA.

2. Oscillation circuit The oscillation circuit makes use of the charge and discharge of current to and from the capacitor CCF connected to the CF pin (pin 3) to determine the switching timing of the power MOSFET. The IC is in constant voltage control by changing the on-period of the power MOSFET without making offperiod change while the IC is in normal (RCC continuous) operation mode. At that time, the on-period is controlled by directly changing the output pulse width of the oscillation circuit, and the maximum on-period can be adjusted with input voltage compensation by detecting the input voltage with the flow of current from the TR pin (TR source current). Refer to figure 2. When the IC is in standby mode (for light loads), the stable, efficient control of the IC is ensured by detecting the flow of current from the FB pin (IFB) and changing the off-period for a decrease in frequency. Refer to figure 3. The following provides information on how to set on- and off-period. · Setting the on-period The output on-period is the discharge period when the CF pin is between the peak value oft VH-CF = 4 V (typical) and VFB . An approximate on-period of the power MOSFET is obtained from the following formula. Refer to figure 2. TON = CCF × (VH-CF - VFB)/ION whereas, VH-CF = 4 V typ. ION = ITR + 250 µA typ. ITR = (EIN × NB/NP - VZ)/RTR VFB = 0.7 V typ. (IFB 200 µA) VFB = 4 k × IFB typ. (IFB > 200 µA) 7

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued) 2. Oscillation circuit (continued) · Setting the on-period (continued) TON : On-period CCF : Value of a capacitor connected to CF pin VFB : Voltage internally converted from feedback signal IFB VH-CF : CF upper limit voltage ION : On-period discharge current ITR : Flowing current at TR pin EIN : Voltage on primary winding NB : Number of turns in the bias winding NP : Number of turns in the primary winding VZ : Voltage on Zener diode connected to bias winding RTR : Value of a resistor connected to the TR pin

Voltage Regulators

The power MOSFET is turned off if the voltage at the CLM pin reaches the pulse-by-pulse overcurrent protection threshold voltage (i.e., -200 mV typical) when the overcurrent protection function of the IC is operating. TON is shortened NP EIN+ because large EIN
increases ITR.

ITR

RTR

VZ VCC NB

AN8027, AN8037 TR IFB PC FB
Current mirror Current mirror

ITR=ION

1:5 20 k VFB 250 µA typ.
CF

ION

Out GND EIN-

The minimum current is guaranteed to prevent a limitless increase in TON .

CCF EIN; large ITR(ION); large

VH-CF = 4 V
CF pin voltage

VFB 0V VCC - 1.5 V
Out pin voltage

Off 0V

On

Figure 2. On-period block diagram and control waveform
The maximum on-period can be used for overcurrent protection. When the input voltage is low, the maximum on-period overcurrent protection is possible. When the input voltage is high, the CLM pulse-by-pulse overcurrent protection is possible. 8

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued)

AN8027, AN8037

2. Oscillation circuit (continued) · Setting the off-period The minimum off-period is the charge period from VL-CF = 0.2 V (typical) to VTH(OFF) or VFB . An approximate minimum off-period of the power MOSFET is obtained from the following formula. Refer to figure 3. TOFF(min) = CCF × VTH(OFF) /IOFF1 (IFB 0.6 mA) = {CCF × VTH(OFF) / IOFF1} + {CCF × (VFB - VTH(OFF)) / IOFF2} (IFB > 0.6 mA) VTH(OFF) = 2.4 V typ. IOFF1 = 660 µA typ. IOFF2 = 160 µA typ. TOFF(min) : Minimum off-period CCF : Value of a capacitor connected to the CF pin VFB : Voltage internally converted from feedback signal IFB VTH(OFF) : Threshold voltage of VFB to extend off-period IOFF1 : Charge current until CF pin voltage increases from 0.2 V to 2.4 V IOFF2 : Charge current until CF pin voltage increases from 2.4 V to VFB When the IC is in local resonance operation, the off-period is determined by the longer one of either the time required for the input voltage on the TR pin to drop below the threshold voltage or the minimum offperiod (TOFF(min)) specified by the CCF. Thus the power MOSFET is in continuous on/off operation. EIN+ AN8027, AN8037
Current mirror

NP

VCC

NB

PC

FB

1:5 20 k
OFF VFB (I < 0.6 mA) FB

I

= 660 µA typ.

