Text preview for : 5992-0193EN M9290A CXA-m PXIe X-Series Signal Analyzer - Configuration Guide c20141015 [12].pdf part of Agilent 5992-0193EN M9290A CXA-m PXIe X-Series Signal Analyzer - Configuration Guide c20141015 [12] Agilent 5992-0193EN M9290A CXA-m PXIe X-Series Signal Analyzer - Configuration Guide c20141015 [12].pdf



Back to : 5992-0193EN M9290A CXA-m | Home

Keysight M9290A
CXA-m PXIe X-Series Signal Analyzer
10 Hz to 3.0, 7.5, 13.6 or 26.5 GHz




Configuration Guide
02 | Keysight | M9290A CXA-m PXIe X-Series Signal Analyzer - Configuration Guide



Overview
This configuration guide contains information to help you configure your M9290A CXA-m
PXIe signal analyzer to meet your requirements. Ordering optional capabilities at time of
purchase provides the lowest overall cost.




Table of contents Page number

Hardware
A: Select options for M9290A CXA-m PXIe signal analyzer ............................................... 3
B: Select controller ................................................................................................................ 4
C: Select a chassis and accessories .. ................................................................................... 6


Physical Connection Diagram for Controllers, Chassis and Accessories ....................... 7


Software
D: Select software for M9290A CXA-m PXIe signal analyzer ............................................. 8


Services
E: Select services: Warranty, calibration, start-up assistance ........................................... 9


Other
Upgrading your system .......................................................................................................... 10
Using an M9290A in a non-Keysight chassis ....................................................................... 10
PC requirements for M9290A control ................................................................................... 11
Related literature ................................................................................................................... 11
03 | Keysight | M9290A CXA-m PXIe X-Series Signal Analyzer - Configuration Guide



Hardware
A. Select options for M9290A CXA-m PXIe signal analyzer

Step 1. Choose a frequency range (required option; frequency range not upgradeable)
M9290A-F03 Frequency range, 10 Hz to 3.0 GHz
M9290A-F07 Frequency range, 10 Hz to 7.5 GHz
M9290A-F13 Frequency range, 10 Hz to 13.6 GHz
M9290A-F26 Frequency range, 10 Hz to 26.5 GHz
Step 2. Add a preamplifier
Enhances sensitivity to detect low-level signals
M9290A-P03 Preamplifier, 100 kHz to 3 GHz
M9290A-P07 Preamplifier, 100 kHz to 7.5 GHz
M9290A-P13 Preamplifier, 100 kHz to 13.6 GHz
M9290A-P26 Preamplifier, 100 kHz to 26.5 GHz
Step 3. Add precision amplitude accuracy
M9290A-PAA Precision amplitude accuracy Improves amplitude accuracy to <