Text preview for : Topward 3000 Manual.pdf part of Topward series 3000 3303A Topward 30V 3A power supply manual. I will inc schematic / circuit as well



Back to : Topward 3000 Manual.pdf | Home

3000 Series
Operation Manual
3000 Series
Copyright
Copyright © 1995 by this company. All rights reserved. No part of this publication may be
reproduced in any form or by any means without the written permission of this company.



Disclaimer
This company makes no representations or warranties, either expressed or implied, with respect to the
contents hereof and specifically disclaims any warranties, merchantability or fitness for any particular
purpose. Further, this company reserves the right to revise this publication and to make changes from
time to time in the contents hereof without obligation of this company to notify any person of such
revision or changes.




ii
3000 Series
Table of Contents
1. Overview ................................................................................... 1

1.1 Introduction ....................................................................................... 1

1.2 Unpacking and Checking................................................................... 1

2. Front, Rear and Bottom Panels................................................... 2

2.1 Front Panels ..................................................................................... 2

2.2 Rear Panels and Bottom Panels........................................................ 5

3. Operation .................................................................................... 7

3.1 Pre-installation .................................................................................. 7

3.2 Setting the Output Voltage and Output Current.................................. 7

3.3 Constant Voltage/Constant Current Characteristics ........................... 8

3.4 Operation Modes .............................................................................. 8

3.4.1 Serial ...................................................................................... 8

3.4.2 Parallel.................................................................................... 9

4. Maintenance.............................................................................. 11
4.1 Changing the Fuse.......................................................................... 11

4.2 Changing the Voltage...................................................................... 11

5. Specifications ............................................................................ 12




iii
3000 Series
1. Overview
This 3000 Series Direct Current (DC) Power Supply Operation Manual contains an introduction to the
power supply, a description of its functions, the operation procedure, the scope of application and the
specifications. The models are the 3203A, 3203AR, 3203D, 3203DR, 3302A, 3302AR, 3302D,
3302DR, 3303A, 3303AR, 3303D, 3303DR, 3601A, 3601AR, 3601D, 3601DR, 3306D, 3306DR,
3603D, 3603DR, 33010D and 33010DR.


1.1 Introduction
The 3000 Series is a single-channel-output DC power supply with the following features:
· Constant voltage and constant current output
· Short circuit and external input protection
· Allows serial or parallel connection with the same power supply model


Special Functions on Remote Models

The following functions are available only on the remote models 3203AR, 3203DR, 3302AR,
3302DR, 3303AR, 3303DR, 3601AR, 3601DR, 3306DR, 3603DR and 33010DR:
· Output voltage readback
· Output current readback
· Remote or manual-controlled ON/OFF without using the power switch
· Control of output voltage and current using external voltage and resistor
· Remote sensing


1.2 Unpacking and Checking
Unpack and check that you have the following items:
· One power cable
· This Operation Manual
· Remote-Control Operation Manual (remote models only)
· One ACS-002 banana clip
· Two phone jacks (remote models only)
· Two 9-pin RS-232C connectors (remote models only)




