Text preview for : Digitrex GKX-9000 PSU Improvements.txt part of Digitrex GKX-9000 Improvements for Digitrex GKX-9000 PSU.
Back to : Digitrex GKX-9000 PSU Imp | Home
Change C33 to a 1kV ceramic type.
This protects components on the +3.3V line should C33 (a 50V ceramic) becomes short-circuited through voltage spikes over time.
Add a 1N4751 zener diode in parallel with C2 (Cathode on +ve of C2, Anode on -ve of C2)
This offers additional protection to IC1.