Text preview for : acc-148.pdf part of CANON acc-148 CANON Copiers GP 405 ServBull ServBullGP405 acc-148.pdf



Back to : acc-148.pdf | Home

Service Bulletin COPIER


Issued by Canon Europa N.V.




Model : Finisher D1 No.: Acc-148 Rev. 1
(FF-T01-W-000051-02)
DATE: 10.08.99



Location : SORTING GUIDE ASSEMBLY

Subject : PREVENTING STATIONARY JAMS (AROUND SORTING GUIDE)

Reason : Paper can hit the ribs in the sorting guide assembly to jam, and the problem can be corrected by
providing the measures shown herein during servicing work.

Details :
Depending on the type (degree of body) and how it is moved, paper can hit the ribs in the sorting
guide assembly to jam (stationary) in front of the sorting guide.


The absence of a gap between the ribs in the sorting guide assembly and passing paper hinders the
paper from moving properly, resulting in a stationary jam in front of the sorting guide.


A spacer is attached to the ribs in the sorting guide to create a clearance between the ribs and passing
paper, thereby ensuring smooth passage of paper.

Servicing : < Making Checks and Providing Measures >
1. If the delivery outlet tray is in the way,
change its location.




Fig. 1




-1/3-
Acc-148 Rev. 1


2. While holding up the swing guide, check Clearance: 0.5 mm or more
the gap between the sorting guide assembly
and the ribs. If the gap is not as indicated,
perform the following steps:




Fig. 2

3. Remove the four screws, and detach the stacking
wall (upper) of the Finisher-D1.




Screws


Fig. 3


4. Remove the processing tray unit. (See pp. 3-13 through
-14 in the Service Manual; FY8-13FF-000.) Connector
1) Remove the screw, and detach the sorting tray stopper. cover
2) Move up the sorting tray to its upper limit by hand. (See
the descriptions on the ascent of the sorting tray.)
3) Remove the four screws, and detach the stacking wall
Screw
(lower).
4) Remove the screw, and detach the connector cover.
(See Figure 4.)


Fig. 4


5) Remove the seven connectors, and free the harness
from the cord clamp. Harness
Connector




Fig. 5
-2/3-
Acc-148 Rev. 1
Processing tray unit
Screw Screw
6) Remove the four fixing screws, and detach the
processing tray unit.




Screw Screw
Fig. 6

5. Attach the 0.25-mm spacer to the sorting guide
assembly so that the ribs will lower.
Note: If one is not enough, attach another
spacer over it.



Attach a 0.25-mm
spacer so as to
lower the ribs.


Fig. 7

6. Check to make sure that the standard is satisfied.
Standard:
2.8 mm or more




Fig. 8

7. Mount the processing tray unit.
8. Mount the stacking walls (upper, lower).
9. Mount the sorting tray stopper.



Affected machines:
NLF00229 and later ULF00316 and later


-3/3-