HP StorageWorks DAT - Troubleshooting for HP StorageWorks DAT8, DAT24, DAT40, and DAT72
Introduction
This document provides troubleshooting steps for some of the most common issues along with links for additional information if needed. Also, a list of other useful links is listed below.
Troubleshooting issue symptoms
Software/application issue LEDs issue Back-up problem Restore problem Stuck tape Drive hung (communication failure) Media problem Performance issue Capacity Loss Load/unload problem Installation/configuration issue Read/write problem Cleaning issue Broken/wrong/missing part
Useful links
HP Library and Tape Tools (www.hp.com/support/tapetools) Performance help (www.hp.com/support/pat) Compatibility help (www.hp.com/go/connect) HP DDS Manuals Warranty information HP Support contact information
Field Code Changed
Software/application issue
Try in the following order: 1. Run Library and Tape Tools Device Analysis test. 2. Check driver is correct and installed. 3. If Windows NT4 - check driver location in the operating system. 4. If Windows NT4 - check SCSI connectivity. 5. If Windows NT4 - check tape device detected by operating system. 6. If Windows NT4 - check if native driver is loaded. 7. If Windows 2000 - check driver location in the operating system. 8. If Windows 2000 - check if there is a plug and play issue. 9. If Windows 2000 - check for driver issues. 10. If Windows 2000 - check removable storage manager. 11. Check system event logs.
12. Decode driver errors. 13. Check application event logs. 14. Check if you have a Netware operating system issue. 15. Check if you have a Tapeware software issue. 16. Check if you have a Colorado Backup issue. 17. Check if you have an Arcserve issue. 18. HP Support contact details.
Software/application troubleshooting details
Run Device Analysis test in Library and Tape Tools Action recommended Run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Check driver is correct and installed Action recommended Check driver is correct and installed. Back to Start of Section Back to Top If NT4 - check driver location in the operating system Action recommended Check operating system drivers in the winnt/system32/drivers directory. Additional information Click here for information on tape drive detection and other Additional information Click here for information on drivers and operating systems. Additional information
Click here for information on HP Library and Tape Tools.
Action recommended
Additional information considerations in Windows NT4 and 2000 operating systems.
Compare driver properties like version and file size with the correct downloaded version from the hp.com Web site. Back to Start of Section Back to Top If NT4 - check SCSI connectivity Action recommended Check Control Panel, then SCSI Adapters. Select the correct SCSI adapter and check that the tape device can be seen. Back to Start of Section Back to Top
Click here for information on drivers and operating systems.
Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems.
If NT4 - check tape device detected by operating system Action recommended Check the tape devices icon in the Control Panel, to display the tape drive model or type. (Select Detect to rescan the bus for attached tape devices). Back to Start of Section Back to Top If NT4 - check if native driver is loaded Action recommended Check the Drivers tab to see if a native driver is listed. If a driver is loaded here then be aware that this will not suffice for ISV backup software such as ARCserve and Backup Exec. Check the properties of the driver to confirm. Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems.
Click here for information on tape Check Control Panel, Devices to check drive detection and other if a device driver is loaded. considerations in Windows NT4 and
Action recommended
Additional information 2000 operating systems.
NOTE: Third party ISV backup software loads its own device drivers and does not appear in the Drivers icon (check Control Panel under Tape Devices and select Drivers.) NOTE: If both the native and ISV driver are loaded then you may get driver timeout errors as both will be trying to access the tape drive simultaneously. Remove native drivers and run the hardware configuration wizard where applicable on the ISV software in order to install and use the correct driver. If Microsoft service pack installed you will need to reload the correct drivers as Microsoft service packs can overwrite HP drivers. Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems.
Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Click here to visit www.hp.com/support/dat.
For Proliant Servers re-run Softpaq on the Server obtainable from the hp.com Web site.
Click here for information on tape Check system event logs for indication of drive detection and other driver errors/timeouts, etc. considerations in Windows NT4 and 2000 operating systems. Back to Start of Section Back to Top If Windows 2000 - check driver location in the operating system Action recommended Operating system drivers can be found in the winnt/system32/drivers directory. Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems.
Action recommended Compare driver properties like version and file size with the correct downloaded version from the hp.com Web site. Back to Start of Section Back to Top
Additional information Click here to visit www.hp.com/support/dat.
If Windows 20000 - check if there is a plug and play issue Action recommended Windows 2000 is plug and play so be aware of its related issues. Check if the drive is detected and check the driver properties in Device Manager, Computer Management, Administrative Tools, then select Tape Devices. If a native driver is loaded then under driver details it will state either Microsoft or some other version of a HP driver, which will allow native backup applet support. Back to Start of Section Back to Top If Windows 2000 - check for driver issues Action recommended If you are using Windows 2000, check for driver issues. Back to Start of Section Back to Top If Windows 2000 - check removable storage manager (RSM) Action recommended Additional information Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems.
Click here for information on tape drive detection and other Removable storage manager (which can be considerations in Windows NT4 found in Services) comes enabled in windows and 2000 operating systems. by default. It should however be set to Disabled unless you are using native backup Click here for information on in Windows 2000. resolving issues caused by RSM (Removable Storage Manager).
Action recommended RSM can cause problems in backup including compression issues. If an issue with RSM is suspected then a reboot will be necessary after setting it to Disable.
Additional information Click here for information on resolving issues caused by RSM (Removable Storage Manager). Click here for information on resolving issues caused by RSM (Removable Storage Manager).
RSM can cause other issues related to backup Click here for information on devices so be aware that it resides in Services resolving issues caused by RSM and will need to be disabled. (Removable Storage Manager). Back to Start of Section Back to Top Check system event logs Action recommended Check the system event logs. Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems.
Back to Start of Section Back to Top Decode driver errors Action recommended Error messages generated by the adpu160m.sys driver can be viewed by opening the Windows NT Event Viewer error logs. Back to Start of Section Back to Top Check application event logs Action recommended Check the Application Event Log and expand it further by double-clicking on the event. If, for example, your license is not correct for your backup application then the backup application will not work. Back to Start of Section Back to Top Check if you have a Netware Operating System issue Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems. Additional information Click here for information on tape drive detection and other considerations in Windows NT4 and 2000 operating systems.
Action recommended Check if you have a Netware Operating System issue Back to Start of Section Back to Top Check if you have a Tapeware Software issue Action recommended Check compatibility with Tapeware. Check for Windows 2000 error 1067Unable to open system mutex. Check for Windows 95/98/NT Unable to access restore/backup or Error 74 - Object already locked on a restore in TapeWare. Check for Windows NT Invalid Windows Application error. Check if scheduled backup did not run. Check for Windows 2002/Tapeware lite System MuTest error . Check for Error 1506 when starting backup. If Windows 2000, check for problems with OBDR. Check if clean option is greyed out. Check for other common issues with Tapeware. Back to Start of Section Back to Top Check if you have a Colorado Backup issue Action recommended Check compatibility with Colorado Backup. Back to Start of Section Back to Top
Additional information
Additional information Click here to visit www.hp.com/go/connect.
Click here for information on TapeWare scheduled backup not running. Click here for information on Installing HP TapeWare Lite in Windows 2000 causing a System MuTest error. Click here for information on TapeWare and Error 1506. Click here for information on problems with TapeWare one button disaster recovery in Windows. Click here for information on the Clean Option being greyed out in TapeWare. Click here for information on common issues with TapeWare 6.0(XE) backup software.
Additional information Click here to visit www.hp.com/go/connect.
Check if you have an Arcserve issue Action recommended Check compatibility with Arcserve. Check if after replacing a drive, ARCserve reports that the drive is offline. Back to Start of Section Back to Top HP Support contact details Action recommended Contact HP Support. Additional information Click here for information on calling HP and other ways to contact HP for technical support. Additional information Click here to visit www.hp.com/go/connect. Click here for information on after replacing the drive, ARCserver reports that the drive is offline.
Back to Start of Section Back to Top
LEDs issue
Try in the following order: 1. 2. 3. 4. 5. 6. 7. Check LEDs to determine the status of your drive. Check if all LEDs are off. Check if green Tape LED is flashing slowly. Check if green Tape LED is flashing rapidly. Check if amber Clean LED is flashing. Check if amber Clean LED is triggered regularly despite cleaning. If DAT8/24/40, check if the cleaning tape is ejected quickly (less than 20 seconds) after loading and the green Tape LED is FLASHING. 8. If DAT72, check if the cleaning tape is held by the drive for more than 2 minutes after loading and the green Tape LED is FLASHING. 9. Check if the amber Clean LED is on constantly. 10. Check if the drive is in OBDR mode (Tape Error and Clean LEDs flashing slowly). 11. Run Device Analysis Test in Library and Tape Tools. 12. Upgrade to latest firmware. 13. HP Support contact details.
LEDs troubleshooting details
Check LEDs to determine the status of your drive Action recommended Check LEDs and confirm drive status by checking the front panel LEDs document. Additional information Click here for information on the HP DAT front panel LEDs.