1
3000 Series
2. Front, Rear and Bottom Panels

2.1 Front Panels




Front panel with digital
display for models
3203DR, 3302DR,
3303DR and 3601DR




Front panel with analog
meter for models
3203AR, 3302AR,
3303AR and 3601AR




2
3000 Series




Front panel with digital display for models 3306DR, 3603DR and 33010DR




Figure 1 Front Panels




3
3000 Series
(1) Power Switch: Power ON/OFF switch (1=ON, 0 = OFF)
(2) Output ON/OFF LED: Red LED for indicating output ON or OFF
(3) Output ON/OFF Switch: Output ON/OFF control switch (only available in remote models)
(4) -S Remote Sensing Input Terminal: For sensing output voltage at the - load terminal (only
available in remote models)
(5) Output Current Adjustment Knob: For adjusting output current at constant current (C.C.
Mode)
(6) - Output Terminal: Negative output terminal (black)
(7) + Output Terminal: Positive output terminal (red)
(8) Voltage Indicator
a) Analog: As indicated by the pointer on the 40x40mm (Class 2.5) meter
b) Digital: Displayed in full 3-digit red 0.52" LED
(9) C.V. Mode LED: Green LED to indicate constant voltage
(10) C.C. Mode LED: Red LED to indicate constant current
(11) Current Indicator
a) Analog: As indicated by the pointer on the 40x40mm (Class 2.5) meter
b) Digital: Displayed in full 3-digit red 0.52" LED
(12) Coarse Output Voltage Adjustment Knob: For adjusting output voltage at constant voltage
(C.V. mode)
(13) GND Terminal : Ground terminal (green)
(14) +S Remote Sensing Input Terminal: For sensing output voltage at the + load terminal (only
available in remote models)
(15) Fine Output Voltage Adjustment Knob: For fine adjustment of output voltage at constant
voltage (C.V. mode)
(16) Warning Label: The bare parts of the output terminals and fittings are electrical sensing parts.
Do not touch these parts during use.




4
3000 Series
2.2 Rear Panels and Bottom Panels




19
17
20
18




21




Rear and bottom panels for models 3203AR, 3203DR, 3302AR,
3203DR, 3303AR, 3303DR, 3601AR and 3601DR




5
3000 Series




Rear and bottom panels for models 3306DR, 3603DR and 33010DR



Figure 2 Rear and Bottom Panels
(17) D-Type 9-pin connector (RC1) for Remote Control
(18) D-Type 9-pin connector (RC2) for Remote Control

NOTE: Items 17 and 18 are available only on the remote models. Refer to the Remote-Control
Operation Manual for details.

(19) Power Input Socket
(20) Input Power Fuse Holder and Input Voltage Selector. Acceptable input voltage ratings are
100V, 120V, 220V and 240V. The selected input voltage is set to the position above the
mark (the rear panel above shows that the input voltage is set to 100V).
(21) Remote Control Function Switches: Only available on remote models. Refer to the Remote-
Control Operation Manual for details.




6
3000 Series
3. Operation

3.1 Pre-installation
Before you turn on the power:
· Check that the input voltage from your power source conforms to the voltage rating selected.
Refer to Input Voltage Selector in section 2.2. The tolerance is +10% of the indicated voltage
at 50/60 Hz.
· Place this power supply in a well-ventillated area and do not block the ventillation holes. Poor
heat dissipation leads to overheating which may cause unstable operation and shorten the
service life of this equipment.
· Be sure to use the correct fuse for your model. Refer to Table 1 for the type of fuse you
should use for a given voltage.


3.2 Setting the Output Voltage and Output Current
To set the output voltage and current, follow these steps:
1. Check that the total load to be connected does not exceed the maximum output voltage and
current of this power supply.
2. Open the circuit between the + and the - output terminals. Turn the voltage adjustment knob
clockwise to the desired output voltage rating.
3. Turn the current adjustment knob counterclockwise to get the minimum value.
4. Short the circuit between the + and the - output terminals. Note that the current rating of the
shorting wire should be greater than or equal to the required current.
5. Turn the current adjustment knob clockwise until the current indicator on the front panel
displays the required current rating.
6. Remove the shorting wire from the + and the - output terminals. The power supply returns to
the constant voltage mode and is ready to use.




7
3000 Series
3.3 Constant Voltage/Constant Current Characteristics
This power supply operates automatically between constant voltage (C. V. mode) and constant current
(C. C. mode) by responding quickly to rapid load changes. The following figures shows the relative
changes between the constant current and the constant voltage modes.

Constant Voltage



Crossover Point

Output
Voltage Constant
Current




Output Current


Figure 3 Constant Voltage vs. Constant Current Relation Diagram


3.4 Operation Modes

3.4.1 Serial

Serial connection allows the connection of two or more power supplies serially to obtain a higher
voltage rating (maximum 240V for this power supply).

For serial connection, it is recommended that all power supplies operate under the constant voltage
(C.V.) mode.

Figure 4 shows the serial connection between two 3303D power supplies. One unit is set at 30V/2A
and the other at 20V/3A. Figure 5 shows the serial connection voltage/current output versus load
changes.




8
3000 Series
SET : V1 = 30V / 2A
V SET : V2 = 20V / 3A

TOTAL OUTPUT VOLTAGE(VO)
50 V1 C.C. MODE

V V 40 V1 C.V. MODE V2 C.V. MODE
V1
30 V2 C.C. MODE
V2
20
A A 10
-S +S -S +S
- + - + 30 25 20 15 10 5 OHM

3A
V1 V2 2A

1A

V0=V1+V2 30 25 20 15 10 5 OHM




Figure 4 Serial Connection Diagram Figure 5 Serial Voltage/Current Output vs.
Load Change


3.4.2 Parallel
Parallel connection only allows thr connection of two or more power supplies of the same model to
obtain a higher current rating (maximum 24A for this power supply).

Figure 6 shows the parallel connection of two 3303D power supplies. One unit is set at 30V/3A and
the other at 20V/2.5A. Figure 7 shows the parallel connection voltage/current output versus load
changes.

SET : V1 = 30V / 3.0A
A SET : V2 = 20V / 2.5A
[V1&V2 C.C. MODE]
[V1 C.C. MODE
V V 6A V2 C.V. MODE]

[V1&V2 C.V. MODE]
4A
A A
-S +S -S +S

- + - +
2A

1 2 4 6 8 10 30 OHM

I1 I2 V

30

20
IO
IO=I1+I2 10
- + 1 2 4 6 8 10 30 OHM

Figure 6 Parallel Connection Diagram Figure 7 Parallel Voltage/Current Output vs.
Load Change




9
3000 Series
NOTE: The difference between the voltage settings for two or more power supplies of the same
model connected in parallel should not exceed 15V. The minimum voltage setting should
not be lower than 10V. If it is necessary to be lower than 10V, the voltage difference
should be less than 2V. The closer to 0V the smaller the difference required.




10
3000 Series
4. Maintenance

4.1 Changing the Fuse
The fuse is located inside the input power fuse holder (refer to Figure 2). You need to change the
fuse when:

· the fuse is blown out

· you change the voltage rating

In any case, replace the fuse with one of the same rating. Refer to Table 1 for the type of fuse used for
each model and voltage.

NOTE: Unplug the power cord before you change the fuse.


4.2 Changing the Voltage
To change the voltage, follow these steps:
1. Use a flathead screwdriver to detach the Input Power Fuse Holder and Input Voltage Selector
unit (refer to Figure 2).
2. Turn the unit so that the desired input voltage is positioned above the mark.
4. Check that the fuse to conform to this new voltage rating. Refer to Table 1 below for the
correct fuse rating.
5. Replace the Input Power Fuse Holder and Input Voltage Selector unit.

Table 1 Power Supply Weight , Dimensions and Fuse Specification

Model Weight (Approx.) Dimension Fuse
WxH xD (mm) Time-Delay Type 6 x 30 mm
Net Gross Machine Package 100V 120V 220V 240V
3203A/AR/D/DR 4.3 KG 5.5 KG 120x160x200 239x265x394 2A 2A 1A 1A
3302A/AR/D/DR 4.3 KG 5.5 KG 120x160x200 239x265x394 2A 2A 1A 1A
3303A/AR/D/DR 4.3 KG 5.5 KG 120x160x200 239x265x394 2A 2A 1A 1A
3601A/AR/D/DR 4.3 KG 5.5 KG 120x160x200 239x265x394 2A 2A 1A 1A
3306D/DR 8.6 KG 10.1 KG 230x160x324 364x265x422 4A 4A 2A 2A
3603D/DR 8.6 KG 10.1 KG 230x160x324 364x265x422 4A 4A 2A 2A
33010D/DR 13 KG 14.4 KG 230x160x366 364x265x464 8A 8A 4A 4A




