Text preview for : classe_300x.pdf part of Bticino Classe 300X Bticino Classe 300X Video internal unit Installation Manual



Back to : classe_300x.pdf | Home

Classe 300X

Installation Manual




www.bticino.com
Classe 300X
Installation Manual
Classe 300X
Installation Manual




Contents General information 4
Warnings and recommendations 4
Front view 5
Rear view 7
Dimensional data and installation heights 8
Wall-mounted installation 9
Installation on the table-top base 10
Physical configuration 12
Configurators 13
Functions of the M units configurator (Favorites key) 14
Functions of the M tenths configurator (Quick actions) 15
First switching on 19
Settings 21
General settings 21
Ringtones 30
Display 31
Answering machine 33
Quick actions 35
Configuration 37
Advanced Configuration 40
First switching on 40
Configuration 43
General settings 45
Intercom 45
Camera 47
Activation 49
Quick actions 51
Factory configuration 53
TROUBLESHOOTING 54




3
Classe 300X
Installation Manual


General information
Warnings and recommendations
It is important to read this manual carefully before proceeding with the installation.
The guarantee automatically expires for negligence, misuse, tampering by unauthorized
personnel.
The Classe 300X Video internal unit must only be installed indoors; it must not be exposed to water
drops or splashes; it must be used only on BTicino 2 wire digital systems.
The Classe 300X video internal unit must be connected to a Wi-Fi network with the following
features:
­ IEEE 802.11 b/g/n (2,4 GHz) 13 canali
­ Metodo di criptazione ed autenticazione supportati:
­ IEEE 802.11 b/g/n (2,4 GHz) 13 channels
­ Encrypting and authentication methods supported:
­ OPEN WPA-PSK networks
­ TKIP WPA2-PSK included
­ included AES WEP 64 bits (ASCII 5 figure or hexadecimal 10 figure codes)
­ WEP 128 bits (ASCII 13 figure or hexadecimal 26 figure codes)
­ WPS authentication (supported for WPA2-PSK)
NOTE: a domestic Wi-Fi with internet access is needed for the connection between the Classe 300X
video internal unit and the smartphone.
To use the service, the Customer must acquire the technical equipment which allows access to the
Internet, on the basis of an agreement made by the Customer himself with an ISP (Internet Service
Provider). BTicino plays no part in this.
The customer must install the DOOR ENTRY APP on his smartphone so that he can use some services
which BTicino supplies as extras to the normal basic functions of the Classe 300X.
The services offered by means of the APP require being able to interact with Classe 300X remotely and
through the Internet.
In these cases the integration and good working between Classe 300X and APP may depend on:
­ a) quality of the Wi-Fi signal;
­ b) type of access contract to the home internet;
­ c) type of data contract on the smartphone.
When one of these 3 elements does not conform with the specifications required for product operation,
BTicino accepts no responsibility for any faults.
The product in fact supports a VoIP streaming system. You must therefore check with your smartphone
data network contract that it does not block it.
We would like to inform you that the service provided by BTicino by means of remote use via the APP
involves the use of data. The cost linked to data usage depends on the type of contract which the
customer has with his ISP (Internet Service Provider) and is solely the customer's responsibility.

Hello, my name is BTTrick and my job is to help you with the device configuration.
Hello, my name is BTTrick and my job is to help you with the device configuration.
In this manual the standard configurations are simple and well explained, but I want to
In this manual the standard configurations are simple and well explained, but I want to
teach you the "tricks" to use your new Classe 300X at its best.
teach you the "tricks" to use your new Classe 300X at its best.
When you find the symbol , move the mouse over it.




4
Classe 300X
Installation Manual


Front view
1 2 3 4 5 6 7 8 9 10




10:36
Tuesday, 22 April


Download the Door Entry App
Quick Actions
Are there controls that are
used more often than others?
Put them in the main page of Private camera


your device in order to have
them always at your disposal 20
Answering machine Cameras Memo External intercom
11

Pager



Intercom Activations Settings
Lock


19
18
17




12 16 15 14 13 12
Note: The image* shows the device with all its functions enabled.
In this manual check how to enable them.
* The background and icons shown may differ from those on the device.

