Text preview for : 5991-3513EN Beam Lead Diode Bonding and Handling Procedures - Application Note c20140827 [3].pdf part of Agilent 5991-3513EN Beam Lead Diode Bonding and Handling Procedures - Application Note c20140827 [3] Agilent 5991-3513EN Beam Lead Diode Bonding and Handling Procedures - Application Note c20140827 [3].pdf
Back to : 5991-3513EN Beam Lead Dio | Home
Keysight Technologies
Beam Lead Diode Bonding and
Handling Procedures
Application Note
02 | Keysight | Beam Lead Diode Bonding and Handling Procedures - Application Note
1.0 ESD Considerations 5.0 Bonding
A beam lead diode can be destroyed electrically by a static (or See Beam Lead Attachment Methods - Application Note,
other) discharge through the device. It must therefore be handled publication number 5091-9074E for a general description of the
so these effects cannot occur. Normal electrostatic discharge various methods for attaching beam lead diodes to both hard and
(ESD) preventive measures should be incorporated into all as- soft substrates.
pects of the storage, handling, and assembly of these devices.
Specific measures to be taken should include: Thermocompression