Back to Start of Section Back to Top Check if all LEDs are off Action recommended Check the power cable is plugged in and power is switched on. Check the drive power switch is turned on. If a tape is not loaded, load a data cartridge. The green Tape LED should flash slowly while the tape loads, then stay on to indicate that a tape is loaded. If the LEDs are still off, power cycle the drive or press the Emergency Reset button. If you are still concerned about the status of your drive run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Check if green Tape LED is flashing slowly Action recommended Reason: The tape is either loading or unloading. This is a transient state. Wait for the tape to finish loading or unloading, or for the drive to report an error. Additional information Click here for information on the HP DAT front panel LEDs. Click here for information on HP Library and Tape Tools. Click here for information on the HP DAT front panel LEDs. Click here for information on the HP DAT front panel LEDs. Additional information
Action recommended NOTE: Unloading a tape can take a few minutes due to the rewind required. Back to Start of Section Back to Top Check if green Tape LED is flashing rapidly Action recommended REASON: The drive mechanism is operating (for instance, writing, reading, spacing). Back to Start of Section Back to Top Check if amber Clean LED is flashing Action recommended
Additional information
Additional information Click here for information on the HP DAT front panel LEDs.
Additional information Click here for information on the clean light flashing on DAT drives. Click here for information on the HP DAT front panel LEDs.
Insert a cleaning cartridge into the drive and wait for the clean to take place. The tape is ejected at the end.
Repeat the clean five times in total. Check for expiry of cleaning tape. Introduce a regular clean into your backup strategy. Back to Start of Section Back to Top Check if amber Clean LED is triggered regularly despite cleaning Action recommended Additional information Click here for information on the clean light flashing on DAT drives. Click here for information on the HP DAT front panel Click here for information on ensuring a long life for the HP DAT product.
Clean the drive five times.
Action recommended
Additional information LEDs.
Check for expiry of cleaning tape. Click here for information on ensuring a long life for the HP DAT product. Click here for information DDS media care. Click here for information DDS media care.
Check frequency of cleaning in backup strategy.
Check environmental conditions of drive and media storage Replace data tape with new tape, it may be worn or at end of life. If problems persist, run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Ensure the latest firmware is loaded. NOTE:
Click here for Due to issues in development Library and Tape information on HP Tools cannot be reliably used to diagnose Library and Tape potential issues with the DAT 40 Hotplug drive Tools. (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected Back to Start of Section Back to Top If DAT8/24/40, check if the cleaning tape is ejected quickly after loading and the green Tape LED is FLASHING Action recommended Additional information Click here for information DDS media care. Click here for
Check that the cleaning cartridge has been used less that 50 times.
Action recommended
Additional information information on the HP DAT front panel LEDs. Click here for information on ensuring a long life for the HP DAT product.
Try a new cleaning cartridge.
Run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Ensure the latest firmware is loaded. NOTE: Click here for Due to issues in development Library and Tape information on HP Tools cannot be reliably used to diagnose Library and Tape potential issues with the DAT 40 Hotplug drive Tools. (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected Back to Start of Section Back to Top If DAT72, check if the cleaning tape is held by the drive for more than two minutes after loading and the green Tape LED is FLASHING Action recommended Eject the cleaning tape using the Eject button (later firmware will retain the cleaning tape, including premerger Compaq drives). Check that the cleaning cartridge has been used less than 50 times. Additional information Click here for information on the HP DAT front panel LEDs. Click here for information DDS media care. Click here for information on ensuring a long life for the HP DAT
Try a new cleaning cartridge.
Action recommended
Additional information product.
Run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Ensure the latest firmware is loaded. NOTE: Click here for Due to issues in development Library and Tape information on HP Tools cannot be reliably used to diagnose Library and Tape potential issues with the DAT 40 Hotplug drive Tools. (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Check if the amber Clean LED is on constantly Action recommended Additional information Click here for information on the HP DAT front panel LEDs. Click here for information on ensuring a long life for the HP DAT product.
REASON: The drive has experienced a hard failure.
Power cycle the drive to see if it recovers normally.
Run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Ensure the latest firmware is loaded. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose Click here for information on HP Library and Tape Tools.
Action recommended potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top
Additional information
Check if the drive is in OBDR mode (Tape Error and Clean LEDs flashing slowly) Action recommended Check if the drive is in OBDR mode (Tape Error and Clean LEDs flashing slowly). If OBDR mode is not required then power cycle the drive to stop the OBDR function. If the drive does not recovery properly, run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test result. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Run Device Analysis Test in L&TT Action recommended Additional information Click here for information on HP Library and Tape Tools. Additional information Click here for information on the HP DAT front panel LEDs.
Action recommended Run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Ensure the latest firmware is loaded. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Upgrade to latest firmware Action recommended Upgrade to latest firmware. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top HP Support contact details
Additional information
Click here for information on HP Library and Tape Tools.
Additional information
Click here for information on HP Library and Tape Tools.
Action recommended Contact HP Support.
Additional information Click here for information on calling HP and other ways to contact HP for technical support.