IOFF

Out GND

IOFF = 160 µA typ. (IFB > 0.6 mA)

CF
CCF VH-CF = 4 V
CF pin voltage

IFB < 0.6 mA

VH-CF = 4V
CF pin voltage

IFB > 0.6 mA VFB IFB; large TOFF(min); large

VTH(OFF) = 2.4 V VL2-CF = 0.2 V 0V VCC - 1.5 V
Out pin voltage

VFB

VTH(OFF) = 2.4 V VL2-CF = 0.2 V 0V VCC - 1.5 V

TOFF(min) TOFF

On

Out pin voltage

TOFF(min) TOFF

On

0V

0V

Figure 3. Off-period block diagram and control waveform 9

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued) 3. Control waveform timing chart 1) Normal (RCC contiuous) operation mode

Voltage Regulators

0V
(A)Voltage on bias winding
Off On Off On Off On Off

(B)TR pin voltage

0V
Input voltage correction

EIN; large TON; short

4V
(C)CF pin voltage

VFB voltage 2.4 V

0V VCC - 1.5 V
(D)Out pin voltage
Off On Off On Off On

IFB correction VFB; large TOFF(min); long

Off

0V
(E)Current on primary winding

Current on bias winding

(F)Current on secondary winding

0A

Heavy

Load

Light

(B) TR VCC AN8027, AN8037 Out CLM CF (C) (G) (E) (F)

(A) (D)

10

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued) 3. Control waveform timing chart (continued) 2) Standby (Intermittent) mode (for light loads)
On

AN8027, AN8037

0V
(A)Voltage on bias winding
Off Off Off

(B)TR pin voltage

0V

TON is acceptable only after CF pin voltage reaches 4 V.

4V VFB voltage 2.4 V
(C)CF pin voltage TOFF(min) T(OFF)
TON is unacceptable during TOFF(min) period.

0V
On On

(D)Out pin voltage
Off Off Off

0V

Current on bias winding

(E)Current on primary winding

(F)Current on secondary winding

0A

(B) TR VCC AN8027, AN8037 Out CLM CF (C) (G) (E) (F)

(A) (D)

11

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued) 3. Control waveform timing chart (continued) 3) Pulse-by-pulse overcurrent protection (CLM) operation

Voltage Regulators

0V
(A)Voltage on bias winding
Off On Off On Off On Off On Off

(B)TR pin voltage

0V

(E) Current on primary winding

0A 0V

(H)CLM pin voltage

- 0.2 V
CLM threshold voltage

4V
(C)CF pin voltage

2.4 V

VFB voltage 0V VCC - 1.5 V
(D)Out pin voltage
Off On Off On Off On Off On Off

0A

(B) TR VCC AN8027, AN8037 Out CLM CF (C) (G) (E) (F)

(A) (D)

12

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued)

AN8027, AN8037

4. Power supply output control system (IFB: feedback) Constant-voltage control of the power supply output is performed by changing the on- and off-period of the power MOSFET. The on- and off-period are controlled with the photocoupler connected to the FB pin (Pin 9). The photocoupler adjusts the current at the FB pin according to the signal that is output from the output voltage detection circuit on the secondary side and changes the VFB voltage. Refer to figure 4. The higher the AC input voltage is and the lower the load current is, the higher the current flow from FB pin, the higher the VFB voltage, and the shorter the on-period (or longer the off-period in standby mode) will be. Note that a current cancellation capacity of about 200 µA is provided to compensate for the dark current of the photocoupler. Refer to figure 5.
AN8027, AN8037 7.1 V 1:5 200 µA typ. VFB 20 k
Soft start current is discharged when the IC is not in operation.

Power output on secondary side PC
A minimum of 1 mA is required for biasing the AN1431T/M.

9 FB PC Primary side

AN1431T/M

Secondary side

Figure 4. Power output control
VFB (V)
5

4

3

2

Dark current

1

0

0

- 0.2

- 0.4

- 0.6

- 0.8

-1.0

IFB (mA)

Figure 5. Feedback current vs. VFB characteristics 5. Soft start When a power supply is started, it starts up in an overload state due to the capacitor connected to the power supply output. At that moment, the output voltage is low. Therefore, the IC in usual voltage regulation tries to start up the power output circuit at a maximum duty cycle. Although the IC tries to limit the current by the pulse-bypulse overcurrent protection at the CLM pin, the pulses cannot be suppressed to zero due to delays caused by the filter. As a result, high current flows to the main switch (i.e., power MOSFET) and to the diode on the secondary side. Therefore, in the worst case, these components are totally broken. To prevent this, soft start is used to suppress inrush currents at power supply startup. 13

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued) 5. Soft start (continued) As shown in figure 6, connect R3 and C4 between the FB pin (Pin 9) and GND pin (Pin 5) so that the switching regulator will be in soft start operation. When the voltage supplied to the IC reaches the start voltage and the operation of the startup circuit begins, an open bias voltage of approximately 6.4 V is output to the FB pin. As a result, the charge current IFB flows into C4 from the FB pin. Then the switching regulator starts up at high VFB, thus performing output control while the TON period is short. The voltage difference between both edges of C4 rises according to the time constant determined by R3 and C4, thus decreasing IFB with the lapse of time and increasing the TON period gradually. The above operation increases the flow of current to the power MOSFET gradually after the switching regulator is turned on, thus suppressing the inrush current. However, this reduces the transient response of the feedback loop, so care is required in designing this circuit.
Rectified AC

