Text preview for : TP10AC.pdf part of TOPPOWER TP10AC AC-DC CONVERTERS 10W 4KVAC ISOLATED



Back to : TP10AC.pdf | Home

TP10AC series
DESCRIPTION 10W 4KVAC Isolation Wide Input AC/DC Converters
The rated output power of TP10AC series is 10W,With very low no-load consumption (only 60mW), Low
leakage current(only 0.1mA ),ultra-small size,50.8*25.4*15.5mm,isolated voltage up to 4KVAC. Product
safe and reliable,Good EMC performance,EMC And meet the safety specifications of
IEC/EN61000-4,CISPR22/EN55022,UL60950/EN60950/EN60601,etc.
Widely used in medical, industrial, office and civil industries, if applied to the bad electromagnetic
compatibility must refer to the application circuit


FEATURES




R
Universal input voltage range AC and DC dual-use Wide input voltage: 4:1
Low power consumption High efficiency,high power density, ultra-small size Over current protection, Short circuit protection




E
Low Ripple & Noise RoHS compliant Operating temperature: -40to70
SELECTION GUIDE
Input Voltage Output Efficiency
Part Number (typ.)
VAC VDC Voltage VDC) CurrentA
%




W
TP10AC220S03W 85-265 120-370 3.3 2.00 66
TP10AC220S05W 85-265 120-370 5 2.00 78
TP10AC220S09W 85-265 120-370 9 1.05 80




O
TP10AC220S12W 85-265 120-370 12 0.83 81
TP10AC220S15W 85-265 120-370 15 0.66 82




P
TP10AC220S24W 85-265 120-370 24 0.42 83


All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.




P
INPUT CHARACTERISTICS
Parameter Conditions Mini. Typ. Max. Units
Voltage range DC Input 120 220 370 VDC




O
Voltage range AC Input 85 220 265 VAC
Input frequency 50 60 HZ
Input Current 115VAC 210 mA




T
Input Current 230VAC 100 mA
Inrush current 115VAC 16 A
Inrush current 230VAC 30 A
External fuse recommended value 1A/250V, slow fusing, necessary
Hot plug Unavailable
Leakage current 265VAC/50Hz 0.1 mA
OUTPUT CHARACTERISTICS
Parameter Conditions Mini. Typ. Max. Units
Output voltage accuracy ±2 %
Line regulation ±1 %
Load regulation ±1 %
Short-circuit protection Overvoltage, overcurrent, short circuit protection,self-recovery
Ripple & Noise 20MHz bandwidth (peak-peak value) 50 100 mv
Temperature Coefficient ±0.03 %/
Start rising time 115VAC Input while full-load 200 ms
Start rising time 230VAC Input while full-load 100 ms
Output hold time 115VAC Input while full-load 15 ms
Output hold time 230VAC Input while full-load 40 ms

www.gztoppower.com TEL:0086-20-62162688 Email:[email protected] page 1 of 3
TP10AC series
TEMPERATURE CHARACTERISTICS
Parameter Conditions Mini. Typ. Max. Units
Isolation voltage Tested for 1 min. 4000 VAC
Operating Temperature According to the output load derating curve -40 +70
Storage Temperature -40 +85
Storage Humidity 10 95 % .RH max
Case temperature shall not exceed the maximum case temperature

SAFETY & ELECTROMAGNETIC COMPATIBILITY
Safe standard UL1012,EN60950,EN60601,UL60950,UL60601




R
Isolated voltage I/P-O/P:4000VAC
Isolation resistance I/P-O/P>100M Ohms/500VDC 25 70% RH
Conduction and radiation EN55011, EN55022 (CISPR22) CLASS B




E
Electrostatic discharge( ESD) IEC/EN 61000-4-2 level 4 8kV/15kV
Rf radiation immunity (RF) IEC/EN 61000-4-3
EFT IEC/EN 61000-4-4 level 4 4kV Note: see application circuit for details
Surge IEC/EN 61000-4-5 level 4 2kV Note: see application circuit for details




W
MTBF 200K hrs min. MIL-HDBK-217F(25)
NOTES
1.The above data, except for special instructions, are measured at TA = 25, humidity <75%, input nominal voltage 230Vac and output rated load
2.Ripple and noise are measured according to the application circuit of this manual, using a 300mm twisted pair and in the case of a bandwidth of 20MHz




O
3.The parts in the system is considered as a component, need to combine the terminal equipment for electromagnetic compatibility related confirmation.




P
PRODUCT SCHEMATIC




OP
DERATING CURVE




T
TYPICAL APPLICATION CIRCUIT




www.gztoppower.com TEL:0086-20-62162688 Email:[email protected] page 2 of 3
TP10AC series
NOTES
1. The output filter capacitance C4 is the electrolytic capacitor. It is recommended to use the high frequency low resistance electrolytic capacitance, the capacity and
the current of the flow. Please refer to the technical specifications provided by the manufacturers. Capacitance pressure reduction is greater than 80%. The C5 is to
remove the high frequency noise. D1 is recommended for the TVS tube to protect the rear circuit (when the module is abnormal).
2. The dashed box is an EMC filter that is accessible for higher EMC requirements, which can be omitted while general applications
3.We has formed a filter for C1, C2, C3 and NF ,for the customer to use, the model is FA01.

TYPICAL APPLICATION CIRCUIT
Component
FUSE NTC NF MOV C1 C2C3 C4 C5 D1
PN




R
TP10AC220S03W NF is MOV is 470uF/16V P6KE6.8A
Recomme common the C2,C3 is
TP10AC220S05W C1 is the 470uF/16V P6KE6.8A
nded mode voltage the safety
safety X
TP10AC220S09W T1A external inductance, resistanc Y 150uF/16V 104K/50 P6KE16A
capacita




E
NTC inductance e and the capacitan (Ceramic
TP10AC220S12W /250V nce, 120uF/16V P6KE16A
thermistor, value in recomme ce, capacitors )
104K /
TP10AC220S15W model: 10mH, nded 102K/400 120uF/25V P6KE20A
275V
10d-9 current value is V
TP10AC220S24W 0.2a-0.5 A. 14D471K 100uF/35V P6KE33A




W
MECHANICAL DIMENSIONS

DIP packaging




O
PIN Single
15.50




P
1 N
6.00
2 L




P
3 +V0

2 4 -V0




O
25.40 20.32 bottom view
4
10.16

1 3




T
45.72
50.80




All dimensions in mm ±0.2mm

SELECTION GUIDE
TP 10 A C 220 S 05 W

W:4:1 Wide voltage input range
Main (auxiliary) output voltage
S:single output, D:Dual output
Rated input voltage
Package type
AC-DC
Rated output power
Brand name




www.gztoppower.com TEL:0086-20-62162688 Email:[email protected] page 3 of 3