Text preview for : LG_RU-20LA61_LCD_TV_Service_Manual.zip part of LG RU-20LA61 LCD TV Service Manual LG LCD LG_RU-20LA61_LCD_TV_Service_Manual.zip
Back to : LG_RU-20LA61_LCD_TV_Servi | Home
website:http://biz.LGservice.com
e-mail:http://www.LGEservice.com/techsup.html
LCD TV
SERVICE MANUAL
CHASSIS : ML-012B
MODEL : RU-20LA61
CAUTION
BEFORE SERVICING THE CHASSIS,
READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
ST
MONO SAP DPM
STEREO
If you need more information on Computer and Electronic Repair, please visit these
websites to improve yourself.
http://www.fastrepairguide.com
http://www.protech2u.com
http://www.plasma-television-repair.com
http://www.lcd-television-repair.com
Happy Repairing!!
Highly Recommended Repair Ebook:
If you're a LCD Monitor repairer, then this is the best guide for you.
Why? Because, the author revealed all his LCD Monitor Repairing
secrets for you. I think, with just few Repair tips you learned from
this guide you will get back your investment!
Click Here to read more.
This eBook will show you how to test the electronic component
correctly and accurately. Some of you may say that I don't
need this eBook because it is too simple! Do you know that, in fact
there is lots of testing electronic components secrets I have learned
from this guide? Do you know how to test a`TRIAC' correctly and
accurately? If you answer no then I guess you have to get this
EBook. Click Here to read more.
Are you tired of searching the service manuals to look for the value
of a burnt resistor? If the answer is YES, then this eBook is a `must
have' guide for you. You can save a lot of time and be able to repair
customer's Electronic equipment with burnt resistors in it.
Click here to read more.
SAFETY PRECAUTIONS
IMPORTANT SAFETY NOTICE
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in
the Schematic Diagram and Replacement Parts List.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to
prevent X-RADIATION, Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.
General Guidance Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source,
An lsolation Transformer should always be used during connect an electrical jumper across the two AC plug prongs.
the servicing of a receiver whose chassis is not isolated from Place the AC switch in the on positioin, connect one lead of
the AC power line. Use a transformer of adequate power rating ohm-meter to the AC plug prongs tied together and touch other
as this protects the technician from accidents resulting in ohm-meter lead in turn to each exposed metallic parts such as
personal injury from electrical shocks. antenna terminals, phone jacks, etc.
If the exposed metallic part has a return path to the chassis, the
It will also protect the receiver and it's components from being measured resistance should be between 1M and 5.2M.
damaged by accidental shorts of the circuitary that may be When the exposed metal has no return path to the chassis the
inadvertently introduced during the service operation. reading must be infinite.
An other abnormality exists that must be corrected before the
If any fuse (or Fusible Resistor) in this TV receiver is blown, receiver is returned to the customer.
replace it with the specified.
Leakage Current Hot Check (See below Figure)
When replacing a high wattage resistor (Oxide Metal Film Plug the AC cord directly into the AC outlet.
Resistor, over 1W), keep the resistor 10mm away from PCB. Do not use a line Isolation Transformer during this check.
Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
Keep wires away from high voltage or high temperature parts. between a known good earth ground (Water Pipe, Conduit, etc.)
and the exposed metallic parts.
Due to high vacuum and large surface area of picture tube, Measure the AC voltage across the resistor using AC
extreme care should be used in handling the Picture Tube. voltmeter with 1000 ohms/volt or more sensitivity.
Do not lift the Picture tube by it's Neck. Reverse plug the AC cord into the AC outlet and repeat AC
voltage measurements for each esposed metallic part. Any
Before returning the receiver to the customer, voltage measured must not exceed 0.75 volt RMS which is
corresponds to 0.5mA.
always perform an AC leakage current check on the exposed In case any measurement is out of the limits sepcified, there is
metallic parts of the cabinet, such as antennas, terminals, etc., possibility of shock hazard and the set must be checked and
to be sure the set is safe to operate without damage of repaired before it is returned to the customer.
electrical shock.
