Text preview for : 2LW-008.pdf part of Kyocera 2LW-008 Kyocera Printer FS-3040-3140MFP SERVICEBULLETIN 2LW-008.pdf
Back to : 2LW-008.pdf | Home
Service Bulletin
SB Number: SB 2LW-008 Creation Date: 22/06/2011
Subject: Switching mistake of the envelope mode
Model: FS-3040MFP/3140MFP
Phenomenon The switching button mismatch may occur when setting the fuser pressure to envelope mode.
Solution When the above mentioned phenomenon occurs, please replace the Button fuser and
Button fuser B with the latest type.
Fuser unit
Button fuser/Button fuser B specifications.
Cutting:120
Rib height has
degrees
been reduced from
Button fuser B Button fuser 6mm to 5.5mm.
Height:
3.3mm.
Old condition New condition
0.9mm.
Thickness increased
by 0.6mm
Parts
No. Old Parts New Parts Description Q'TY Interchange-
No. No. ability
Old New Old New
1 302J025051 302J025052 BUTTON FUSER 1 1 X X
2J025051 2J025052
2 302J025240 302J025241 BUTTON FUSER B 1 1 X X
2J025240 2J025241
Classification Entire stock rework X In-field modification by case No modification necessary
In-field modification at next visit
Field measure When the above mentioned phenomenon occurs, please replace the Button fuser and
Button fuser B with the latest type.
Serial numbers of affected machines
Type Serial number
FS-3040MFP/3140MFP November 2010 production.
The above mentioned changes have been applied to machines produced after the above mentioned production date.
KMIS Service Department, Kyocera Mita Europe Page of A378 / SB 2LW-008