Text preview for : AMI-516DP & 517DP.pdf part of Daewoo AMI-516DP & 517DP Daewoo AMI AMI-516DP & 517DP AMI-516DP & 517DP.pdf
Back to : AMI-516DP & 517DP.pdf | Home
Service Manual
MINI COMPONENT SYSTEM
Model : AMI-516DP / 516DPR
AMI-517DP / 517DPR
DAEWOO ELECTRONICS CO., LTD.
TABLE OF CONTENTS
SAFETY PRECAUTIONS ................................................................................................. 2
ADJUSTMENTS ............................................................................................................. 4
EXPLODED VIEW AND PARTS LIST ................................................................................. 7
AMI- 516DP ....................................................................................................................................... 7
AMI- 517DP ....................................................................................................................................... 9
WIRING DIAGRAM ...................................................................................................... 13
BLOCK DIAGRAM ....................................................................................................... 16
SCHEMATIC DIAGRAM ................................................................................................ 18
POWER / AMP .................................................................................................................................... 18
CD .................................................................................................................................................... 20
TUNER................................................................................................................................................ 21
TAPE .................................................................................................................................................. 24
CONTROL.......................................................................................................................................... 25
PCB PATTERN LAYOUT.................................................................................................. 28
ELECTRICAL PARTS LIST ................................................................................................ 33
1
SAFETY PRECAUTIONS
WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE laundry tub, in a wet basement, or near a swimming pool,
THIS APPLIANCE TO RAIN OR MOISTURE. and the like.
2. Carts and Stands - The appliance
CAUTION PORTABLE CART
should be used only with a cart or
RISK OF ELECTRIC SHOCKS stand that is recommended by th
DO NOT OPEN manufacturer.
3. An appliance and cart combination
CAUTION :TO REDUCE THE RISK IF ELECTRIC SHOCK, DO NOT should be moved with care. Quick
REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS stops, excessive force, and uneven
INSIDE. surfaces may cause the appliance
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. and cart combination to overturn.
Figure 2 4. Wall or Ceiling Mounting - The appli-
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE
PRESENCE OF UNINSULTED "DANGEROUS VOLTAGE" ance should be mounted to a wall or
WITHIN THE PRODUCT'S ENCLOSURE THAT MAY BE ceiling only as recommended by the manufacturer.
SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF 5. Ventilation - The appliance should be situated so that its
ELECTRIC SHOCK TO PERSONS. location or position does not interfere with its proper
ventilation. For example, the appliance should not be situated
THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE
PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE on a bed, sofa, rug, or similar surface that may block the
(SERVICING) INSTRUCTIONS IN THE LITERATURE ventilation openings; or, placed in a built-in installation, such
ACCOMPANYING THE APPLIANCE. as a bookcase or cabinet that may impede the flow of air
through the ventilation openings.
CAUTION 6. Heat - The appliance should be situated away from heat
TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS POLARIZED AC
sources such as radiators, heat registers, stoves, or other
PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET
UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE appliances (including amplifiers) that produce heat.
EXPOSURE. 7. Power Sources - The appliance should be connected to a
power supply only of the type described in the operating
LASER SAFETY instructions or as marked on the appliance.
THIS UNIT EMPLOYS A LASER. ONLY QUALIFIED SERVICE PERSONNEL
8. Grounding or Polarization - The precautions that should be
SHOULD REMOVE THE COVER OR ATTEMPT TO SERVICE THIS DEVICE
DUE TO POSSIBLE EYE INJURY. taken so that the grounding or polarization means of an
appliance is not defeated.
CAUTION : USE OF ANY CONTROLS, ADJUSTMENTS, OR PROCEDURES 9. Power - Cord Protection - Power-supply cords should be
OTHER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS routed so that they are not likely to be walked on or pinched
RADIATION EXPOSURE. by items placed upon or against them, paying particular
attention to cords at plugs, convenience receptacles, and the
CAUTION : TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF
PLUG TO WIDE SLOT, FULLY INSERT. point where they exit from the appliance.
10.Protective Attachment Plug - The appliance is equipped with
ATTENTION : POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE an attachment plug having overload protection. This is a
LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPON- safety feature. See Instruction Manual for replacement or
DANTE DE LA PRISE ET POUSSER JUSQU'AU FOND. resetting of protective device. If replacement of the plug is
required, be sure the service technician has used a
replacement plug specified by the manufacturer that has the
Important Safety Instructions same overload protection as the original plug.
- All the safety and operating instructions should be read before 11.Cleaning - The appliance should be cleaned only as
the appliance is operated. recommended by the manufacturer.
- The safety and operating instructions should be retained for 12.Power Lines - An outdoor antenna should be located away
future reference. from power lines.
- All warnings on the appliance and in the operating instructions
should be adhered to.
- All operating and use instructions should be followed.
1. Water and Moisture - The appliance should not be used near
water - for example, near a bathtub, washbowl, kitchen sink,
2
SAFETY PRECAUTIONS
13.Outdoor Antenna Grounding - If an outside antenna is 15.Object and Liquid Entry - Care should be taken so that objects
connected to the receiver be sure the antenna system is do not fall and liquids are not spilled into the enclosure through
grounded so as to provide some protection against voltage openings.
surges and built-up static charges. Article 810 of the National 16.Damage Requiring Service - The appliance should be
Electrical Code, ANSI/NFPA 70, provides information with serviced by qualified service personnel when:
regard to proper grounding of the mast and supporting a) The power-supply cord or the plug has been damaged; or
structure, grounding of the lead-in wire to an antenna-dis b) Objects have fallen, or liquid has been spilled into the
charge unit, size of grounding conductors,location of antenna- appliance; or
discharge unit, connection to grounding electrodes and c) The appliance has been exposed to rain; or
requirements for the grounding electrode. See Figure 1. d) The appliance does not appear to operate normally or
exhibits a marked change in performance; or
e) The appliance has been dropped, or the enclosure
EXAMPLE OF ANTENNA
GROUNDING ANTENNA LEAD
damaged.
IN WIRE
17.Servicing - The user should not attempt to service the
appliance beyond that described in the operating instructions.
GROUND CLAMP All other servicing should be referred to qualified service
ANTENNA DISCHARGE UNIT
(NEC SECTION 810-20) personnel.
GROUNDING CONDUCTORS
ELECTRIC (NEC SECTION 810-21)
SERVICE
EQUIPMENT
GROUND CLAMPS
POWER SERVICE GROUNDING
ELECTRODE SYSTEM
NEC - NATIONAL ELECTRICAL CODE (NEC ART 250 PART H)
14.Non-use Periods - The power cord of the appliance should be
unplugged from the outlet when left unused for a long period
of time.
3
ADJUSTMENTS
1. TUNER SECTION FM RF SSG FM Antenna
Terminal(75 ohm)
TEST EQUIPMENT
75 ohm Coaxal
1. Signal Generator with a frequency range of FM broadcast.
SET
2. Oscilloscope with a side amplifier of approximately 100 KHz.
Carrier Frequency : 98MHz
3. FM 75/50 dummy antenna. Output Level : 26dBuV
Modulation:Audio 1kHZ, 75kHz Deviation
4. VTVM
FM ALIGNMENT
1. Turn on the FM signal generator and the VTVM allowing 15 minutes warming-up period.
2. Connect the VTVM across the headphone jack or speaker terminal.
3. Set signal generator frequency as listed in ALIGNMENT CHART and maintain a sufficient output level to provide an
indication on VTVM.
NOTE
1. Use a screwdriver with plastic or ceramic grip for all adjustments.
2. Standard test frequency 1 KHz and deviation 75 KHz for FM.
- FM RF, IF ALIGNMENT CHART -
Step Item Input Circuit Setup Output Circuit Setup Tuner Setting Adjust Point Adjustment
Connect stereo signal FM98MHz75KHz
FM IF Connect DC voltme-
1 generator to FM ANT L203 Adjust forDC 0V