Voltage Regulators

Startup resistor R1 AN8027, AN8037 VCC C8 FB R3 C4 Out CLM GND To AC - R8 C6 R7 PC1

Figure 6 · Notes on selecting R3 The oscillation circuit of this IC is designed under the condition that the TON period is definite. If excessively low resistance value for R3 is selected, the slope of the triangular wave on the CF pin immediately after the startup may become extremely steep, leading to malfunction of the oscillation circuit. Accordingly, we recommend that you adjust R3 so that the drive pulse width t1 immediately after the startup is 0.5 ms or greater. (Refer to figure 7.) Note that the drive pulse width t1 depends on the capacitance value of the CCF that is connected to the CF pin (Pin 3). Figure 8 indicates recommended values of R3 corresponding to the capacitance value CCF. (In actual mounting conditions, the correlation shown in figure 8 may deviate slightly.)

t1 VOUT (Pin 6)

3 000

VCC = 16 V C4 = 0.033 µF

CF capacitance (pF)

2 000

1 000

CF (Pin 3)
0 10 12 14 16 18 20 22

R3 (k)

Start

Figure 7

Figure 8

14

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued)

AN8027, AN8037

5. Soft start (continued) · Effective period for the soft start The effective period for the soft start with the connection of R3 and C4 to the FB pin is approximately calculated by the following formula. [Approximate formula] tSS = R3 × C4 (s) It is thought that the effectiveness of the above formula is weakened because of the following reason: The voltage difference between both ends of C4 rises up to 63% of the voltage at the FB pin within the time constant (= R3 × C4), resulting in decrease of the charge current IFB, although it depends on the value of R3. Note that if you increase the capacitance value of C4 unnecessarily, it would decrease the sensitivity of the feedback by the photocoupler. · Soft start at the re-startup This IC includes a discharge circuit to instantly discharge charged electrons in the capacitor connected to the FB pin in order to ensure the soft start at the re-startup. Conditions for the operation of the discharge circuit are as follows: 1) VCC has become the stop voltage or below. (at the normal operation) 2) VCC has become the OVP reset threshold voltage or below. (at the OVP operation) 6. Notes on the feedback control If the IC output pin (pin 6) falls to a negative voltage lower than that of the GND pin, the startup operation may fail or the output oscillation may become unstable. ICs in general, not just this IC, do not respond well when negative voltages lower than the ground level are applied to their pins. (Except for special applications.) This is because parasitic device operations may be induced when negative voltages are applied due to the structure of ICs themselves. In the case mentioned above, when the IC output (VOUT) is turned off, the power MOSFET drain-to-source voltage, VDS, jumps from a low voltage to a high voltage. The voltage chattering that occurs at this time is superposed on VOUT through the parasitic capacitance Cgd between the power MOSFET gate and drain, and generates a negative voltage with respect to the pin. No problems occur if the peak voltage, Vex, of this negative voltage does not exceed the parasitic device conduction voltage (about - 0.7 V). However, the amplitude of the chattering is larger for higher input voltages and for larger leakage inductance in the transformer used. Also, the influence of this phenomenon becomes more noticeable for the larger Cgd of the power MOSFET used, and the Vex peak value also increases. If the parasitic device conduction voltage is exceeded, then, in this IC, the parts of the circuit around the feedback circuit (FB) (in particular, the FB discharge circuit) are influenced. This can cause momentary drops in the FB pin voltage (the control voltage), and as a result increase the FB current IFB and thus does not allow the drive pulse on-period TON to be increased. It may also prevent stabilization of the circuit. These are symptoms of the case described here. (Refer to figures 9 and 10.)

Rectified AC

FB VDS

Cgd Out GND Figure 9

VDS

VOUT GND Vex FB Figure 10 Control voltage

15

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued) 6. Notes on the feedback control (continued)

Voltage Regulators

[Countermeasures] If an application exhibits the symptoms of the case described above, or similar symptoms, first insert a Schottky barrier diode between VOUT and GND. It is not possible to completely remove the mechanism described above from a power supply system. It is also not possible to prevent levels from being pulled down to negative voltages in the control IC itself. Therefore, the most important point in designing countermeasures is to prevent such negative voltages from reaching the parasitic device conductance voltage.
Note) If a Schottky barrier diode is added to the circuit and the condition improves initially but the symptoms reappear when the input voltage or other parameter is increased, try replacing the Schottky barrier diode with one that has a larger forward current (both peak and average values). The current capacity of the Schottky barrier diode is sometime insufficient.

