Text preview for : BO4561-TE.pdf part of MAKITA BO4561-TE MAKITA BO4561-TE.pdf
Back to : BO4561-TE.pdf | Home
T ECHNICAL INFORMATION
BO4561
New Tool
For Models
Description Finishing Sander
CONCEPTION AND MAIN APPLICATIONS
137 mm
(5-3/8")
Model BO4563 is sister version of the existing
Model BO4561 and intended for sanding louvers.
Its brief benefits are;
*Convenient for sanding narrow louvers
10 -15/
(3
0 16
by aquare and thinner plate 8")
m ")
(7-3/
m
m
*With functin of self-dust-collecting 187 m
*The face of pad is velcro type
to make replacing abrasive paper easy.
Specifications
Voltage(V) Current(A) Cycle(Hz) Continuous Rating(W) Max. Output(W)
Input Output
220 0.8 50/60 160 55 70
230 0.8 50/60 160 55 70
Orbits per minute 14,000 0/min
Dimension of pad 100mm(3-15/16")X164mm(6-1/2")
Net weight 1.0kg(2.2lbs)
Cord length 2m(6.6ft)
Featured and benifits
1. Double insulated
2. See the sheet attached for more information.
Thickness of pad without abrasive paper Housing shaped ergonomically
: 4.5mm(3/16") Easy palm-gripping makes
As it is about 6.5 mm thick(1/4") if attaching operation comfortable.
#60 Paper to both upper/lower parts,
suitable for abrasionin narrow space.
Dust Bag
Work area can be kept clean by
function of self-dust-collecting.
Velcro type for easy
changing Paper
Repair
When dismantling Housing, remove in advance Base complete, Fan guide, and Fan 63 in this order.
Circuit diagram
(1) Where Noise suppressor is used
Switch
Insulated connector
1 2
Black
Power supply cord
Noise suppressor
1 1 Field
Terminal
board
(2) Where Noise suppressor is not used
Switch
1 2
Power supply cord
1 1
Field
Terminal
board
Wiring diagram
Store Lead wire of Power supply cord into Lead holder.
( In case using Noise suppressor, place Lead wire of Noise
suppressor under Lead wire of Power supply cord)
Noise suppressor Pass Lead wire connecting with Brush holder
through here as shown in the Figure.
Pin
Pass Lead wires in Field and Noise
suppressor between Pin and Rib.
Rib
Fig. 1
Housing Housing
Switch Switch Lead wire
Lead wire
Fig. 4
Insulated Insulated
connector Place Lead wire lower than the
connector meeting face of Housing.
Fig. 2 Fig. 3
When you use Noise suppressor, place Insulated connector under Switch
on its side as shown in Fig. 3 to prevent it from interference with Switch