Text preview for : HFP0460.PDF part of Sony HFP0460 Sony HiFi Service Bulletin HFP0460.PDF



Back to : HFP0460.PDF | Home

Hi-Fi Products CSA-13
Service Bulletin
Sony Service Company - Technical Services
A Division of Sony Electronics Inc.
Sony Drive, Park Ridge, New Jersey 07656


Model: HCD-C33/C55 No. 460
Subject: Initialization Information Date: November 27, 1995


Symptom:
(**) Sequence of events during Initialization




Reference: Tokyo fax PRINTED IN USA
Autoflagged - NO
PRINTED ON RECYCLED PAPER
Hi-Fi Products Service Bulletin No. 460




Tray Open/Stock-In Function
Begin - Open/Stock-In


Wait for completion of Open (CF1*)/Stock-In(CF2*)cycle.


100 msec. Brake


150 msec PWM push


100 msec Brake (again)


Confirm - Open/Stock In Completion


If Open/Stock-In Completion If no Open/Stock Completion


End Push with PWM


*Cf1= Open Completion (Out-SW is On or closed, and In-SW is OFF or open)
*Cf2= Stock-In Completion (Stock-In-SW is ON or closed)
Hi-Fi Products Service Bulletin No. 460



Tray Closed/Stock -Out Function
Begin Close/Stock-Out


Wait for close (Cf3*)/Stock-Out (Cf4*)completion


40 msec reverse Turning


After 100 msec braking, confirm Close/stock-out Completion


If Close/Stock-out Completion If not Close/Stock-Out Completion

Begin Close/Stock-Out (again)

Wait for Close/Stock-out Completion

After 100 msec braking, confirm
Close/Stock-out

If confirmed If not confirmed

Positioning of tray in Mid position by PWM

End, with elevator at Mid position

*Cf3= Open Completion (Out-SW is OFF or opened, and In-SW is ON or closed)
*Cf4= Stock-Out Completion (Mid-Sense, photo sensor, is On or Mid-Sw is OFF)
Hi-Fi Products Service Bulletin No. 460



Positioning of Tray in a Mid Position


Confirm Mid Position* If yes, End


If not at Mid Position


Judge direction by Mid-Sw ON/OFF, Move tray by PWM


When in Mid Position, apply braking for 100 msec

* Mid Position = (Mid-Sense, photo sensor, is ON).
Hi-Fi Products Service Bulletin No. 460



Elevator Up & Down Movement
When Count SW is OFF, "Mechanism Initialization" will scroll across display
When Count SW is ON


Compare the Current disc and Target disc If same End


If Discs are different


Move UP or DOWN Toward the target Disc


Wait for Count SW OFF If not OFF in 5 sec., 1st time, it will try a
second time by mechanically reversing until
the Count SW is OFF. If not, then
Mechanical Error" is displayed.

If Count SW OFF within 5 sec.


Wait for Count SW ON If not ON in 5 sec., 1st time, it will try a
second time by reversing until Count SW is
ON. If not, then "Mechanical Error" is
displayed

If Count SW is ON in 5 sec


Current Disc = Target Disc If Current disc is not If Current Disc
is not
Target Disc, and Target Disc, and
Reverse is necessary. Forward is necessary.

100 msec braking


100 msec braking


If Count SW = H, "Mechanical Initialization" is displayed
If Count SW = L, End.
Hi-Fi Products Service Bulletin No. 460




Main Protection Functions
1.) When Opening the Tray
If Count -SW is OFF, it triggers Mech Initialization.
If it does not finish opening the tray in 6 sec, it will reverse and close the tray.

2.) When Closing the Tray
If it does not finish closing the tray in 6 sec, it will reverse and open the tray.

3.) When Stock-In or Stock-Out
If Count SW is OFF, it triggers Mech Initialization.
If it does not complete Stock-In/Stock-Out in 6 sec, it will bring the tray back to Mid
Position. This function does have 6 sec time limit and if it does not comeback into the
Mid Position within 6 sec., it will trigger a "Mechanical Error" message. If it is back
with in 6 sec., it will try Stock-In/Stock-Out once again. If it times out, it triggers a
"Mechanical Error" message.


Mechanical Initialization

When the A/C cord is first connected, the CPU does not know the status of the CD
Mechanism. Therefore, it goes into "Mechanical Initialization" which is as follows: