Text preview for : GX-707.PDF part of Yamaha GX-707 Yamaha GX GX-707 GX-707.PDF
Back to : GX-707.PDF | Home
GX-707/GX-707VCD
MINI COMPONENT SYSTEM
GX-707
GX-707VCD
SERVICE MANUAL
GX-707/VCD
GX-707 is composed of GX-707 (main unit) and NX-P707 (speakers).
GX-707VCD is composed of GX-707VCD (main unit) and NX-P707 (speakers).
NX-P707 is composed of NX-GX505, NX-C707 and NX-E707.
The NX-C707 and NX-E707 loudspeakers are not field serviceable and must be replaced as complete units.
IMPORTANT NOTICE
This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are
already known and understood by the users, and have therefore not been restated.
WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in
personal injury, destruction of expensive components, and failure of the product to perform as specified.
For these reasons, we advise all YAMAHA product owners that any service required should be performed
by an authorized YAMAHA Retailer or the appointed service representative.
IMPORTANT: The presentation or sale of this manual to any individual or firm does not constitute authorization, certifica-
tion or recognition of any applicable technical capabilities, or establish a principle-agent relationship
of any form.
The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and
service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore,
inevitable and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to
exist, please contact the distributor's Service Division.
WARNING: Static discharges can destroy expensive components. Discharge any static electricity your body may have
accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this
buss).
IMPORTANT: Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the
unit.
s CONTENTS
TO SERVICE PERSONNEL ................................... 1--2 ALL FUNCTION TEST MODE .................................... 18
GX-707 PANELS ..................................................... 3--4 CD ERROR MESSAGES ............................................ 18
GX-707VCD PANELS ................................................... 5 CD STANDARD OPERATION CHART .............. 19--20
SPECIFICATIONS ......................................................... 6 ADJUSTMENTS .................................................. 21--23
INTERNAL VIEW .......................................................... 7 IC DATA .............................................................. 24--30
DISASSEMBLY PROCEDURES .......................... 8--12 DISPLAY DATA .................................................. 31--32
VOLUME RANGE ....................................................... 13 BLOCK DIAGRAM .............................................. 33--37
SYSTEM CONTROL CHECK ..................................... 13 PRINTED CIRCUIT BOARD ............................... 38--62
TEST MODE ................................................................ 14 PIN CONNECTION DIAGRAM ................................... 63
SYSTEM TEST MODE ................................................ 14 SCHEMATIC DIAGRAM ..................................... 64--72
RECEIVER TEST MODE .................................... 15--16 PARTS LIST ...................................................... 73--108
TAPE TEST MODE ..................................................... 16 GX-707 REMOTE CONTROL TRANSMITTER ........ 109
CD TEST MODE ......................................................... 17 GX-707VCD REMOTE CONTROL TRANSMITTER .... 110
100713
GX-707/GX-707VCD
s TO SERVICE PERSONNEL
1. Critical Components Information. AC LEAKAGE
Components having special characteristics are marked Z WALL EQUIPMENT TESTER OR
and must be replaced with parts having specifications equal OUTLET UNDER TEST EQUIVALENT
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only).
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits. INSULATING
TABLE
GX-707/VCD
q Meter impedance should be equivalent to 1500 ohm shunted q Leakage current must not exceed 0.5mA.
by 0.15