(Reference) The following our Schottky diodes are available. Part No. MA2C700A (MA700A*) MA2C723 (MA723*) MA2C719 (MA719*)
Note) *: Former part number

Reverse voltage 30 V 30 V 40 V

Forward current (average) 30 mA 200 mA 500 mA

Forward current (peak) 150 mA 300 mA 1A

7. Local resonance operation (power MOSFET turn-on delay circuit) Local resonance operation by using the AN8027 or AN8037 is possible with circuits as shown in figure 13. C7 is the resonance capacitor, and R9 and C9 form a delay circuit for adjusting the power MOSFET turn on time. When the power MOSFET is off, the voltage that occurs in the drive winding is input to the TR pin (pin 1) through R9 and C9. The power MOSFET will be held in the off state while a high level (a level higher than the threshold voltage, which is 0.25 V typical) is input to the TR pin. The TR pin also has a clamping capability for upper and lower limit voltages. The upper limit voltage is clamped at 0.7 V (typical) (sink current: -3 mA), and the lower limit voltage is clamped at about - 0.15 V typical (source current: 3 mA). (Refer to figure 11.) The power MOSFET off-period is determined by the longer period of the following two periods: the period until the TR pin input voltage becomes lower than the threshold voltage as the bias winding voltage falls after the transformer discharges its energy, and the minimum off-period (TOFF(min)) stipulated by the internal oscillator. (Refer to the "Setting the off-period" section in the "Operating descriptions, 2. Oscillation circuit.") As a result, ringing in the bias winding does not be regarded as a turn on signal during the minimum off-period.

16

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued) 7. Local resonance operation (power MOSFET turn-on delay circuit) (continued)

AN8027, AN8037

AN8027, AN8037
Not acceptable during TON and TOFF(min) periods. Transformer resetting comparator One shot (AN8037 only) Upper limit clamp 0.7 V typ.

VCC
Lower limit clamp - 0.15 V typ.

DB

NB

TR

RTR

Adjust so that the current will be ±3 mA. Lower limit clamp current

0.25 V typ.

GND
Upper limit clamp current

· Bottom-on function (AN8037 only) A one-shot pulse is generated at the moment the signal level on the TR pin switched to low level from high level reaches 0.25 V (typical) after the turn-on signal is received. Refer to the next section for details.

Figure 11
8. Bottom-on function (AN8037 only) Unlike the AN8027 or our conventional AN8026, AN8028, or AN8029 IC, which detects transformer resetting with the high or low level in comparison to the threshold voltage on the TR pin, the AN8037 detects transformer resetting on the falling edge across the threshold voltage. This ensures the reliable local resonance operation of the IC regardless of input voltage fluctuations in a wide input range for worldwide use, thus eliminating difficulty in turning on the power MOSFET when VDS is close to the minimum value. Refer to figure 12. tpd Transformer resetting tpd detected on falling edge. VP VDS VDS

VP 0V VTR 0.25 V 0V ID VIN VTR 0.7 V typ. 0V VTR 0.25 V 0V ID

VIN

VTR 0.7 V typ.

0V Input voltage; Low Figure 12

0V Input voltage; High

17

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued)

Voltage Regulators

8. Bottom-on function (AN8037 only) (continued) Select the constants of R9 and C9 to determine the turn-on delay time so that the power MOSFET will be turned on at a frequency of half the resonant frequency. Practically, refer to figure 12 and determine the turn-on delay time so that the power MOSFET will be turned on at VDS = 0 V. The approximate resonant frequency can be obtained from the following formula. 1 C: resonant capacitance fSYNC = [Hz] 2 L · C L: inductance of primary winding of transformer The turn-on delay time tpd(ON) to turn on the power MOSFET at a frequency of half the resonant frequency is, therefore, as follows. tpd(ON) = L · C [s] Note that since insertion of the resonance capacitor results in increased losses, using the parasitic capacitance of the power MOSFET itself should also be considered. However, in this case the sample-to-sample variations and temperature variations should be considered. 9. Notes on R9 and C9 value selection If an excessively low value is used for R9, the current flowing into the TR pin after power supply startup will exceed the maximum rating for the IC, and incorrect operation (in the worst case, destruction of the device) may occur. We recommend using a value of R9 in the range that satisfies the following conditions. VB(-) - The TR lower limit clamp voltage (- 0.15 V typical) -3 mA R9 VB(-): negative peak voltage VB(+) - The TR upper limit clamp voltage (1.5 V typical) 3 mA R9 VB(+): positive peak voltage Adjust tPD(ON) with C9 by taking the inductance and resonant capacitance of the transformer into consideration.
tpd VIN Rectified AC R1 7 VCC C8 R9 VB 1 TR SBD C9 VTR 0.25 V 0V 6 Out SBD ID R7 To AC - Figure 13 0V Figure 14 ID C7 VTR 0.7 V typ. 0V VIN VP VDS VP

