Text preview for : Rework instruction for surge failure in Power supply.pdf part of Philips Rework instruction for surge failure in Power supply Philips LCD TV (and TPV schematics) 40PFL5606D77 Rework instruction for surge failure in Power supply.pdf



Back to : Rework instruction for su | Home

Rework instruction No. Date 2012.09. 19 Rev.Date
JY CHOI DS LEE
For BD601 or U101 Model Rev. Rev. 0


1. Preparations for rework 2. Components
1) F101 (FUSE AXIAL 02153.15MXK17P, T3.15A/250V)
1) Solder
2) Solder wire
3) Multi Meter (beep and diode mode needed)
4) IPB
2) D101, D102, D103 (DIODE 1N4007 1A 1000V)
5) Components (described right side)
6) De-solder


3) BD601(DIODE BRIDGE RS405M 4A 600V)




4) U101(LNK362PG, STBY IC)




Nipper Recommendation:
In case of either BD601 or U101 is damaged,
LGIT suggest that all indicated above components should be replaced.
Because when simulating surge test, D101,D102, D103 also could be damaged
Solder and Solder wire


Main component Sub material Tools Safety warning

F101 Solder
D101,D102 Solder wire
D103 Multi Meter
BD601 TV Set

U101 Nipper
De-solder No. Date. Reason
LGIT
Rework instruction No. Date 2011.05. 24 Rev.Date
JY CHOI DS LEE
For BD601 or U101 Model Rev. Rev. 0


3. Preparation for ESD control during rework



1) Wear the ESD gloves and ESD wrist strap 2) Work table should be covered with ESD mat



ESD gloves




ESD wrist strap ESD mat




Main component Sub material Tools Safety warning

F101 Solder
D101,D102 Solder wire
D103 Multi Meter
BD601 TV Set

U101 Nipper
De-solder No. Date. Reason
LGIT
Rework instruction No. Date 2011.05. 24 Rev.Date
JY CHOI DS LEE
For BD601 or U101 Model Rev. Rev. 0


4. Confirm the location




U101(LNK362) U101(LN
K362)

D101, D102, D103 D101, D102, D103
(1N4007) (1N4007)


BD601(RS405M) BD601(RS405M)




F101(T3.15A/250V) F101(T3.15A/250V)

TOP BOTTOM

Main component Sub material Tools Safety warning

F101 Solder
D101,D102 Solder wire
D103 Multi Meter
BD601 TV Set

U101 Nipper
De-solder No. Date. Reason
LGIT
Rework instruction No. Date 2011.05. 24 Rev.Date
JY CHOI DS LEE
For BD601 or U101 Model Rev. Rev. 0


5. Diagnosis and Rework flow



1) F101 (FUSE AXIAL 02153.15MXK17P, T3.15A/250V)

During
mode Result
Test
Sounds
OK
Beep Heard
No sound NG

Test result assessment


confirm failure using multi meter
- Direction is not concern for this If measured range is wrong,
- Mode: beep mode of multimeter Change to new one




Main component Sub material Tools Safety warning

F101 Solder
D101,D102 Solder wire
D103 Multi Meter
BD601 TV Set

U101 Nipper
De-solder No. Date. Reason
LGIT
Rework instruction No. Date 2011.05. 24 Rev.Date
JY CHOI DS LEE
For BD601 or U101 Model Rev. Rev. 0


5. Diagnosis and Rework flow



2) D101, D102, D103 (MMSD4148)

Mode Position Red(+) Black(-) OK range
D101 1 2 0.57~0.59 V
diode D102 1 2 0.57~0.59 V
D103 1 2 0.57~0.59 V
Test result assessment


confirm failure using multi meter
- Direction is important for this 1 2
- Mode: diode mode




If measured range is wrong,
Change to new one


Main component Sub material Tools Safety warning

F101 Solder
D101,D102 Solder wire
D103 Multi Meter
BD601 TV Set

U101 Nipper
De-solder No. Date. Reason
LGIT
Rework instruction No. Date 2011.05. 24 Rev.Date
JY CHOI DS LEE
For BD601 or U101 Model Rev. Rev. 0


5. Diagnosis and Rework flow



3) BD601(DIODE BRIDGE RS405M 4A 600V)

Mode Position Red(+) Black(-) OK range
4 3 0.56~0.58V
4 2 0.56~0.58V
diode BD601
4 1 0.49~0.51V
2 1 0.56~0.58V
Test result assessment

If measured range is wrong,
Change to new one

confirm failure using multi meter
- Direction is important for this
1 2 3 4
- Mode: diode mode




Main component Sub material Tools Safety warning

F101 Solder
D101,D102 Solder wire
D103 Multi Meter
BD601 TV Set

U101 Nipper
De-solder No. Date. Reason
LGIT
Rework instruction No. Date 2011.05. 24 Rev.Date
JY CHOI DS LEE
For BD601 or U101 Model Rev. Rev. 0


5. Diagnosis and Rework flow



4) U101(LNK362PG, STBY IC)

Mode Position Red(+) Black(-) OK range
8 5 0.57~0.59V
diode U101 4 4 0.65~0.68V
4 3 0.53~0.55V

Test result assessment
confirm failure using multi meter
- Direction is important for this
- Mode: diode mode
If measured range is wrong,
1 8 Change to new one

2 7
3
4 5


Main component Sub material Tools Safety warning

F101 Solder
D101,D102 Solder wire
D103 Multi Meter
BD601 TV Set

U101 Nipper
De-solder No. Date. Reason
LGIT
Rework instruction No. Date 2011.05. 24 Rev.Date
JY CHOI DS LEE
For BD601 or U101 Model Rev. Rev. 0


6. Final TV Set test



Conduct TV set on/off test and confirm whether LPB on TV set works normally.




Main component Sub material Tools Safety warning

F101 Solder
D101,D102 Solder wire
D103 Multi Meter
BD601 TV Set

U101 Nipper
De-solder No. Date. Reason
LGIT