1. FUNCTION OF SWITCHES AND OTHER PARTS ON
PWBs
1-1. PWB Location




PWB-S1




4004S002AC



1-2. PWB-S1 (Tech. Rep. Setting Switches Board)




4002S002AB




Symbol Name Description
Resets a paper misfeed, malfunction, and
INI Initialize Point
erratic display.
Clears data of various kinds stored in mem-
MEMORY Memory Clear Test Point
ory.
COM COM Test Point Ground used for memory clear.
Resets the following malfunction displays:
Exposure Lamp system (C04XX), Fusing
TROUBLE Trouble Reset Switch system (C05XX), Scanner system (C06XX),
ROM contents failure detected upon start
(C3FFF)
SERVICE Not used


S-1
FrameMaker Ver5.5E(PC) 8020/8031 SWITCHES ON PWBs/TECH. REP. SETTINGS
02.08.19




(1) Initialize Procedure
1. Turn OFF the Power Switch.
2. With the circuit across pins of PJ2 closed, turn ON the Power Switch.
3. In about 5 sec., open the PJ2 circuit.
4. Check that the message "Initialize Completed" is displayed on the Touch Panel and
then touch "END."

(2) Memory Clear Procedure
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and TP3 closed, turn ON the Power Switch.
3. In about 5 sec., open the circuit across TP1 and TP3.
4. Check that the message "Memory Clear Completed" is displayed on the Touch Panel
and then touch "END."
5. The following types of data are cleared.