Text preview for : KB0000119.PDF part of Minolta KB0000119 Minolta Copiers Di620 KB0000119.PDF



Back to : KB0000119.PDF | Home

Knowledge Data Base ( KDB No.: KB0000119 / Status: Close )

Model:
Di620
Problem Machine:
Di620
Title:
Malfunction of panel display in the version upgrade of MSC
Symptom:
Control / Wrong Indication
Symptom Explanation:
When the version of MSC was being upgraded from 10G0-44-00 to
10G0-53-00,
the malfunction of the panel display occurred.

Temporary Measure:

CounterMeasure:
Upgrade the version of Message ROM
Cause:
There is a combinational problem between the version of MSC and
the one of Message.


If the firmware version of MSC is upgraded in the machine before speed-up
modification (G version), note that there are some ROMs which have to be
replaced as a set. If the combination is incorrect, the malfunction of panel
display occurs and the machine doesn't function correctly.


The following two ROMs have to be replaced at the same time as a set.
* Message : 1155-80G0-07-00
* IR : 1155-23G0-28-00

1155-10G0-55-00>
The following ROM has to be replaced at the same time as a set.
* 1155-80G0-09-00
Problem Rank:
C Check
Parts Modification Notice:
Ref.No.:

SW/FW Distribution:


Category:
PPC\Digital-B/W
Expand Machine:
Di520(Main Unit)
Di620(Main Unit)
Cause Area:
Firmware
Original Report:

Information Date:
05.04.2000
Edit Date:
05.04.2000
Created by:
koji tokuyama/minolta