Back to Start of Section Back to Top
Back-up issue
Try in the following order: 1. Run Device Analysis Test in Library and Tape Tools. 2. Run Read/Write Test in Library and Tape Tools. 3. Run Media Validation Test in Library and Tape Tools. 4. Upgrade to latest firmware. 5. Check back-up logs. 6. Check you are using a supported configuration and correct media. 7. Check if verify has failed. 8. Check if the scheduled back-up has failed. 9. Check for media damage. 10. Check that the drive has been cleaned. 11. Check for back-up software issues. 12. Check you can format a tape. 13. Check IRQ assigning. 14. HP Support contact details.
Back-up troubleshooting details
Run Device Analysis Test in Library and Tape Tools Action recommended Run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Ensure the latest firmware is loaded. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Click here for information on HP Library and Tape Tools. Additional information
Action recommended Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Run Read/Write Test in Library and Tape Tools Action recommended Run the Read / Write test in HP Library and Tape Tools (L&TT). NOTE:
Additional information
Additional information
Due to issues in development Library and Tape Tools cannot be reliably used to Click here for information diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is on HP Library and Tape Tools. currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Click here for information on performance troubleshooting and using performance assessment tools.
Check drive performance using PAT tools.
Back to Start of Section Back to Top Run Media Validation Test in Library and Tape Tools Action recommended Run the Media Validation Test in HP Library and Tape Tools (L&TT). NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated Click here for information on HP Library and Tape Tools. Additional information
Action recommended and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Upgrade to latest firmware Action recommended Upgrade to latest firmware using HP Library and Tape Tools (L&TT). NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Check back-up logs Action recommended Check back-up logs. Back to Start of Section Back to Top
Additional information
Additional information
Click here for information on HP Library and Tape Tools.
Additional information
Check you are using a supported configuration and correct media Action recommended Check you are using a supported configuration. Additional information Click here to visit www.hp.com/go/connect.
Action recommended Check you are using correct media. Back to Start of Section Back to Top Check if verify has failed Action recommended Check if verify has failed. Check if you have open file module installed on your backup software. Back to Start of Section Back to Top Check if the scheduled back-up has failed Action recommended
Additional information Click here for a DDS media compatibility matrix.
Additional information Check with your ISV vendor for more information. Check with your ISV vendor for more information.
Additional information
If your scheduled backup has failed, check that the files to be backed up are actually present on the target directory and available to be backed-up. Back to Start of Section Back to Top Check for media Action recommended Additional information Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen. Inspect your media and discard if faulty or damaged. Check for the following: o o o o Incorrect label placement Damage Usage in incorrect environment Snapped/damaged tape Click here for information on visually inspecting HP DDS media. Click here for information on DDS media label placement. Click here for information DDS media care. Click here for information on ensuring a long life for the HP DAT product.
Back to Start of Section Back to Top Check that the drive has been cleaned Action recommended Insert a cleaning cartridge into the drive and wait for the clean to take place. The tape is ejected at the end. Repeat the clean five times in total. Check for expiry of cleaning tape. Introduce a regular clean into your backup strategy. Back to Start of Section Back to Top Check for back-up software issues Action recommended Check whether the backup scheduler is going off unexpectedly. Check for other common issues with Tapeware 6.0(XE). Check that virus scanning software is not scheduled to run at the same time as the back-up. Check your network resources (bandwidth, run HP PAT test). Back to Start of Section Back to Top Check you can format a tape Action recommended Try and format a tape. Back to Start of Section Back to Top Check IRQ assigning Additional information Click here for information on performance troubleshooting and using performance assessment tools. Additional information Click here for information on the tape backup scheduler going off unexpectedly. Click here for information on common issues with TapeWare 6.0(XE) backup software. Click here for information on ensuring a long life for the HP DAT product. Additional information Click here for information on clean light flashing on DAT Drives.
Action recommended Check for symptoms like: o o o ID9 and ID11 errors in the system event logs of servers. Driver errors and timeouts listed in the system event log. Possible IO errors in ISV logs.
Additional information
This happens when two devices which are unlike are assigned the same IRQ. Both PM HP and PM Compaq Servers can end up with incorrect IRQ routing due to automatic IRQ routing in their BIOS. This can cause issues with both drivers and performance. To correct this problem you will need to manually assign the IRQ' s via the system BIOS taking into account any shared slots with onboard-embedded devices, etc. Always assign IRQ' s at a hardware level in the system BIOS and not in the Operating System. Back to Start of Section Back to Top HP Support contact details Action recommended Contact HP Support. Additional information Click here for information on calling HP and other ways to contact HP for technical support.
Back to Start of Section Back to Top
Restore issues
Try in the following order: 1. Check if you have data (the required files) on your tape. 2. Run Device Analysis Test in Library and Tape Tools. 3. Run Media Validation Test in Library and Tape Tools. 4. Check if verify has failed. 5. Check the target device is accessible. 6. Check for media damage. 7. Check the drive has been cleaned. 8. Check you are using a supported configuration. 9. Upgrade to latest firmware. 10. HP Support contact details.
