Readme.txt file
Date: 08 Dec 2006
Product: TDSDDM2 (Disk Drive Measurements 2).
Version: 3.0.1
This file contains more up-to-date information than will be found
in the TDSDDM2.pdf or TDSDDM2.hlp files. Installation instructions
and model support information in this file supercedes the help and
PDF files.
===============================================================
What is in this Readme File:
1. System Requirements
2. Contents of Distribution
3. New Features
-V1.2.0
-V1.2.1
-V1.2.2
-V1.2.3
-V1.3.0
-V1.3.1
-V1.3.2
-V3.0.0
-V3.0.1
4. Known Problems
5. Installation
6. Contact Information
===============================================================
1. System Requirements
- TekScope Software version required for this release:
Product SW Version
================ ================
DPO70404, DPO70604 2.0.0 or above
DPO70804, DSA70404
DSA70604, DSA70804
DPO7054, DPO7104
DPO7254
TDS7054, TDS7104 2.2.0 or above
TDS7154, TDS7254
TDS7404, CSA7154
CSA7404
TDS7254B, TDS7404B 3.0.0 or above
TDS7154B, TDS7704B
CSA7404B
TDS5034, TDS5054 1.0.9 or above
TDS5104,
TDS5034B, TDS5054B 2.0.0 or above
TDS5104B
TDS6604B, TDS6804B 4.0.1 or above
TDS6124C, TDS6154C 5.0.0 or above
- P6247, P6248, or P7330 Differential Probes are recommended for connecting the
Read Signal input to an oscilloscope channel.
- Sun Microsystem's Java Runtime Environment (JRE) version 1.4.2_04 is
required for this release.
- Disk space requirements:
8.5MB of free disk space to install and operate this application.
- Note that while TDSDDM2 will run on two channel instruments the "Sector" mode
should not be used on those instruments since it requires three channels.
- Refer to the TDSDDM2 manual for more requirements.
- The JRE will be installed when TDSDDM2 is installed. If the JRE is deleted
then re-install TDSDDM2
- This software download offers Five (5) Free Trials for evaluation. Once the
five free trials are exhausted, a software security key may be purchased from
Tektronix to permanently enable the software application on your oscilloscope.
===============================================================
2. This Distribution includes these files:
C:\Program Files\TekApplications\TDSDDM2
ddm2.jar
InstGpibNative.dll
Readme.txt
SRM.xml
starthelp.bat
tdsddm2.bat
TDSDDM2.cnt
TDSDDM2.GID
TDSDDM2.HLP
TDSDDM2.pdf
tdsddm2ctrl.c
version.ini
C:\TekApplications\tdsddm2\waveforms:
asperity.wfm
baselineShift.wfm
ovhisig.wfm
ovlosig.wfm
taapw50.wfm
x9x4x1.wfm
===============================================================
3. New Features
v3.0.1
- Support for the latest DPO Tektronix instruments.
- Fixed out of memory error with 50M RL on DPO7254.
---------------------------------------------------------------
v3.0.0
- Support for DPO7000 and DSA/DPO70000 instruments.
- Update to Sun Microsystem's Java (TM) Runtime Environment (JRE)
version 1.4.2_04 incorporated.
---------------------------------------------------------------
V1.3.2
- Provide TDS6604B and TDS6804B support.
---------------------------------------------------------------
V1.3.1
- Correction to this readme file only. No software change from V1.3.0.
Corrected list of the TekScope Software Product models supported
by TDSDDM2.
---------------------------------------------------------------
V1.3.0
- Update to support XGA display resolution.
---------------------------------------------------------------
V1.2.3
- Update to Sun Microsystem's Java (TM) Runtime Environment (JRE)
version 1.2.2-14 incorporated.
---------------------------------------------------------------
V1.2.2
- Enhanced instGpibNative.dll [v4.1.0.1], for TekVisa
---------------------------------------------------------------
V1.2.1
- Qualified on Windows2000 (TM) Professional Operating System
and backward compatible with Windows98 (TM) and WindowsME
(TM) OS.
