Text preview for : change110.pdf part of Funai 11AK19 Schema Elettrico e Note di servizio



Back to : TV AK19.part01.rar | Home

ELEKTRONK A..

TECHNICAL CHANGE BULLETIN

CHANGE NO: 110 REF NO : DATE : 12.02.2002

AFFECTED MODELS:. AK19 28''Models with VCL crt START DATE : 12.02.2002 REASONS OF CHANGE: In order to prevent anode voltage peaks during start-up.

NO 1 2 3 4 5 6 7 NO 1 2 3 4 5

PCB CODE

VESTEL CODE
30000180

OUT COMPONENT NAME
CAP MKP 9.1NF 2000V %3.5

POSITION NUMBER
C626

QUANTITY
1

PCB CODE

VESTEL CODE
30007100

IN COMPONENT NAME
CAP MKP 10NF 1600V %3,5

POSITION NUMBER
C626

QUANTITY
1

CUSTOMER SUPPORT ENGINEER GÜRSEL AYKOL

QUALITY MANAGER ALI TUNC CAN

Form Rev.No:00