Text preview for : change109.pdf part of Funai 11AK28 Schema Elettrico ( Manual Service )
Back to : TV AK28.rar | Home
PRODUCT CONTENT CHANGE BULLETIN
ELEKTRONK A. ORGANZE SANAY BÖL.MANSA/ TURKEY
REF NO
UMB - xx
CHANGE REQUEST
EXPLANATION:
THE BREAKDOWN PROBLEM OF THE IC TDA 6111Q ON THE POSITIONS IC901, IC902 AND IC903 ON THE 11TP28 BASE BOARD. 11TP28 VER E:5 PCB SHOULD BE REPLACED WITH 11TP28-7 IMMEDIATELY.
APPLICATION REQUEST DATE
AFFECTED PRODUCTS
* IMMEDIATELY
* RUNNING CHANGE
ADD. LIST
COMPONENTS OUT
No 1 2 3 4 5 6 7 8 9 10 No 1 2 3 4 5 6 7 8 9 10 PCB Code / Pic. No VESTEL Code Description Position Amount
11 TP 28 VER-5 11 TP 28 VER-5 11 TP 28 VER-5 11 TP 28 VER-5 11 TP 28 VER-5 11 TP 28 VER-5 11 TP 28 VER-5
30016571 30000433 30000428 30000580 30001994 30002583 30000295 30002876
PCB 11TP28 (VER:E5) CAP CER 1NF 1KV M B SPARK GAP 300V RES CF 1/4W 22R J FIXED COIL 22UH J AXIAL KISA DEVRE TEL 0.6MM CAP CER 100NF 50V Z F CABLE ASSY 1/25 AK19 EMC
C 937 SP 901, SP XX R 940 J 921 J 920 C 940
1 1 2 1 1 1 1 1
COMPONENTS IN
PCB Code / Pic. No VESTEL Code Description Position Amount
11 TP 28-7 11 TP 28-7 11 TP 28-7
30017573 30000428 30001994 30002583
PCB 11TP28-7 SPARK GAP 300V FIXED COIL 22UH J AXIAL KISA DEVRE TEL 0.6MM
SP 901, SP 903, SP 904 SP 905, SP 906, SP 907 L 921 J 915, J 916
1 6 1 2
COMPONENT IN
COMPONENT IN
ALTERNATIVES FOR COMPONENTS IN
ALTERNATIVE
EXIST NOT EXIST
DIFFERENCE COMP.
ADD. LIST
RESPONSIBLE ENGINEER
NAME SURNAME / SIGNATURE DATE/TIME
App. Eng. Manager Approval
SIGNATURE
FINAL NOTES
Form Rev. No: 01
Form No: 04.UMB..01