1. 7" touch screen display (16 : 9)
2. Screen OFF key
3. App:
touch to display the information page where you find a QR code that allows the download of
the DOOR ENTRY APP to interact with your device.
It is possible to disable the information page display.
4. Time and date
5. Wi-Fi Connection
6. Device/APP association and enabled/disabled forwarding of calls
7. Ringtone exclusion
8. Professional Studio (Office) activation
9. Microphone
10. Answering machine activation
11. Quick actions
12. Tactile guides
13. Connection key:
The green LED flashes to indicate an incoming call
The green LED comes on steady to indicate that there is an active call
14. Auto-switching on/Scrolling:
the red LED turns on when the key is pressed




5
Classe 300X
Installation Manual


15. Favorites key:
the red LED turns on when the key is pressed
(Basic configuration = STAIRCASE LIGHT. For a different configuration refer to the physical
configuration table)
16. Door lock release key:
the red LED turns on when the key is pressed
Are you sure that your Router is 17. Wi-Fi Status:
switched on? Red LED flashing = Wi-Fi is active but not connected to a network
LED off = disabled or properly functioning Wi-Fi
Green LED steady = the Classe 300X is exchanging data with the DOOR ENTRY APP (forwarding
of call, auto-switching on)
Note: when the DOOR ENTRY APP is connected to the system (e.g. answer a call, display an Entrance
If the Wi-Fi LED is green Panel, etc.), no operations can be made, with the exception of the door lock release key and Favorite Key
and steady, another user is (configured for the Staircase Light or Door Lock Direct Control functions) that continue to operate.
connected at home, wait 1
minute before using your
18. Message status:
Classe 300X or wait until the
Red LED flashing = new unread note/s or message/s in the answering machine
LED is switched off.
19. Bell exclusion Status:
Red LED on = Call ringtone disabled
20. Functions (only the icons for the configured functions are displayed)




6
Classe 300X
Installation Manual


Rear view
123




4
5




6 6




10 9 8 7
1. Configurator socket
2. Configurator J1: Remove if the additional power supply is present (clamp 1 and 2)
3. Configurator J2: for correct operation do not remove
4. Line termination ON/OFF micro-switch
5. Mini USB socket for device Firmware update using the MyHomeSuite software
Note: the device must be powered (1-2 or BUS)
6. Loudspeaker
7. Additional power supply clamps (1 - 2)
8. 2 WIRE SCS/BUS connection clamps
9. Clamps ( ) for the connection of an external call to the floor pushbutton
10. Additional ringtone connection clamps (1 - 5M)
Point-to-Point connections are required on the clamps of the additional ringtones




7
Classe 300X
Installation Manual


Dimensional data and installation heights

194 mm 25 mm


10:36
Luned́, 22 Aprile


Download the Door Entry App
Quick Actions



Private camera




Answering machine Cameras Memo External intercom
162 mm




Pager



Intercom Activations Settings
Lock




160 ­ 165 cm
135 ­ 140 cm




Altezza consigliata salvo diversa normativa vigente




8
Classe 300X
Installation Manual


Wall-mounted installation




1




2




3




4




Caution: avoid fastening the bracket on uneven or irregular surfaces and excessive screw tightening, in
order to prevent any bracket distortion that may compromise the correct installation of the device. The
device must slide in the appropriate bracket rails with a slight pressure and without straining.




9
Classe 300X
Installation Manual


Installation on the table-top base




Position the microswitch on ON to terminate the line.




ns
tio
Ac
ick
Qu
e
:36 ril era
10 22 Ap c am
d ́, te
va
ne Pri
Lu pp
yA om
E ntr terc
or al in
Do Ex
tern
d the
loa
wn
Do r
ge
Pa
mo
Me
ck
Lo
ras
me
Ca

ine
ch gs
ma ttin
ng Se
eri
sw
An
o ns
ati
tiv
Ac


m
rco
Inte




8-way socket:
336982/83/84 Livinglight
349414/15/18 Axolute



1 5
1-2 BUS
78
1-2 1 25 6 BUS
56

56
78 2 36 7
3 47 8
4 8


10
Classe 300X
Installation Manual


Wi-Fi installation requirements
Check the Wi-Fi signal quality from the device display (see the Installer Manual). If it is low or does
not exist, make sure that:
­ the device is not installed near large metal objects or electric devices that can generate
electromagnetic field;
­ there are fewer possible walls between the router/access point and the Classe 300X.
Note: it is recommended that the Classe 300X is installed near the Wi-Fi router.
Note: it is possible to install just one Classe 300X for each Wi-Fi (SSID) network.
Note: it is possible to install just one Classe 300X for apartment
1
Suggested

Always check the Wi-Fi signal on the device display before
final installation of the objects.

The device has been correctly connected to the Wi-Fi
network and configured in the appropriate section.

The Wi-Fi signal is not sufficient to ensure the correct
call transfer and other smartphone features.
Check the Wi-Fi installation requirements




Install the router in the same
room with your Classe 300X 1




­ Partition masonry walls ­ Walls in reinforced concrete
­ Wood walls ­ Load-bearing walls
­ Plasterboard walls ­ Stone walls
­ Metal walls




11
Classe 300X
Installation Manual


The physical configuration
is faster and it is suitable Physical configuration
for standard systems, e.g. The device must be configured both physically or in advanced mode, the main differences are
apartment blocks; use the shown in the following table:
advanced configuration for
more complex systems Note: the connection of the configurators to the N - P - M sockets precludes the possibility of using the
advanced configuration.

