Text preview for : samsung_lw17m24c_chassis_vc17eo,_lw20m21c_chassis_ve20eo_service_manual.pdf part of Samsung lw17m24c chassis vc17eo, lw20m21c chassis ve20eo service manual Samsung LCD TV VC17EO chassis samsung_lw17m24c_chassis_vc17eo,_lw20m21c_chassis_ve20eo_service_manual.pdf



Back to : samsung_lw17m24c_chassis_ | Home

TFT-LCD TV
Chassis Model
VC17EO LW17M24C
VE20EO LW20M21C




SERVICE Manual

TFT-LCD TV CONTENTS
1. Precautions

2. Product Specifications

3. Disassembly & Reassembly

4. Alignment & Adjustments

5. Troubleshooting

6. Exploded View & Parts List

7. Electrical Parts List

8. Block Diagram

9. Wiring Diagram

10. PCB Layout

11. Schematic Diagrams

12. Panel Description
1 Precautions


1 Precautions
Follow these safety, servicing and ESD precautions to prevent damage and to protect against potential hazards such as electrical
shock.

1-1 Safety Precautions

1-1-1 Warnings
1. For continued safety, do not attempt to modify the circuit
(READING SHOULD
board. NOT BE ABOVE 0.5mA)


2. Disconnect the AC power and DC Power Jack before
servicing. DEVICE
LEAKAGE
CURRENT

1-1-2 Servicing the LCD TV
UNDER TESTER
TEST
TEST ALL
EXPOSED METAL
1. When servicing the LCD TV Disconnect the AC line SURFACES

cord from the AC outlet.
2-WIRE CORD
2. It is essential that service technicians have an accurate
voltage meter available at all times. Check the
calibration of this meter periodically. ALSO TEST WITH
PLUG REVERSED
(USING AC ADAPTER


1-1-3 Fire and Shock Hazard
PLUG AS REQUIRED) EARTH
GROUND



Before returning the LCD TV to the user, perform the Figure 1-1. Leakage Current Test Circuit
following safety checks:
1. Inspect each lead dress to make certain that the leads are 4. With the unit completely reassembled, plug the AC line
not pinched or that hardware is not lodged between the cord directly into a 220V AC outlet. With the unit's AC
chassis and other metal parts in the LCD TV. switch first in the ON position and then OFF, measure
2. Inspect all protective devices such as nonmetallic control the current between a known earth ground (metal water
knobs, insulating materials, cabinet backs, adjustment pipe, conduit, etc.) and all exposed metal parts,
and compartment covers or shields, isolation resistor- including: metal cabinets, screwheads and control shafts.
capacitor networks, mechanical insulators, etc. The current measured should not exceed 0.5 milliamp.
3. Leakage Current Hot Check (Figure 1-1): Reverse the power-plug prongs in the AC outlet and
WARNING: Do not use an isolation repeat the test.
transformer during
this test. 1-1-4 Product Safety Notices
Use a leakage current tester or a metering system that
Some electrical and mechanical parts have special safety-
complies with American National Standards Institute related characteristics which are often not evident from visual
(ANSI C101.1, Leakage Current for Appliances), and inspection. The protection they give may not be obtained by
Underwriters Laboratories (UL Publication UL1410, replacing them with components rated for higher voltage,
59.7). wattage, etc. Parts that have special safety characteristics are
identified by ! on schematics and parts lists. A substitute
replacement that does not have the same safety characteristics
as the recommended replacement part might create shock, fire
and / or other hazards. Product safety is under review
continuously and new instructions are issued whenever
appropriate.




LW17M24C/LW20M21C 1-1
1 Precautions

1-2 Servicing Precautions
WARNING: An electrolytic capacitor installed with the wrong polarity might explode.
Caution: Before servicing units covered by this service manual, read and follow the Safety Precautions
section of this manual.
Note: If unforeseen circumstances create conflict between the following servicing precautions and any of the safety
precautions, always follow the safety precautions.