18

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued)

AN8027, AN8037

10. Output block This IC adopts a totem pole (push-pull) structure output circuit in which NPN transistors as shown in figure 15 sinks and sources current to rapidly drive the power MOSFET which is a capacitive load. This circuit provides maximum sink and source currents of ±0.1 A (DC), and peak currents of ±1.0 A. Furthermore, this circuit has a sink capability of 1 mA (typical) even when the supply voltage has fallen under the stop voltage, and thus can turn off the power MOSFET reliably. The main requirement on the control IC in this type of power supply is the ability to provide a large peak current. That is to say, a high average current is not required in steady state operation. This is because the power MOSFET is a capacitive load, and while a large peak current is required to drive such a load rapidly, once the load has been charged or discharged a much smaller current suffices to retain that state. This IC has a guaranteed peak current capability of ±1 A, values which were determined by considering the capacitance of the power MOSFETs that will be used. The parasitic inductance and capacitance of the power MOSFET can cause ringing, and pull down the output pin below the ground level. If the output pin goes to a negative voltage that is larger than the voltage drop of the diode, this state can turn on the parasitic diode formed by Schottky barrier diode the collector of the output NPN transistor and the substrate. Insert a Schottky barrier diode between the output and ground if this is a problem. (Refer to figure 15.) Figure 15 11. Timer latch The pulse-by-pulse overcurrent protection function by itself cannot fully protect the transformer, the first recovery diode or Schottky diode on the secondary side, or the power MOSFET, if the power output is overloaded or shortcircuited for a certain period. If the overcurrent state continues for a certain period or longer time, the timer latch function makes it possible to interrupt the IC in a certain period by charging the capacitor connected to the SD pin. The overload of the power output or short-circuiting of the power output is monitored as a voltage drop in power output, at which time the pulse-by-pulse overcurrent protection is in operation. The voltage drop in power output is detected as a decrease in current through the FB current feedback pin (pin 9). If this current is less than a certain value, the on-chip comparator of the IC is in inverted operation to provide constant current to the SD pin. Refer to figure 16. Then external capacitor connected to the SD pin is charged and the voltage on the SD pin rises to the SD operating threshold voltage (i.e., 3.9 V typical), overvoltage protection (OVP) is triggered, and the operation of the IC is suspended. Refer to figure 17.
AN8027, AN8037 VCC ISD
Latch

Input voltage correction: Voltage input is detected from the flow of current from the TR pin. ISD = 1 × ITR + 70 µA, n 8.4 n

DB SD
The pin voltage rises by charging the timer to trigger OVP.

NB

OVP On

Shutdown VOVP 3.9 V typ.
Timer capacitor discharging conditions VCC < U.V.L.O. stop voltage VCC < OVP reset voltage

Overcurrent detection VOCP > VFB Timer capacitor discharging transistor

Discharging

Charging

FB PC

IFB

ITIM CTIM

On

GND
The timer period is set according to the capacitance.

Figure 16

19

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued) 11. Timer latch (continued) VO

Voltage Regulators

Power supply stop Power supply output voltage 0 IDS Power MOSFET current 0 VSD VTH1-SD SD pin voltage 0 Figure 17. Basic timer latch operation 12. Setting the timer period The period between the detection of the erroneous power output and the moment OVP is triggered (hereinafter called timer period) needs to be longer than the rise time of the power supply. Since at operation start the IC is in the same condition as the overload or output short-circuit condition, if the timer period is shorter, the power supply works latch and can not start. Therefore, the IC has a design making it possible to adjust the timer period with the external capacitor connected to the SD pin. Make sure, however, that the capacitor is not too high, otherwise the power supply may be damaged.
Charge current is provided from the SD pin within a period when the voltage on the CF pin satisfies the following condition during the on-period.

Time Power supply stop

Time Power supply stop SD = 3.8 V typ. Time

CF pin voltage OCP pin voltage

VOCP = 2.2 V typ. V FB (ROCP = 22 k) Off On

VOCP VCF VFB

Out pin voltage

Timer period input voltage correction

Cycle T
SD pin charge current

ISD

EIN; large ISD; large
Input voltage is detected from the flow of current from the TR pin.

