ADJUSTMENT
Common Section
Measurement Adjustment
Test-
Item Condition equipment Unit Terminal Unit Parts Method Specifications/Remarks
1. Setting 1) BATT terminal voltage:7.5V
2) SSG standard modulation
[Wide] MOD:1kHz,DEV:3kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
2. LCD contrast 1) Adj item:[CNTR] [U1] Adjust the LCD contrast by
Adjust:[***] [D1] looking.
Press [P3] key to store the
adjustment value.
3. Counter 1) Adj item:[VOL1] Turn the Volume
clock-wise Adjust:[***] counter-clockwise fully. Press
volume [P3] key to store the
adjustment value.
4. Clock-wise 1) Adj item:[VOL2] Turn the Volume clockwise
volume Adjust:[***] fully. Press [P3] key to store
the adjustment value.
5. Assist voltage 1) Adj item:[RAST] [U1] The display on the left of
[RX] Adjust:[***] [D1] LCD shows PLL lock voltage. 2.5V