Restore troubleshooting details
Check if you have data (the required files) on your tape Action recommended Check if you have data on the loaded tape. Check that the required files are on the loaded tape. Back to Start of Section Back to Top Run Device Analysis Test in Library and Tape Tools Action recommended Run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Run Media Validation Test in Library and Tape Tools Action recommended Run the Media Validation Test in HP Library and Tape Tools (L&TT). NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A Click here for information on HP Library and Tape Tools. Additional information Click here for information on HP Library and Tape Tools. Additional information Additional information
Action recommended only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Check if verify has failed Action recommended Check if verify has failed. Check if you have open file module installed on your backup software. Back to Start of Section Back to Top Check the target device is accessible Action recommended Check that the target device is available. Back to Start of Section Back to Top Check for media damage Action recommended
Additional information
Additional information Check with your ISV vendor for more information. Check with your ISV vendor for more information.
Additional information
Additional information Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen. Click here for information on visually inspecting HP DDS media. Click here for information on DDS media label placement. Click here for information DDS
Inspect your media and discard if faulty or damaged. Check for the following: o o o o Incorrect label placement Damage Usage in incorrect environment Snapped/damaged tape
Action recommended
Additional information media care. Click here for information on ensuring a long life for the HP DAT product.
Back to Start of Section Back to Top Check that the drive has been cleaned Action recommended Insert a cleaning cartridge into the drive and wait for the clean to take place. The tape is ejected at the end. Repeat the clean five times in total. Check for expiry of cleaning tape. Introduce a regular clean into your backup strategy. Back to Start of Section Back to Top Check you are using a supported configuration Action recommended Check you are using a supported configuration. Check you are using correct media. Back to Start of Section Back to Top Upgrade to latest firmware Action recommended Upgrade to latest firmware. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive Additional information Click here for information on HP Library and Tape Tools. Click here for information on being unable to upgrade Additional information Click here to visit www.hp.com/go/connect. Click here for a DDS media compatibility matrix. Click here for information on ensuring a long life for the HP DAT product. Additional information Click here for information on clean light flashing on DAT Drives.
Action recommended (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top HP Support contact details Action recommended Contact HP Support.
Additional information firmware on a DDS4/DAT40 autoloader.
Additional information Click here for information on calling HP and other ways to contact HP for technical support.
Back to Start of Section Back to Top
Stuck tape issue
Try in the following order: 1. 2. 3. 4. 5. 6. 7. 8. 9. Manually press the Eject button. Perform a Forced Eject. Power cycle the drive. Check for conflicts in backup software services. Check SCSI/HBA/Driver configuration of the drive. Check the software has not sent a prevent media removal command. Run Library and Tape Tools device analysis test. Upgrade to the latest firmware. HP Support contact details.
Stuck tape troubleshooting details
Manually press the Eject button Action recommended Press the Eject button. Allow one minute for the tape to eject. Additional information Click here for information on the media being jammed and unable to eject. Click here for information on the media being jammed and
Action recommended
Additional information unable to eject. Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen.
Inspect your Media and SCSI cables, and discard if faulty or damaged. Check for the following: o o o o Incorrect label placement. Damage. Usage in incorrect environment. Snapped/damaged tape.
Click here for information on visually inspecting HP DDS media. Click here for information on DDS media label placement. Click here for information DDS media care. Click here for information on ensuring a long life for the HP DAT product.
Back to Start of Section Back to Top Perform a Forced Eject Action recommended Press (and hold in) the Eject button for 10 seconds Allow one minute for the tape to eject. Additional information Click here for information on the Eject button operation for the Ultrium drive. Click here for information on the media being jammed and unable to eject. Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen. Click here for information on visually inspecting HP DDS media. Click here for information on DDS media label placement. Click here for information DDS media care.
Inspect your Media and SCSI cables, and discard if faulty or damaged. Check for the following: o o o o Incorrect label placement. Damage. Usage in incorrect environment. Snapped/damaged tape.
Action recommended
Additional information Click here for information on ensuring a long life for the HP DAT product.
Back to Start of Section Back to Top Power cycle the drive Action recommended Power cycle the drive. Power cycle the server to re-scan the SCSI bus. Allow up to five minutes for the drive to become ready again. Back to Start of Section Back to Top Check for conflicts in backup software services Action recommended RSM (removable storage manager) should be disabled for ISV software. RSM (removable storage manager) should be enabled for native backup applet. Removable storage manager can be found in Computer Management/Services in Windows 2000 and must only be used if the native backup applet is being used. To check if in use please check Services and see if it is started. Back to Start of Section Back to Top Check SCSI/HBA/Driver configuration of the drive Action recommended Additional information Click here for information on recommended SCSI HBA adapters for tape products. Click here for information on SCSI cables and termination. Click here for information on SCSI Click here for information on resolving issues caused by RSM (Removable Storage Manager). Additional information Additional information
Ensure the power and SCSI cables are correct, properly connected and undamaged.