ISD = 1 × ITR + 70 µA, n 8.4 n

Figure 18

20

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued)

AN8027, AN8037

12. Setting the timer period (continued) Timer period (TTIM) is obtained from the following formula. TTIM(S) = {CSD × (VTH1-SD - VSTB-SD)}/ISD(AVE) VTH1-SD = 3.9 V typ. CSD : Capacitor connected to SD pin VSTB-SD = 1.6 V typ. VTH1-SD : Shutdown operating threshold voltage 3.9 V typ. ISD(AVE) = ISD × TSD /T VSTB-SD : Shutdown standby voltage 1.5 V typ. TSD = CCF × (VOCP - VFB)/ION ISD : Timer latch charge current TSD = CCF × (VOCP - VFB)/ION TSD : Timer latch charge period T : Cycle CCF : Capacitor connected to CF pin VOCP : OCP pin voltage = ROCP × 100 µA typ. VFB : Voltage internally converted from feedback signal IFB I = FB × 20 k + VBE 5 I ION : On-period charge current = 250 µA typ. × TR 4 By detecting the overload level on the secondary side from IFB and changing TSD , the timer period can be adjusted according to the overload level. Furthermore, in the application circuit, the timer period can be adjusted in both standby and normal modes. To enable this, let the microcomputer on the secondary side detect the operating mode (i.e., either the standby or normal mode) of the IC to vary the value of the resistor connected to the OCP pin with the photocoupler. Refer to figures 19 and 20.

AN8027, AN8037 I TR
Current mirror

TR VCC DB SD OCP CTIM PC2 GND

NB

ISD = ITR + 70 µA FB IFB PC VFB 20 k
Current mirror

ISD On

IOCP 100 µA

1:5

The timer period is adjusted by detecting the overload level on the secondary side from IFB .

Timer capacitor charging condition The following condition must be satisfied during on-period. VOCP > VFB

The operating mode (i.e., either the standby or normal mode) is detected by the microcomputer on the secondary side and the timer period is adjusted.

Figure 19
Timer period (s) 7 Standby mode Normal operation mode 2 40 Figure 20 70 Load on secondary side (W) (Values are for an example circuit.)

21

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued)

Voltage Regulators

13. Overvoltage protection (OVP) circuit OVP stands for overvoltage protection. The overvoltage protection circuit is a self-diagnostic function that shuts down the power supply to protect the load if a voltage that is significantly and abnormally higher than the normal output voltage occurs in the power supply output, due to, for example, a malfunction in the control system or an abnormal voltage applied externally. (Refer to figure 22.) Basically, the overvoltage protection circuit should be designed so that the VCC pin voltage of the IC can be monitored. Since the VCC pin voltage is normally supplied from the transformer bias winding, this voltage is proportional to the secondary side output voltage. Thus the overvoltage protection circuit operates when an overvoltage occurs in the secondary side output. 1) If, as a result of an abnormality in the power supply output, the voltage input to the VCC pin exceeds the threshold value (20.5 V typical), the IC internal reference voltage is shut down, and all control operation is stopped. The IC then holds this state. If latching at a voltage lower than the threshold value is required, connect a Zener diode between the VCC and SD pins as shown in figure 22 and take method 2) below to set the voltage. 2) If the SD pin input voltage exceeds a threshold value of 3.9 V typical, the IC internal reference voltage is shut down, and all control operation is stopped. The IC then holds this state. 3) OVP is reset in two methods. One is to decrease the output voltage on the secondary side so that the VCC pin voltage is less than the OVP reset voltage, i.e., 8.1 V typical. The other is to decrease the SD pin input voltage (VSD) to a value less than the SD reset voltage, i.e., 0.7 V typical, by external resetting. If VSD is less than 0.1 V typical, however, the IC will be in remote operation to shut off the output. The IC incorporates a circuit that discharges a constant current of approximately 25 mA from the capacitor connected to the SD pin for the re-start operation. The operation of this circuit is stopped when the SD pin voltage drops to 1.5 V or below. Refer to figure 21.
OVP reset conditions VCC < OVP reset voltage VSD < SD reset voltage

AN8027, AN8037

VCC ZOVP SD DB

NB

OVP
Latch Shutdown VOVP-SD 3.9 V typ.
Timer capacitor discharging conditions VCC < U.V.L.O. stop voltage VCC < OVP reset voltage

VOVP-VCC 20.5 V typ.
Timer capacitor discharging transistor

CTIM

On

GND

Figure 21

The following is a formula to allow the IC to be in OVP operation with the SD pin in the above method 2). V(OUT) Secondary side output voltage under normal operation Vth(OUT) = × V7 VCC pin voltage under normal operation V7 = VTH-SD1 + VZ Vth(OUT) : Secondary side output overvoltage threshold value VTH-SD1 : SD operating threshold value VZ : Zener voltage (externally connected to OVP pin)

22

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued)

AN8027, AN8037

13. Overvoltage protection (OVP) circuit (continued) · Operating supply current characteristics When the OVP circuit operates and the power supply current drops, this can induce a rise of the supply voltage VCC . In the worst case, it may exceed the IC's guaranteed breakdown voltage (24 V). Therefore, the circuit is provided with characteristics that cause the supply current to rise in constant resistance mode when the OVP circuit operates, and thus prevent increases in the supply voltage. Due to these characteristics, if the supply voltage VCC when the OVP circuit operates is stabilized at a value (note that this value depends on the value of the startup resistor) that is larger than the OVP release voltage, the OVP circuit will not be reset as long as the AC input is not cut. (Refer to figure 23.) Note that this does not apply to an external reset.