The configuration must be performed with the device disconnected from the power supply.
Before using it, wait for the LEDs to stop flashing.

Available Functions Physical Configuration Advanced Configuration

FAVORITES KEY Possibility of assigning various functions Staircase Light function


See "Functions of the M units
configurator (Favorites key)"

QUICK ACTIONS Preset: Creating quick actions of all
functions

See "Functions of the M tenths
Private camera
configurator (Quick actions)"

The user can rename, delete and add The user can decide the quick
External intercom
back, only the preset functions actions to display in the home
page
Pager


Are there controls that are
used more often than others? Lock

Put them in the main page of
your device in order to have FUNCTIONS The use of the functions is only available Dedicated icons in the home
them always at your disposal through quick actions in the home page page and customisable,
configurable functions

See "Functions of the M tenths
configurator (Quick actions)" See "Configuration"
Cameras




Intercom




Activations




12
Classe 300X
Installation Manual


Configurators




1 2 3 4 5



J1 J2 N P M




The additional power supply Configurator functions
is necessary for all the devices 1. J1 = Remove if the additional power supply is present (clamp 1 ­ 2)
but one (main) on which, when
2. J2 = For correct operation do not remove
a call arrives, the video picture
and the ringtone switch 3. NN = Device address
on. The main device always
4. PP = Address of the EP of which you can open the Door Lock with IU idle, and to which you can
switches off even without
send the auto-on command
additional power supply. If
instead the simultaneous 5. MM = Mode of operation according to the tables on the following pages
switching on of all devices is M units = Configuration of the FAVORITES capacitive key
not necessary, define the main M tenths = Configuration of the QUICK ACTIONS in the Home page
(MASTER) and the secondary
(SLAVE) devices with the Note: If the device is configured physically, the configuration MUST NOT BE MODIFIED using the menu.
appropriate jumpers




13
Classe 300X
Installation Manual


Functions of the M units configurator (Favorites key)
J1 J2 N P M P+1 MOD=9
P+1
P+1 MOD=9
P+1
P+1

P+1 MOD=9




P+2
P+2 MOD=9
P+2
P+2 MOD=9
P+2
P+2 MOD=9




MM = 0 Staircase Light Control P+3
P+3 MOD=9
P+3
P+3 MOD=9
P+3
P+3 MOD=9




P+1
P+1
P+1
MM = 1 Direct control of P+1 Door lock 1

1



1

1




346210
1

1
2




2




2
2
2




2
3




3




3
3




3




3



346210




346210




P+1 P+1
P+1 P+1
P+1
MOD=5P+1
MOD=5
MOD=5


P+2
P+2
P+2
MM = 2 Direct control of P+2 Door lock
1 2 3

1 2 3



1 2 3

1 2 3




346210
1 2 3

1 2 3


346210




346210




P+2 P+2
P+2 P+2
P+2
MOD=5P+2
MOD=5
MOD=5


P+3
P+3
1 2 3
P+3
1 2 3




MM = 3 Direct control of P+3 Door lock
1 2 3

1 2 3




346210
1 2 3

1 2 3


346210




346210




P+3 P+3
P+3 P+3
P+3
MOD=5P+3
MOD=5
MOD=5
P

P 1

1 2
2

3
3




MM = 4 P+1 direct auto-switching on P
346210




1 2 3




P+1
1 2 3




P+1 MOD=9
346210




1 2 3




P+1
1 2 3




P+1 MOD=9
346210




1 2 3

1 2 3




P+1
P+1
346210




MOD=9
1 2 3




P+2
1 2 3




MM = 5 P+2 direct auto-switching on P+2 MOD=9
346210




1 2 3




P+2
1 2 3




P+2 MOD=9
346210




1 2 3

1 2 3




P+2
P+2 MOD=9
346210




1 2 3




P+3
1 2 3




P+3 MOD=9
346210




1 2 3




P+3
1 2 3




MM = 6 P+3 direct auto-switching on P+3 MOD=9
346210




P+3
P+3 MOD=9




MM = 7 Paging




MM = 8 Internal intercom




Enabling/disabling Professional Studio (Office)
MM = 9
function




14
Classe 300X
Installation Manual


Functions of the M tenths configurator (Quick actions)
The MM - (tenths) physical configurator decides which are the 4 QUICK ACTIONS icons that appear
on the HOME PAGE, and can be activated by touching the display.
P
P
J1 J2 P N
P
P M
­+ 1 23 4




