1/12


ADJUSTMENT
Common Section
Measurement Adjustment
Test-
Item Condition equipment Unit Terminal Unit Parts Method Specifications/Remarks
1. Setting 1) BATT terminal voltage:13.6V
2) SSG standard modulation
[Wide] MOD:1kHz,DEV:3kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
2. LCD contrast 1) Adj item:[CNTR] [Right Adjust the LCD contrast by
Adjust:[***] Up] looking.
Press [PF3] key to store the [Right Fixed Digit120
adjustment value. Down]
3. Assist voltage 1) Adj item:[RAST] [Right The display on the left of LCD
[RX] Adjust:[***] Up] shows PLL lock voltage. 3.0V