Rectified AC Startup resistor R1 VCC Power output
Abnormal voltage applied from outside.

SD Out GND

Load
Should there be abnormal voltage (i.e., voltage that is higher than the power output voltage and may damage the load) applied to the power output from outside, the IC detects the abnormal voltage through the bias winding on the primary side and triggers OVP.

Figure 22

Rectified AC Startup resistor R1 VCC Out GND

Current is continuously supplied to the VCC pin through the startup resistor as long as voltage is applied to the startup resistor from commercial AC power.

No current is supplied to the VCC pin from this bias winding if OVP is triggered and the output of the IC is stopped. * Select the startup resistor so that the VCC satisfies the following condition according to the current supplied through the startup resistor. VCC > VCC-OVP

ICC

There is a surge of operating current at VCC-OVP (i.e., a voltage that resets overvoltage protection). This prevents VCC from exceeding the absolute maximum rating of the IC caused by a decrease in current supply from the startup resistor.

VCC- OVP

VCC Figure 23

23

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued)

Voltage Regulators

14. Remote on/off function The SD pin of the AN8027 or AN8037 has a remote on/off function besides the following functions. · Timer latch function · Overvoltage protection function The remote on/off function turns the power supply output on and off remotely with external signals. Furthermore, this function turns the power supply off by setting the SD pin voltage extremely close to the ground voltage (i.e., 0 V) if the capacitor connected to the SD pin for timer latch use is damaged in the short-circuit mode. Refer to figure 24.
AN8027, AN8037 8 SD The power supply is turned off if the capacitor is damaged in the short-circuit mode.

Figure 24

On the other hand, a hysteresis width of 50 mV (typical) is provided for threshold SD voltage to prevent the output of the IC in remote operation from chattering. Refer to figure 25.

VSD 0.15 V 0.1 V 0V

VOUT Start Figure 25 Stop

24

Voltage Regulators
s Application Notes (continued)
[1] Operation descriptions (continued)

AN8027, AN8037

15. Overcurrent protection circuit (pulse-by-pulse overcurrent protection) This circuit uses the fact that overcurrents in the power supply output are proportional to the current flowing in the primary side main switch (power MOSFET). This circuit limits overcurrents in the power supply output by constraining the upper limit of the pulse current flowing in the main switch, and thus protects components sensitive to excessive current. The current flowing in the main switch is detected by connecting a resistor between the power MOSFET source and ground and monitoring the voltage that appears across that resistor. When the power MOSFET is turned on and the CLM (current limit) threshold voltage is detected, the output is turned off. This controls the circuit so that a current in excess of that limit cannot flow by turning off the power MOSFET. The CLM threshold voltage is about - 0.2 V typical with respect to ground at Ta = 25°C. While this control operation is repeated every cycle, once an overcurrent is detected, the off state is held for the remainder of that cycle, and the circuit is not turned on until the next period. This type of overcurrent detection Use a capacitor with is called "pulse-by-pulse overcurrent detection." excellent frequency R6 and C6 in figure 26 form a filter circuit that characteristics. R6 R8 rejects noise generated due to the incidental CLM equivalent parasitic capacitance when the power C6 MOSFET is on. For the grounding point, we recommend that GND R7 the power MOSFET source pin and the IC GND Use resistor with pin be connected over as short a distance as pos- To AC - no inductance. sible. Figure 26 · Notes on the detection level precision This overcurrent detection level is reflected on the operating current level of the power supply overcurrent protection function. Therefore, if this detection level varies with sample-to-sample variations or with temperature, the operating current level of the overcurrent protection function of the power supply itself will vary. Since variations in this level imply a need for increased ruggedness in parts used, or even the destruction of circuit components, we have increased the precision of this IC as much as possible. 16. Overcurrent protection circuit (input voltage correction function) As an extended application, this section presents a circuit design that applies a correction so that the overcurrent protection operating point is held fixed with respect to variations in the input voltage. This circuit uses the proportional relationship between the input voltage and the inverted voltage of the bias winding, and superposes inverted voltage of the bias winding on the overcurrent protection operating voltage. (Refer to figures 27 and 28.)
EIN+

VCC AN8027 AN8037
VB

TR
Drs

FB voltage applied; Shutdown FF voltage applied; Correction operation IDS

Out CLM
VCLM Input voltage correction Determines the amount of correction

GND
Rrs

Zrs Determines the input voltage at which correction starts.