1-2-1 General Servicing
Precautions 4. Check the insulation between the blades of the AC plug
1. Always unplug the unit's AC power cord from the AC and accessible conductive parts (examples: metal panels,
power source and disconnect the DC Power Jack before input terminals and earphone jacks).
attempting to: 5. Insulation Checking Procedure: Disconnect the power
(a) remove or reinstall any component or assembly, (b) cord from the AC source and turn the power switch ON.
disconnect PCB plugs or connectors, (c) connect a test Connect an insulation resistance meter (500 V) to the
component in parallel with an electrolytic capacitor. blades of the AC plug.
2. Some components are raised above the printed circuit The insulation resistance between each blade of the AC
board for safety. An insulation tube or tape is sometimes plug and accessible conductive parts (see above) should
used. The internal wiring is sometimes clamped to be greater than 1 megohm.
prevent contact with thermally hot components. Reinstall 6. Always connect a test instrument's ground lead to the
all such elements to their original position. instrument chassis ground before connecting the positive
3. After servicing, always check that the screws, lead; always remove the instrument's ground lead last.
components and wiring have been correctly reinstalled.
Make sure that the area around the serviced part has not
been damaged.




1-3 Electrostatically Sensitive Devices (ESD) Precautions
Some semiconductor (solid state) devices can be easily damaged by static electricity. Such components are commonly called
Electrostatically Sensitive Devices (ESD). Examples of typical ESD are integrated circuits and some field-effect transistors. The
following techniques will reduce the incidence of component damage caused by static electricity.

1. Immediately before handling any semiconductor 6. Do not remove a replacement ESD from its protective
components or assemblies, drain the electrostatic charge package until you are ready to install it. Most
from your body by touching a known earth ground. replacement ESDs are packaged with leads that are
Alternatively, wear a discharging wrist-strap device. To electrically shorted together by conductive foam,
avoid a shock hazard, be sure to remove the wrist strap aluminum foil or other conductive materials.
before applying power to the LCD TV. 7. Immediately before removing the protective material
2. After removing an ESD-equipped assembly, place it on a from the leads of a replacement ESD, touch the
conductive surface such as aluminum foil to prevent protective material to the chassis or circuit assembly into
accumulation of an electrostatic charge. which the device will be installed.
3. Do not use freon-propelled chemicals. These can Caution: Be sure no power is applied to
generate electrical charges sufficient to damage ESDs. the chassis or circuit and
4. Use only a grounded-tip soldering iron to solder or observe all other safety
desolder ESDs. precautions.
5. Use only an anti-static solder removal device. Some
8. Minimize body motions when handling unpackaged
solder removal devices not classified as "anti-static" can
replacement ESDs. Motions such as brushing clothes
generate electrical charges sufficient to damage ESDs.
together, or lifting your foot from a carpeted floor can
generate enough static electricity to damage an ESD.




1-2 LW17M24C/LW20M21C
2 Product Specifications


2 Product Specifications
2-1 LW17M24C, LW20M21C Specifications
Description
Item
LW17M24C LW20M21C

LCD Panel TFT-LCD panel, RGB vertical stripe, normaly white, 17-Inch viewable, 0.264 (H) x 0.264(V)mm pixel pitch TFT-LCD panel, RGB vertical stripe, normaly white, 20-Inch viewable, 0.2125(H) x 0.6375(V) mm pixel pitch

Scanning Frequency Horizontal : 30 kHz ~ 80 kHz (Automatic) Horizontal : 28 kHz ~ 33 kHz (Automatic)
Vertical : 50 Hz ~ 75 Hz (Automatic) Vertical : 50 Hz ~ 70 Hz (Automatic)

Display Colors 16.2 Million colors
Maximum Resolution Horizontal : 1280 Pixels Horizontal : 640 Pixels
Vertical : 1024 Pixels Vertical : 480 Pixels
Input Video Signal Analog 0.7 Vp-p