Text preview for : Mainte.pdf part of Minolta Mainte Minolta Copiers Di250 orig_man Maintenance Mainte.pdf



Back to : Mainte.pdf | Home

FrameMaker Ver.5.5(PC) Di250 MAINTENANCE SCHEDULE
99.1. 7




Di250 MAINTENANCE SCHEDULE

This Maintenance Schedule is intended to be used as reference information for establishing effective field service activi-
ties. To keep the copiers in as optimum a condition as possible, it is recommended that the maintenance jobs described in
this schedule be carried out.


It should be noted, however, that frequency of maintenance jobs determined by the number of copies is simply a guide-
line. Therefore, service management personnel can revise or amend this schedule by taking into account their own indi-
vidual field experiences. We feel that this will ensure more effective copier maintenance for your customers.


* This time interval (the number of copies produced) at which each component is cleaned or replaced is determined
based on the average service life of the component. More or less frequent cleaning or replacement will be necessary
depending on the actual image quality and paper passage performance.


NOTE: All information in this Maintenance Schedule is subject to change without prior notice.
C: Cleaning R: Replacement Unit: 1000 Copies
FrameMaker Ver.5.5(PC) Di250 MAINTENANCE SCHEDULE
99.1. 7




s PAPER TAKE-UP/TRANSPORT SECTION K=1,000 copies
Maintenance Cycle (K) Reference
PM Parts Parts No. QTY
Clean Replace Page
Paper Take-Up Roll - 120 1164-3001-01 1 D-10
Paper Dust Remover 60 120 1165-0756-01 1 D-10
Side Cover 60 - - - D-11
s OPTICAL SECTION
Maintenance Cycle (K) Reference
PM Parts Parts No. QTY
Clean Replace Page
Mirrors/Lens 120 - - - D-16
Scanner Rails/Bushings 60 - - - D-15
Original Glass 60 - - 1 D-16
s IMAGE TRANSFER SECTION
Maintenance Cycle (K) Reference
PM Parts Parts No. QTY
Clean Replace Page
Image Transfer Roller - 150 1164-0335-01 1 D-23
Pre-Image Transfer Guide Plate 60 - - 1 D-24
s FUSING SECTION K=1,000 copies
Maintenance Cycle (K) Reference
PM Parts Parts No. QTY
Clean Replace Page
Fusing Unit - 300 - 1 D-26
FrameMaker Ver.5.5(PC) Di250 MAINTENANCE SCHEDULE
99.1. 7




Copyright
1999 MINOLTA Co., Ltd.
Printed in Japan


Use of this manual should
be strictly supervised to
avoid disclosure of
confidential information.




MINOLTA Co., Ltd. 1170-7993-11 99022400
17196