EIN- Figure 27

25

AN8027, AN8037
s Application Notes (continued)
[1] Operation descriptions (continued) 16. Overcurrent protection circuit (input voltage correction function) (continued) VDS 0V

Voltage Regulators

VB 0V
Input voltage; larger Amount of correction; larger

FB voltage FF voltage



Input voltage

IDS 0A 0V VCLM

EIN

Correction corresponding to the input voltage

Figure 28 17. Overcurrent protection circuit (Timer latch protection) The CLM pin is used for timer latch in addition to pulse-by-pulse overcurrent protection. This is because the pulse-by-pulse overcurrent protection alone cannot prevent the power MOSFET connected to the Out pin from damage in most cases if the primary winding is short-circuited and excessive current flows to the power MOSFET. If an excessive current flows to the power MOSFET for a certain period due to the short-circuiting of the primary winding, this circuit charges the capacitor connected to the SD pin, shut down the power supply, and holds this state. (Refer to figure 29.) IDS
Winding short-circuiting Power MOSFET current Power supply stop

0 VSD

Time
Power supply stop

VTH1-SD = 3.9 V typ.
SD pin voltage

VSTB-SD = 1.5 V Time

0

Figure 29 [Setting the timer period] The timer period (TCLM) is obtained from the following formula. TCLM = {CSD × (VTH1-SD - VSTB-SD)}/ICLM(AVE) CSD : Capacitor connected to SD pin ICLM(AVE) = ICLM × TOFF /T VTH1-SD : Shutdown operating threshold voltage (ICLM = 100 µA) VSTB-SD : Shutdown standby voltage ICLM : CLM timer charge current (100 µA) Example: If TOFF / T is 50%, CSD is 10 µF. TOFF : Off-period TIM 500 ms T : Cycle 26

Voltage Regulators
s Application Notes (continued)
[2] Package power dissipation
1 000 900 874 800

AN8027, AN8037

PD Ta

Power dissipation PD (mW)

Independent IC without a heat sink Rth j-a = 143°C/W PD = 874 mW (25°C)

700 600 500 400 300 200 100 0 0 25 50 75 100 125 150

Ambient temperature Ta (°C)

s Application Circuit Examples
· Circuit Diagram
100 V C1 0.22 µF /250 V L1 C2 0.1 µF C4 2 200 pF /250 V C3 2 200 pF/250 V C12 2 200 pF L2 D1 C5 180 µF /250 V D6 SBD MA3F760 (MA760*) R1 68 k × 2 D7 SBD MA3F750 (MA750*) C16 1 000 µF/25 V D8 SBD MA3D798 (MA10798*) R8 C9 15 k 3300 pF PC1 100 µF/50 V C10 D2 MA2C166 (MA166*) 9 8 R3 75 k D3 MA2C166 (MA166*) Q2 R5 47 R4 47 C7 2 200 pF FBI Q3 R10 750 R11 510 C15 1.5 µF 6V R12 500 R14 1.8 k 13 V C14 22 µF/50 V 38 V

R19 68 k × 2

C17 1 000 µF PC1

AN1431M/T R13 1.5 k GND

AN8027, AN8037

7 6

C16 10 µF/50 V

S2 5 MA2C700 (MA700*) SBD 4 3 2 1 R9 18 k S1 MA2C700 (MA700*) SBD C11 1 800 pF

C18 22 µF/50 V D9 SBD MA3D760 (MA7D60*) D10 SBD MA3D798 (MA10798*) R6 0.22 C19 47 µF/16 V -30 V

4.6 V

R7 820 R15 51

Q1

Note) *: Former part number

0V

27

28 · Evaluation board chart
FB2 C6 K D FB1 T1 9 10 C17 Z2 R3 D2 R4 R5 D8 A K A Q1 JP R17 D4 PC1 S1 S2 R9 C10 Z1 C16 0.8 9 R8 C13 C11 C7 R15 1 R2 18 K R15 R11 C15 0V A K Q3 R R19 JP C9 R16 R13 N.C. R14 R12 (Adj.) A K D9 D10 R10 A JP GND A C18 C19 30 V 4.6 V C16 G D3 A D7 K A A A 38 V TN2 13 V R6 C5 R7 D5 R18
-

AN8027, AN8037

s Application Circuit Examples (continued)

C8 S Q2

D6

C14

C12

N

C1 Z3

C3

C4

D1

+



6V

TN1

L2

L1

L

JP

Voltage Regulators

AN8027/AN8037 Application Board

R1