­+ 1 23 4




P+1
P+1 MOD=9
­+ 1 23 4




P+1
P+1 MOD=9
­+ 1 23 4




P+1
P+1 MOD=9
P+1
P+1 MOD=9
­+ 1 23 4




The possible configurations are shown in the following table
P+2
­+ 1 23 4




P+2 MOD=9
­+ 1 23 4




P+2
P+2
P MOD=9
P+2
­+ 1 23 4




P+2 MOD=9
P+2
P+2 MOD=9 Activation of the EP (configured with P+1) directly without call or
1 2 3

1 2 3




activation of the actuator item 346200/346210 (configured with P+1 and
­+ 1 23 4




346210




P+3
­+ 1 23 4




P+3 P+1
MOD=9 MOD=9).
P+1 MOD=9
­+ 1 23 4




P+3
P+3 MOD=9
P+3
­+ 1 23 4




P+3 MOD=9
P+3
P+3 MOD=9
­+ 1 23 4




P+2
P+1
EP door lock release (configured with P+1), directly without call, or
P+2 MOD=9
P+1 activation of the actuator item 346200/346210 (configured with P+1 and
P+1
1 2 3

1 2 3




P+1
346210

1

1 2
2

3
3



MOD=5), or activation of door lock actuators item 346230 (configured
with P+1)
346210
1 2 3




P+1 P+1
1 2 3




­+ 1 23 4



346210

1 2 3




MOD=5P+1
1 2 3




P+1 P+3
P+3 MOD=9
346210




MOD=5P+1
P+1
MOD=5P+1
P+1
MOD=5
P+2
P+2
EP door lock release (configured with P+2), directly without call, or
P+2 activation of the actuator item 346200/346210 (configured with P+2 and
1 2 3

1 2 3




346210




P+2
2 3




P+1
1

1 2 3




346210




P+2 P+2
1

1
2

2 3
3




MOD=5), or activation of door lock actuators item 346230 (configured
with P+2)
346210
1 2 3
1 2 3




MOD=5P+2
1 2 3
1 2 3




P+2
346210
346210




MOD=5P+2
P+2
P+1 P+1
MOD=5P+2
P+2
MOD=5
MOD=5
P+3
P+3
1

1 2
2

3
3




P+3 EP door lock release (configured with P+3), directly without call, or
P+2
activation of the actuator item 346200/346210 (configured with P+3 and
346210




P+3
1 2 3

1 2 3




346210
1 2 3




P+3 P+3
1 2 3




MOD=5), or activation of door lock actuators item 346230 (configured
1 2 3

1 2 3




346210

1 2 3




MOD=5P+3
1 2 3




P+3
346210




with P+3)
346210




MOD=5P+3
P+3
P+2 P+2
MOD=5
P+3
MOD=5 P+3
MOD=5
P+4
P+4
P+4
P+3
1 2 3

1 2 3




346210

1

1 2
2

3
3




P+4
EP door lock release (configured with P+4), directly without call, or
activation of the actuator item 346200/346210 (configured with P+4 and
2
1 346210 3
1 2 3
1 2 3




P+4 P+4
1 2 3




346210

346210

1 2 3




MOD=5P+4
1 2 3




P+4 346210




P+3 P+3
MOD=5P+4
P+4
MOD=5), or activation of door lock actuators item 346230 (configured
MOD=5
MOD=5P+4
P+4 with P+4)
MOD=5

P+4
1 2 3

1 2 3




346210




Intercom among apartments in systems with apartment interface item
P+4 P+4
MOD=5 346850.



Intercom inside the apartment, in systems with apartment interface item
346850, or intercom among apartments in systems without apartment
interface.



Internal intercom. It sends the call to all the handsets with the same
address.




Paging, makes a general intercom. It sends the call to all the handsets of
the system.




15
Classe 300X
Installation Manual



P M P M P M

0 1 0 2 0 3




Myself Pager Myself




Poste externe 1 Camera 1 Intercom 1




Lock 1 Lock 1 Camera 1




Lock 2 Lock 2 Lock 1




N=1 N=2




1 2 3 1 2 3

1 2 3 1 2 3




346210 346210




N=2 N=1
P+1 P+1
P+1 MOD=9 P+1 MOD=9




P+1 P+1 1 2 3

1 2 3




1 2 3 1 2 3 346210

1 2 3 1 2 3




346210 346210




P+1
P+1 P+1 P+1 P+1
P+1 MOD=9
MOD=5 MOD=5




P+2 P+2 P+1
1 2 3 1 2 3 1 2 3

1 2 3 1 2 3 1 2 3




346210 346210 346210




P+2 P+2 P+2 P+2 P+1 P+1
MOD=5 MOD=5 MOD=5




16
Classe 300X
Installation Manual



P