Text preview for : TDSHT3_Quick_Ref_Card_SinkTest.pdf part of Tektronix TDSHT3 Quick Ref Card SinkTest Tektronix TDS7000 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 TekScope_Opt_App_1.0.10_071-1883-01_063-3914-10 Documents HT3-1.2a_Documentation TDSHT3_Quick_Ref_Card_SinkTest.pdf



Back to : TDSHT3_Quick_Ref_Card_Sin | Home

Getting Started with TDSHT3 4. The software remotely controls the DTG and AWG, 6. To configure and test the GPIB connection to the DTG,
which must be connected by a National Instruments click Signal Sources. The Signal Sources Setup dialog
You can use this side of the quick reference card to get GPIB-USB-B. To connect the DUT, click Tests > box appears.
started with the Sink Jitter Tolerance test procedure. The Connect.
other side contains a complete menu tree for the TDSHT3
HDMI Compliance Test Software.

NOTE. For additional procedures, refer to the
TDSHT3 Quick Start User Manual. For
complete operating instructions, refer to the
online help.


TDSHT3 HDMI Compliance Test Software enables
unprecendented efficiency by providing a comprehensive 5. Make the connections as follows:
range of tests, including Jitter Tolerance. 7. To run the test successfully, ensure that the Bus Timing
To find the device tolerance limit parameter is set to 2 usec on your GPIB board
Sink Jitter Tolerance configuration.
This test allows you to confirm that the maximum allowed 8. Click Run Test to perform the test. The TDSHT3
TMDS clock jitter is supported by the Sink DUT. HDMI Compliance Test Software sets up the
oscilloscope and conducts the test. Follow the
You will need one supported oscilloscope, two differential instructions in the dialog box. Depending on your
probes, one digital timing generator (DTG), one arbitrary answer, a series of dialog boxes may prompt you for
waveform generator (AWG), one DC power supply, 12 your input.
SMA cables, two bias-tees, one cable emulator, one GPIB
controller, one TPA-R-DI, and one TPA-R-TDR. 9. If you successfully run the test, the software calculates
the jitter values and displays the results. The software
Follow these steps: makes Result available automatically and displays the
result summary, the eye diagram plot, and the clock jitter
1. On the menu bar, click Tests > Select > Sink. plot. You can also view the report configuration details
2. In the differential tests pane, select the Jitter Tolerance in the result pane.
check box.




To measure the parameters




3. To change the configuration settings, click Tests > 10. In the result summary pane, click Result Details to
Configure. For most tests, you can use the factory display the results of the tests.
default configuration. However, you can change the
values by using the virtual keyboard or the general
purpose knob on the oscilloscope front panel. Using the
File menu, you can also restore the factory defaults or
save and recall your own configuration settings.




For up-to-date information on Tektronix oscilloscope To order along with oscilloscope:
solutions for HDMI Compliance Test Software, access
H Opt. HT3 - HDMI Compliance Test Software
the www.tektronix.com Web page.
To order an upgrade for an existing oscilloscope:
TDSHT3 Ordering Information
This software supports the TDS6000B, TDS6000C, H TDS6000B - Order TDS6BUP - Opt. HT3
TDS7254/B, TDS7404/B, CSA7404/B, TDS7704B, and H TDS7000/B - Order TDS7UP/7BUP - Opt. HT3
DPO/DSA70000 series of oscilloscopes. Refer to the H CSA7000/B - Order TDS7UP/7BUP - Opt. HT3
Optional Applications Software on Windows-Based
Oscilloscopes Installation Manual for a list of specific Recommended Accessories
models. The applications CD includes a PDF file of the
online help. Oscilloscopes
H 16M Record Length/Ch - Opt. 4M or more (for Eye
Diagram and Jitter tests)
H Serial Trigger - Opt. ST (for Inter-pair Skew tests)
HDMI Pattern Sources
H Jitter Generation - AWG710B (for Sink tests)
H Test Pattern Generation - DTG5274 and DTGM30 for
Sink Tests (three required)
TDR Tests
H Oscilloscope - TDS8000B with 80E03 and 80E04
modules
TDSHT3
Probes HDMI Compliance Test Software
H Differential Probes - P6330, P7330, P7350 (two probes Reference
required), and P7380
H Active Probes - P7240 and above (two probes required) Sink Test
H Probe Positioner - PPM100 Flexible Arm Probe Posi-
tioner
Test Fixtures
H Plug type - HDMI TPA-P adapter set - 013-A013-50
H Receptacle type - HDMI TPA-R adapter set -
013-A012-50




www.tektronix.com
*P071196001*
071-1960-01
TDSHT3 Menu Tree
Recall Default
Recall
Save
File Recall Recent Position Eye Mask in Center
Preferences Acquisition Alert Message
Minimize Pulse Width
Trigger (Rise/Fall Time or Over/Undershoot)
Exit Edge Trigger

Eye Diagram
Source Duty Cycle
Select Sink Rise Time
Cable Fall Time
Clock Jitter
Over/Undershoot VH
Source Over/Undershoot VL
InterPair Skew (ClockData Tests)
InterPair Skew (DataData Tests)
IntraPair Skew
Low Amplitude +
Tests Configure Low Amplitude

Min/MaxDiff Swing Tolerance
Sink Jitter Tolerance
IntraPair Skew

Cable Eye Diagram
Connect

View Waveform


Summary
Results Details
Define Test Template
Utilities Report Generator Define Report Layout
Deskew Generate Report

Help Help Topics
About TDSHT3