HDMI Compliance Test Software
Product: TDSHT3
Version: 3.0.1
Date : 11-January-07
===============================================================
What is in this file:
1. System Requirements
2. Features
3. Known Problems/Issues
4. Installation
5. Starting the Application
6. Contents of Distribution
7. Contact Tektronix
===============================================================
1. System Requirements
- The HDMI Compliance Test Software is compatible with the following instruments:
Product Firmware-Version
========== ==================
TDS7254 2.5.3 or later
TDS7404 2.5.3 or later
CSA7404 2.5.3 or later
TDS7254B 3.0.4 or later
TDS7404B 3.0.4 or later
CSA7404B 3.0.4 or later
TDS7704B 3.0.4 or later
TDS6604B 4.0.4 or later
TDS6804B 4.0.4 or later
TDS6124C 5.0.0 or later
TDS6154C 5.0.0 or later
DPO/DSA 70000 series 3.0.0 or later
- Sun Microsystems' Java Runtime Environment (JRE) version 1.4.2_02 is required
for this release; it will automatically be installed with TDSHT3 if it is
not already present on your oscilloscope. If the JRE is deleted, restore it
through the TDSHT3 installation.
- TekScope firmware updates can be downloaded from the Tektronix website
at http://www.tek.com/Measurement/scopes/index.html.
Under the "Resources" group, click "Software and Drivers".
- The TDSHT3 application requires 256/512MB or more of (windows) system memory.
- Disk space requirements:
~175MB of free disk space to install and operate the application.
- Keyboard:
Save/Recall features require the use of a keyboard to enter file or folder
names.
- Mouse:
Though a mouse is not required, we recommend its use with this
application.
- The best MS Windows(TM) task bar settings for running this application with
a mouse (without a keyboard) is:
Always on top = selected
Auto Hide = selected
- Report Generator Version: 3.01.000 or above
This application will not install Report Generator.
Report Generator is a common feature shared by several applications.
You can install Report Generator from the Optional application CD.
Check the version of Report Generator from Report Generator Help>About.
===============================================================
2. Features
- Conformance to HDMI standards and test specifications (CTS-1.2a) ensures reliable
results
- Complete validation to standards with wide range of tests for Source, Sink,
and Cable devices
- Accurate Source tests by using precise measurement techniques
- Dependable Sink tests with closed-loop measurements that eliminate
non-linearities in test setup
- Shrink test times by automating complex Sink and Cable tests with remote
control of signal sources
- Get quick results with automatic Mask-Fit, measurements, and Pass/Fail
notification
- Get in-depth analysis with statistical analysis and mask margins
- Ensure faster testing with one-button selection of multiple tests
- Save time with one-button csv-format summary and reports
- Complete compliance solution with an elaborate test fixture, signal sources,
and TDR
- HDMI Compliance Test Software also supports the "save and recall setup"feature
- Online help, the PDF of the online help, and Quick Start User Manuals can
be started from:
Start > Programs > TekApplications > TDSHT3 > Help
Start > Programs > TekApplications > TDSHT3 > Help (PDF Version)
Start > Programs > TekApplications > TDSHT3 > Quick Start User Manual
(English)
Start > Programs > TekApplications > TDSHT3 > Quick Start User Manual
(Japanese)
================================================================================
3. Known Limitations
- Before performing any test:
i. Ensure that the probes and test fixtures are connected properly.
ii. It is recommended to do the probe calibration.
If you do not follow the above steps, then the results may be invalid.
- Results: In Eye Diagram and Jitter Plot, if there is no data within a
histogram box, you will see the histogram readout on the plots as "--" and the
histogram will not be displayed. Increase the record length and try again.
- Eye Diagram clipping: If vertical offset of the signal is more than 50% of
the Vswing value, then the eye diagram gets clipped, or in extreme cases, it
might be blank. In such a case, the Result will be shown as conditional pass.
The software will also display a warning message suggesting the user to run
the Overshoot/Undershoot V-H and V-L tests.
- Report remarks/comments: If the remarks/comments are too long,
they might get clipped in the generated report.
- Generated reports can become fragmented during .rtf exporting when
graphics, tables, and result fields close to the right margin are used
in the layout. The default templates provided with this product are
left justified.
- If a printer is not configured on your oscilloscope, you may see a message
box, "You must first configure a printer." when you run the application. Click
OK and then configure a printer.
- In DPO70000 scopes, the Hide button does not bring the instrument application to full
screen. Clicking anywhere in instrument Application will achieve this.
================================================================================
4. Installation
4.1 TDSHT3 (HDMI Compliance Test Software)
By default, the TDSHT3 application resides on the hard drive of your
oscilloscope. If the application is not installed on the hard disk, perform
the following steps to install the application from the Optional
Applications Software on a Windows-Based Oscilloscope Compact disc (CD-ROM):
i. If the keyboard is not installed, connect it to the oscilloscope rear panel
(the optional-accessory keyboard plugs into the USB connector).
ii. Power on the oscilloscope to start Windows.
iii. Install the optional applications software CD in the CD-ROM reader
of the oscilloscope.
iv. The autorun utility will start the installation program. If the autorun
utility does not start up automatically, browse to the CD-ROM and
double-click launch.exe.
v. Click 'HDMI Compliance Test'.
vi. Click 'INSTALL NOW'.
vii. Follow the instructions given by the TDSHT3 InstallShield Wizard.
If Sun Microsystems' Java Runtime Environment (JRE) software is not
previously installed, then the InstallShield Wizard will prompt for
installing it. Follow the instructions to install the JRE. After
successful installation of JRE, choose to restart the oscilloscope
later and continue installing TDSHT3.
viii. When the installation is complete, the InstallShield Wizard asks if
you want to restart the oscilloscope. Click Yes.
ix. Enter the authorized Option Installation Key to enable the application.
The key is specific to the serialized oscilloscope and options for which
it was purchased. To enter the key number, follow these steps:
a. If the oscilloscope is powered on in the toolbar mode (default),
select the Menu button (upper right corner of the display) to
put the oscilloscope into menu-bar mode. In menu-bar mode, you
should see a PC-style menu across the top of the display.
b. Go to the Utilities menu in the menu bar and select Option
Installation.
c. Follow the on-screen instructions to enter the alphanumeric
key number exactly as it is printed on the rear-panel label.
The TDSHT3 application is now ready for use. See "Starting the Application".
4.2 TDSHT3 (DTG Distribution)V1.0.0
The Sink and Cable tests require DTG Patterns on the DTG at -
C:\TekApplications\TDSHT3\Patterns sub-folder. Install the DTG Pattern
files on the Data Timing Generator (DTG 5274).
If the DTG Pattern files are not installed on the DTG hard disk, perform the
following steps to install it from the Optional Applications Software on a
Windows-Based Oscilloscope Compact disc (CD-ROM):
i. If the keyboard is not installed, connect it to the oscilloscope rear panel
(the optional-accessory keyboard plugs into the USB connector).
ii. Power on the DTG to start Windows.
iii. Install the optional applications software CD in the CD-ROM reader
of the DTG.
iv. The autorun utility will start the installation program. If the autorun
utility does not start up automatically, browse to the CD-ROM and
double-click launch.exe.
v. Click 'HDMI Compliance Test'.
vi. Click 'DTG INSTALL'. This will install the DTG Pattern files at -
C:\TekApplications\TDSHT3\Patterns sub-folder on the DTG.
================================================================================
5. Starting the Application
- TDS7254/TDS7404/CSA7404:
On the oscilloscope menu, click File > Run Application > HDMI Compliance Test
Software to start the application. To restore the application, when hidden or
minimized, click the "App" button on the oscilloscope menu.
-TDS7254B/TDS7404B/TDS7704B/CSA7404B/TDS6604B/TDS6804B/TDS6124C/TDS6154C:
On the oscilloscope menu, click App > HDMI Compliance Test Software to start
the application. To restore the App, when hidden or minimized,
click App > Restore Application on the oscilloscope menu.
- DPO70404, DPO70604, DPO70804 , DSA70404, DSA70604, DSA70804:
On the oscilloscope menu, click
Analyze > HDMI Compliance Test Software to start the application.
To restore the application, when hidden or minimized click
Analyze > Restore Application on the oscilloscope.
================================================================================
6. Contents of Distribution
- TDSHT3 (HDMI Compliance Test Software) Software
- Sun Microsystems' Java Runtime Environment (JRE) 1.4.2_02
- TDSHT3 Online help, the PDF of the online help, and Quick Start User Manual
(English and Japanese)
================================================================================
7. Contact Tektronix
For any assistance or feedback on the TDSHT3, please send an email to:
- [email protected] or
- [email protected]
---End of File---