Ensure that the SCSI bus is correctly
Action recommended terminated. Ensure that the tape drive SCSI ID is correct and unique on the bus. Ensure that the application being used supports the tape drive.
Additional information cables and termination. Click here for information on SCSI cables and termination. Click here to visit www.hp.com/go/connect. Click here for information on drivers and operating systems.
Ensure that the correct driver is loaded. Click here to visit www.hp.com/go/connect. Ensure that there are no HBA problems (check the system event log for HBA errors). Click here for information on recommended SCSI HBA adapters for tape products. Click here for information on recommended SCSI HBA adapters for tape products. Click here to visit www.hp.com/go/connect. Ensure there are no tape driver problems Click here for information on HP (check the system event log for tape Library and Tape Tools. driver errors). If easy, isolate the drive so that it is the only one on the bus. Click here for information on SCSI cables and termination. Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen. Inspect your Media and SCSI cables, and discard if faulty or damaged. Check for the following: o o o o Incorrect label placement Damage Usage in incorrect environment Snapped/damaged tape Click here for information on visually inspecting HP DDS media. Click here for information on DDS media label placement. Click here for information DDS media care. Click here for information on ensuring a long life for the HP DAT product. Back to Start of Section Back to Top Check the software has not sent a prevent media removal command
Ensure that the host, HBA, application, driver, and drive are all compatible.
Action recommended Check that the software has not sent the tape drive a prevent media removal command to prevent an accidental eject. Check with the backup application software vendor on how to change this option and send the drive an enable media removal command to restore control to the eject switch. Alternatively, a SCSI reset will have the same effect. Back to Start of Section Back to Top Run Library and Tape Tools device analysis test Action recommended Run the Device Analysis Test in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Upgrade to the latest firmware Action recommended Run HP Library and Tape Tools (L&TT) and upgrade to latest firmware. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A
Additional information Click here for information on the media being jammed and unable to eject.
Additional information
Click here for information on HP Library and Tape Tools.
Additional information
Click here for information on HP Library and Tape Tools.
Action recommended only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top HP Support contact details Action recommended Contact HP Support. Additional information
Additional information
Click here for information on calling HP and other ways to contact HP for technical support.
Back to Start of Section Back to Top
Hung drive issue
Try in the following order: 1. 2. 3. 4. 5. 6. 7. 8. Run Library and Tape Tools to check connectivity. Power cycle the drive. Check SCSI/HBA/Driver configuration of the drive. Check LEDs. Swap drive to a known good system and test using Library and Tape Tools. Inspect power and SCSI cables, discard if faulty or damaged. Re-run Library and Tape Tools to check connectivity and upgrade to latest firmware. HP Support contact details.
Hung drive troubleshooting details
Run Library and Tape Tools to check connectivity Action recommended Run HP Library and Tape Tools (L&TT) to check connectivity to the drive. NOTE: Due to issues in development Library and Tape Additional information Click here for information on HP Library and Tape Tools.
Action recommended Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. If drive can be seen, upgrade to latest firmware. Back to Start of Section Back to Top Power cycle the drive Action recommended Power cycle the drive. Power cycle the server to re-scan the SCSI bus. Allow up to five minutes for the drive to become ready again. Run HP Library and Tape Tools (L&TT) to check connectivity to the drive. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. If drive can be seen, upgrade to latest firmware. Back to Start of Section Back to Top Check SCSI/HBA/Driver configuration of the drive
Additional information
Additional information
Click here for information on HP Library and Tape Tools.
Action recommended
Additional information Click here for information on recommended SCSI HBA adapters for tape products. Click here for information on SCSI cables and termination. Click here for information on SCSI cables and termination. Click here for information on SCSI cables and termination. Click here to visit www.hp.com/go/connect. Click here for information on drivers and operating systems.
Ensure the power and SCSI cables are correct, properly connected and undamaged.
Ensure that the SCSI bus is correctly terminated. Ensure that the tape drive SCSI ID is correct and unique on the bus. Ensure that the application being used supports the tape drive.
Ensure that the correct driver is loaded. Click here to visit www.hp.com/go/connect. Ensure that there are no HBA problems (check the system event log for HBA errors). Click here for information on recommended SCSI HBA adapters for tape products. Click here for information on recommended SCSI HBA adapters for tape products. Click here to visit www.hp.com/go/connect. Ensure there are no tape driver problems Click here for information on HP (check the system event log for tape Library and Tape Tools. driver errors). If easy, isolate the drive so that it is the only one on the bus. Click here for information on SCSI cables and termination. Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen. Click here for information on visually inspecting HP DDS media. Click here for information on DDS media label placement. Click here for information DDS media care. Click here for information on
Ensure that the host, HBA, application, driver, and drive are all compatible.