- Added Start menu shortcuts for OLH and the PDF
Start > Programs> TekApplications> TDSDDM2> Help (PDF Version)
Start > Programs> TekApplications> TDSDDM2> Help
---------------------------------------------------------------
V1.2.0
- The range of the filters is displayed on the Filter panel.
- For the filters an Update button was added to update the filter ranges
after the sample rate of the instrument has been changed.
- The behavior of the file chooser has been improved.
- A GPIB command was added to set/query the Asperity threshold.
===============================================================
4. Known Problems
V3.0.0
- Unchanged from V1.3.2
---------------------------------------------------------------
V1.3.2
- Unchanged from V1.3.1
---------------------------------------------------------------
V1.3.1
- Unchanged from V1.3.0
---------------------------------------------------------------
V1.3.0
- Unchanged from V1.2.3
---------------------------------------------------------------
V1.2.3
- Unchanged from V1.2.2
---------------------------------------------------------------
V1.2.2
- Unchanged from V1.2.1
- If the application fails to restore the Oscilloscope settings on exit,
then make certain the folder "C:\Windows\temp" exists.
---------------------------------------------------------------
V1.2.1
- Unchanged from V1.2.0
- The "Hide" or "Close" Button/Icon can intermittently remain in foreground
when TekScope application goes to full window and displays the "App"
button. If this occurs, click anywhere in TekScope Application to bring
TekScope application forward.
---------------------------------------------------------------
V1.2.0
- Due to a bug in Sun's JRE v 1.2.2 dragging a dialog box to the 2nd
monitor causes the contents of the window to be displayed on the
wrong monitor.
- The possibility exists that if the same reference memory is selected to
store more than one waveform the application might hang since only one
waveform may be stored in a ref. The work around is to ensure that each
reference memory is used for only one waveform.
===============================================================
5. Installation
Normally, the TDSDDM2 application resides on the hard drive of your
oscilloscope. If the application is not installed on hard disk perform
the following steps to install the application from the Optional
Applications Software on a Windows-Based Oscilloscope Compact disc (CD-ROM.)
1. If the keyboard is not installed, connect it to the oscilloscope rear
panel (the optional-accessory keyboard plugs into the DDM connector).
2. Power on the oscilloscope to start Windows.
3. Install the optional applications software CD in the CD-ROM/DVD Drive
of the oscilloscope.
4. The AutoOpen utility will start the installation program.
5. Select the option 'Install Products'.
6. Select the option 'Disk Drive Measurement'.
7. Select the option 'INSTALL NOW'.
8. Follow the instructions given by the InstallShield Wizard. If Java
Run-time Environment (JRE 1.4.2_04) software is not previously installed
then the InstallShield Wizard will prompt for installing it.
Click "Yes" when prompted for installing JRE 1.4.2 and the InstallShield
will install it.
The oscilloscope must reboot to complete the installation process.
9. You will need to enter the authorized Option Installation Key to enable
the application. The key is specific to the serialized oscilloscope and
options for which it was purchased.
Do not enter this key until all application software that you have
purchased has been installed. To enter the key number, follow these steps:
a. If the oscilloscope powered on in the toolbar mode (default), select
the Menu button (upper right corner of the display) to put the
oscilloscope into menu-bar mode. In menu-bar mode you should see a
PC-style menu across the top of the display.
b. Go to the Utilities menu in the menu bar and select Option
Installation.
c. Follow the on-screen instructions to enter the alphanumeric key
number exactly as it is printed on the rear-panel label.
NOTE:
If the AutoOpen utility fails to start, then Select the My Computer icon.
In the Exploring My Computer window, select the CD-ROM (for example, D:)
drive.
Select the file Launch.exe to start the installation program. Complete
===============================================================
6. Contact Information
- Telephone:
Contact your local Tektronix Representative at 1-800-833-9200
Sales support, select option 1
Service support, select option 2
Technical support, select option 3
-WEB:
http://www.tektronix.com/Measurement/scopes/index.html
Click on "Software & Drivers" under the "Resources For You" set of
links on the left.
---End of File---