Leakage Current Hot Check circuit
AC Volt-meter
Good Earth Ground
such as WATER PIPE,
To Instrument's CONDUIT etc.
0.15uF
exposed
METALLIC PARTS
1.5 Kohm/10W
- 2 -
TABLE OF CONTENTS
SPECIFICATIONS.................................................................4
DESCRIPTION OF CONTROLS ...........................................5
ADJUSTMENT INSTRUCTIONS ..........................................9
PRINTED CIRCUIT BOARD ...............................................10
BLOCK DIAGRAM...............................................................13
EXPLODED VIEW...............................................................14
EXPLODED VIEW PARTS LIST .........................................15
REPLACEMENT PARTS LIST ............................................16
SCHEMATIC DIAGRAM..........................................................
- 3 -
SPECIFICATIONS
Model RU-15LA61 RU-20LA61
Horizontal size (Inches) 18.3 22.8
Height (Inches) 14.8 18.3
Thickness (Inches) 6.7 8
Weight (pounds) 13.9 21.6
Power requirements DC 12V/4.5A DC 15V/4.5A
Television system NTSC
Television channels VHF : 2 ~ 13, UHF : 14 ~ 69
Cable : 01 ~ 125
Television Screen LCD Panel
External antenna impedance 75
Power consumption 50 W 70 W
Audio output 3W+3W 5W+5W
Adapter (DC power) In : AC 100-240V ~ 1.5A-0.6A
In: AC 100-240V ~ 1.5A-0.6A In: AC 100-240V ~ 1.6A-0.7A
50/60Hz 50/60Hz, 115~180VA
50/60Hz
Out : DC 12V, 5A
Out: DC 12V, 5A Out: DC 15V, 4.5A
For use only with Model No. For use only with Model No.
* CAUTION : For use only with Model No. SAD6012SE AC Adapter, manufactured by H &
E co., Ltd.
SAD6012SE AC Adapter, man- SAD7015SE AC Adapter,
ufactured by H & E co., Ltd. manufactured by H & E co., Ltd.
Power supply cordset : Standard North America three wire earth-grounding with
flexible cord SJT type or higher type.
* CAUTION : If replacement becomes necessary, replace with an exact duplicate.
Contact any LG authorized service center.
- 4 -
DESCRIPTION OF CONTROLS
Front of the TV
ST
MONO SAP DPM
STEREO
ST
MONO SAP DPM
STEREO
Stereo Indicator
SAP Indicator
Mono Indicator DPM Indicator
(RU-15LA61 Only)
Power/Standby indicator
Illuminates red in standby mode, Illuminates
green when the TV is turned on.
Remote Control Sensor
- 5 -
DESCRIPTION OF CONTROLS
Back of the TV
* Kensington
Security System
Connector
RU-15LA61 PC Input PC sound Input DC 12V Input
ANT IN Y PB PR L R PC INPUT PC VIDEO (MONO) L AUDIO R DC 12V
+75 SOUND
COMPONENT(480i/480p/720p/1080i) AUDIO VIDEO IN
DVD/DTV IN
Antenna Input DVD/DTV IN Audio/Video Input
(Component (480i/480p/720p/1080i),
RU-20LA61 AUDIO) Input DC 15V Input
DC IN (15V)
ANT IN Y PB PR L R VIDEO (MONO) L AUDIO R
+75
COMPONENT(480i/480p/720p/1080i) AUDIO VIDEO IN
DVD/DTV IN
- This manual mainly explains the features for the RU-15LA61
- 6 -
DESCRIPTION OF CONTROLS
Side of the TV
Side Control Panel
ch Channel Buttons
ST
MONO SAP DPM
STEREO
vol Volume Buttons
enter Enter Button
Side Connection Panel
menu Menu Button
tv
TV