Inspect your Media and SCSI cables, and discard if faulty or damaged. Check for the following: o o o o Incorrect label placement Damage Usage in incorrect environment Snapped/damaged tape
Action recommended
Additional information ensuring a long life for the HP DAT product.
Back to Start of Section Back to Top Check LEDs Action recommended Check LEDs Back to Start of Section Back to Top Swap drive to a known good system and test using Library and Tape Tools Action recommended Swap the drive to a known good/working system, then test communications to the drive using Library and Tape Tools. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Inspect power and SCSI cables, and discard if faulty or damaged Action recommended Inspect media, power and SCSI cables, and discard if faulty or damaged. Additional information Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen. Click here for information on visually Click here for information on HP Library and Tape Tools. Additional information Additional information Click here for information on the HP DAT front panel LEDs.
Action recommended
Additional information inspecting HP DDS media. Click here for information on DDS media label placement. Click here for information DDS media care. Click here for information on ensuring a long life for the HP DAT product.
Back to Start of Section Back to Top Re-run Library and Tape Tools to check connectivity and upgrade to latest firmware Action recommended Re-run HP Library and Tape Tools (L&TT) to re-check connectivity to the drive. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. If drive can be seen, upgrade to latest firmware. Back to Start of Section Back to Top HP Support contact details Action recommended Contact HP Support. Additional information Click here for information on calling HP and other ways to contact HP for technical support. Click here for information on HP Library and Tape Tools. Additional information
Back to Start of Section Back to Top
Media issue
Try in the following order: 1. 2. 3. 4. 5. 6. 7. 8. 9. Check correct media is being used. Test media using Media Validation Test in Library and Tape Tools. Check for media damage. Check if the drive is cleaned regularly. Check if Clean LED is flashing. Check if you are using more than two tapes a day. Run Library and Tape Tools and upgrade to latest firmware. Media care and cleaning information. HP Support contact details.
Media troubleshooting details
Check correct media is being used Action recommended Check correct media is being used. Back to Start of Section Back to Top Test media using Media Validation Test in Library and Tape Tools Action recommended Test media in L&TT using Media Validation Test from Tests drop down list. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Check for media damage Click here for information on HP Library and Tape Tools. Additional information Additional information Click here for a DDS media compatibility matrix.
Action recommended
Additional information Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen. Click here for information on visually inspecting HP DDS media.
Inspect your media and discard if faulty or damaged. Check for the following: o o o o Incorrect label placement Damage Usage in incorrect environment Snapped/damaged tape
Click here for information on DDS media label placement. Click here for information DDS media care. Click here for information on ensuring a long life for the HP DAT product. Click here for information on the Defective Media Exchange Process for Travan, DDS, MO, CDR/RW Media (Warranty Process).
Back to Start of Section Back to Top Check if the drive is cleaned regularly Action recommended Insert a cleaning cartridge into the drive and wait for the clean to take place. The tape is ejected at the end. Repeat the clean five times in total. Introduce a regular clean into your backup strategy. Back to Start of Section Back to Top Check if Clean LED is flashing Action recommended Additional information Click here for information on DAT autoloaders front panel. Click here for Click here for information on ensuring a long life for the HP DAT product. Additional information
Insert a cleaning cartridge into the drive and wait for the clean to take place.
Action recommended
Additional information information on Autoloader LCD Messages.
Repeat the clean five times in total. Check for expiry of cleaning tape. Check the environmental conditions of the drive and media storage. Replace the data tape with a new tape, it may be worn or at end of life. Click here for information on ensuring a long life for the HP DAT product. Click here for information DDS media care. Click here for information on ensuring a long life for the HP DAT product.
Introduce a regular clean into your backup strategy. Run Device Analysis Test from Test drop down menu in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Ensure your drive is running with the latest firmware. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Check if you are using more than two tapes a day Action recommended
Click here for information on HP Library and Tape Tools. Click here for information on being unable to upgrade firmware on a DDS4/DAT40 autoloader.
Additional information
Check if you are using more than two tapes a day. Your drive
Action recommended cannot be support by HP if your duty cycle is >12% (more than two tapes per day). Back to Start of Section Back to Top
Additional information
Run Library and Tape Tools and upgrade to latest firmware Action recommended Run Device Analysis Test from Test drop down menu in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Ensure your drive is running with the latest firmware. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top Media care and cleaning information Action recommended Additional information Click here for a DDS media compatibility matrix. Click here for information DDS media care. More information on DDS media. Click here for information on ensuring a long life for the HP DAT product. Click here for information on how to detect a damaged DDS cartridge and what symptoms would be seen. Click here for information on visually inspecting HP DDS Click here for information on HP Library and Tape Tools. Additional information
Action recommended media.
