ALUMINUM ELECTROLYTIC CAPACITORS
WITH CONDUCTIVE POLYMER SOLID ELECTROLYTE PVM
Super low E.S.R. and high ripple current are realized.
Guarantees 105 , 2000 hours .




Marking color Black print
SPECIFICATIONS
Item Performance
Category temperature range ( ) 55~+105
Tolerance at rated capacitance (%) 20 (20 , 120Hz)
Leakage current ( A) Less than 0.2CV
*Note C Rated capacitance ( F) V Rated voltage (V) (20 )
Tangent of loss angle (tan ) Less than 0.12 (20 , 120Hz)
Impedance ratio (max.)
Characteristics at high Z 25 /Z+20 1.15
and low temperature
Z 55 /Z+20 1.25 (120Hz)
Test time 2000 hours
Leakage current The initial specified value or less
Endurance (105 )
Percentage of capacitance change Within 20% of initial value
(Applied ripple current)
Tangent of the loss angle 150% or less of the initial specified value
E.S.R. change 200% or less of the initial specified value
Test time 500 hours
Leakage current The initial specified value or less
Bias Humidity
Percentage of capacitance change Within 20% of initial value
60 , 90 to 95%RH
Tangent of the loss angle 150% or less of the initial specified value
E.S.R. change 150% or less of the initial specified value
The capacitors shall be subject to 1000 cycles each consisting of charge with the surge voltage specified at 105 for
30 seconds through a protective resister (Rc = 1k ) in 6 minutes per cycle. Surge voltage 1.15 times of rated voltage.
Characteristics of applied Leakage current The initial specified value or less
surge voltage Percentage of capacitance change Within 20% of initial value
Tangent of the loss angle 150% or less of the initial specified value
E.S.R. change 150% or less of the initial specified value
Failure tare 1% per 1000 hours maxmum (Confidence level 60% at 105 )
*Note: If any doubt arises, measure the leakage current after following voltage application treatment.
Voltage application treatment: DC rated voltage are appliced to the capacitors for 120 minutes at 105 .