11
3000 Series
5. Specifications
Model 3203A 3302A 3303A 3601A 3306D 3603D 33010D
Specification 3203D 3302D 3303D 3601D
Output Voltage 0-20V 0-30V 0-30V 0-60V 0-30V 0-60V 0-30V
Output Current 0-3A 0-2A 0-3A 0-1A 0-6A 0-3A 0-10A
CONSTANT VOLTAGE CHARACTERISTICS
Load Regulation ± 0.01% +2mV
Line Regulation ± 0.01% +2mV
Ripple & Noise (100W) 0.5mVrms
Ripple & Noise (100W) 1mVrms
CONSTANT CURRENT CHARACTERISTICS
Load Regulation (100W) 10mA
Load Regulation (100W) 15mA
Line Regulation ± 0.01% +2mA
Ripple & Noise (100W) 1mArms
Ripple & Noise (100W) 3mArms
DISPLAY ACCURACY
Analog Display (A) Full-scale 3%
Digital Display (D) 0.1% +2d
PROGRAMMING SPEED
Rise Time (No Load) 100mS
(Load) 200mS (<6A), 500mS (<10A), 1S (10A)
Fall Time (No Load) 2.5S
(Load) 250mS
OUTPUT IMPEDANCE < 2m + 2H
RECOVERY TIME 100S to within 0.1% of set voltage (50% to 100% load change)
FUNCTIONS
Series Connection Different models can be connected in series (240V)
Parallel Connection Same models can be connected in parallel ( 24 A)
Master - Slave N/A
POWER SOURCE ACV 100/120/220/240 ±10%, 50/60Hz
ACCESSORIES ACS-002 X1
DIMENSIONS 120 X 160 X 200 230 X 160 X 324 230 X 160
W X H X D (mm) X 366




12
3000 Series

Model 3203AR 3302AR 3303AR 3601AR 3306DR 603DR 33010DR
Specification 3203DR 3302DR 3303DR 3601DR
Output Voltage 0-20V 0-30V 0-30V 0-60V 0-30V 0-60V 0-30V
Output Current 0-3A 0-2A 0-3A 0-1A 0-6A 0-3A 0-10A
CONSTANT VOLTAGE CHARACTERISTICS
Load Regulation ± 0.01% +2mV
Line Regulation ± 0.01% +2mV
Ripple & Noise (100W) 1mVrms
Ripple & Noise (100W) 2mVrms
CONSTANT CURRENT CHARACTERISTICS
Load Regulation (100W) 10mA
Load Regulation (100W) 15mA
Line Regulation ± 0.01% +2mA
Ripple & Noise (100W) 1mArms
Ripple & Noise (100W) 3mArms
DISPLAY ACCURACY
Analog Display (A) Full-scale 3%
Digital Display (D) 0.1% +2d
PROGRAMMING SPEED
Rise Time (No Load) 100mS
(Load) 200mS (<6A), 500mS (<10A), 1S (10A)
Fall Time (No Load) 2.5S
(Load) 250mS
OUTPUT IMPEDANCE <2m + 2H
RECOVERY TIME 100S to within 0.1% of set voltage (50% to 100% load change)
FUNCTIONS
Serial Connection Different models can be connected in series (240V)
Parallel Connection Same models can be connected in parallel (24A)
Master - Slave Yes
REMOTE CONTROL
Voltage Programmable
By External DC Voltage 0 to 10V, Control 0 to voltage setting
By External Resistance 0 to 10K, Control 0 to maximum voltage
Current Programmable
By External DC Voltage 0 to 10V, Control 0 to current setting
By External Resistance 0 to 10K, Control 0 to maximum current
VOLTAGE/CURRENT READBACK AVAILABLE
Voltage Readback 0 to 10V for full-scale voltage
Current Readback 0 to 0.3V for full-scale current
OUTPUT ON/OFF CONTROL YES
REMOTE SENSING Compensate voltage drop Up to 2VDC
POWER SOURCE ACV 100/120/220/240 ±10%, 50/60Hz
ACCESSORIES ACS-002 X1, phone-jack plug X2, 9-pin D-type connector X 2
DIMENSIONS 120 X 160 X 200 230 X 160 X 324 230 X 160
W X H X D (mm) X 366