Additional information
Click here for information on DDS media label placement. Click here for information on the Defective Media Exchange process for Travan, DDS, MO, CDR/RW media (Warranty Process). Back to Start of Section Back to Top HP Support contact details Action recommended Contact HP Support. Additional information Click here for information on calling HP and other ways to contact HP for technical support.
Back to Start of Section Back to Top
Performance issue
Try in the following order: 1. 2. 3. 4. 5. Check performance using HPTapePerf. Performance troubleshooting steps. Check drive using Library and Tape Tools. Additional help on performance and using HP Performance Assessment Tools. HP Support contact details.
Performance troubleshooting details
Check performance using HPTapePerf Action recommended Additional information
Click here for information on performance Check performance using troubleshooting and using performance assessment HPTapePerf. tools. Back to Start of Section Back to Top Performance troubleshooting steps Action recommended Additional information
Action recommended Check the ISV software configuration is optimized. Check if the drive is backing up over a network (can cause poor performance).
Additional information Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed). Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed). Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed). Click here for information on data compression.
Check the compression ratio achieved on the drive.
Check the performance of the server using HP PAT test.
Click here for information on performance troubleshooting and using performance assessment tools.
Click here for information on HP Surestore Check for other peripherals on the DAT, DLT, DLT1 and DLTVS80 Performance same bus. (Capacity and Speed). Check the SCSI adaptor set up. Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed). Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed). Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed). Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed). Check the media usage, old media can cause degraded performance. Click here for information DDS media care. Click here for information on ensuring a long life for the HP DAT product. Back to Start of Section Back to Top Check drive using Library and Tape Tools Action recommended Run Device Analysis Test from Test drop down menu in HP Library and Tape Tools (L&TT). Follow any troubleshooting Additional information Click here for information on HP
Check for the use of push agents. Check for the use of virus detection software.
Action recommended given with the test results. Run the Read/Write test in L&TT. Check ERT performance in the support ticket. Ensure your drive is running with the latest firmware. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top
Additional information Library and Tape Tools.
Additional help on performance and using HP Performance Assessment Tools Action recommended Additional information Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed). Information on performance troubleshooting and using performance assessment tools. Click here for information on data compression. Click here for information on performance troubleshooting and using performance assessment tools. Back to Start of Section Back to Top HP Support contact details Action recommended Contact HP Support. Additional information Click here for information on calling HP and other ways to contact HP for technical support.
Back to Start of Section
Back to Top
Capacity loss issue
Try in the following order: 1. 2. 3. 4. 5. Check compression. Check media type. Check file system for zip files. Check performance of drive using Library and Tape Tools. HP Support contact details.
Capacity loss troubleshooting details
Check compression Action recommended Additional information Click here for information on HP Surestore DAT, DLT, DLT1 and DLTVS80 Performance (Capacity and Speed).
Check the compression ratio achieved on the drive (always enable hardware Click here for information on data compression and disable software compression. compression).
Click here for information on performance troubleshooting and using performance assessment tools. Back to Start of Section Back to Top Check media type Action recommended Check correct media type is being used. Back to Start of Section Back to Top Check file system for zip files Action recommended Check file system for zip files (you can't compress zip files, jpeg files, audio files, etc). Back to Start of Section Back to Top Additional information Additional information Click here for a DDS media compatibility matrix.
Check performance of drive using Library and Tape Tools Action recommended Run Device Analysis Test from Test drop down menu in HP Library and Tape Tools (L&TT). Follow any troubleshooting given with the test results. Run the Read/Write test in L&TT. Check ERT performance in the support ticket. Ensure your drive is running with the latest firmware. NOTE: Due to issues in development Library and Tape Tools cannot be reliably used to diagnose potential issues with the DAT 40 Hotplug drive (Q1546A only). This problem is currently being investigated and will be corrected in the next revision of Library and Tape tools. This note will be updated once the problem has been corrected but until then do not use Library and Tape Tools to diagnose issues with this product. This problem only relates to the Q1546A product, no other DAT 40 variants are affected. Back to Start of Section Back to Top HP Support contact details Action recommended Contact HP Support. Additional information Click here for information on calling HP and other ways to contact HP for technical support. Click here for information on HP Library and Tape Tools. Additional information
Back to Start of Section Back to Top
Load/unload issue
Try in the following order: 1. 2. 3. 4. 5. 6. 7. Check that media can be loaded into the drive. Check if the media is ejected after insertion . Check if tape is stuck in the drive (not visible behind the door). Check if the media is stuck in the drive (door partially open) . Check if your drive is repeatedly trying to eject media. Check if your media is ejecting after backup. HP Support contact details.
Load/unload troubleshooting details
Check that media can be loaded into the drive Action recommended Try loading a tape into the tape drive. If you have problems getting the tape to load, try the steps listed below. Check the correct media is being used. Check the cartridge is being loaded in the correct orientatio