Text preview for : NS-P210.PDF part of Yamaha NS-P210 Yamaha NS NS-P210 NS-P210.PDF
Back to : NS-P210.PDF | Home
NS-P210
HOME THEATER SPEAKER SYSTEM
NS-P210 SERVICE MANUAL
NS-P210 is composed of NX-210P, NX-C210 and SW-P201.
The NX-210P and NX-C210 loudspeakers are not field serviceable and must be replaced as complete units.
q SW-P201
q NX-210P x 4
q NX-C210
IMPORTANT NOTICE
This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel.
It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already known and understood by the users,
and have therefore not been restated.
WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive
components, and failure of the product to perform as specified. For these reasons, we advise all YAMAHA product owners that any service
required should be performed by an authorized YAMAHA Retailer or the appointed service representative.
IMPORTANT: The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or recognition of any applicable
technical capabilities, or establish a principle-agent relationship of any form.
The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are
continually striving to improve YAMAHA products. Modifications are, therefore, inevitable and specifications are subject to change without notice or obligation to
retrofit. Should any discrepancy appear to exist, please contact the distributor's Service Division.
WARNING: Static discharges can destroy expensive components. Discharge any static electricity your body may have accumulated by grounding yourself to the
ground buss in the unit (heavy gauge black wires connect to this buss).
IMPORTANT: Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit.
s CONTENTS
TO SERVICE PERSONNEL . . . . . . . . . . . . . . . . . . . . 1 SW-P201 BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . 5
SW-P201 REAR PANELS . . . . . . . . . . . . . . . . . . . 1--2 SW-P201 PRINTED CIRCUIT BOARD . . . . . . . . . 6--7
NS-P210
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 SW-P201 SCHEMATIC DIAGRAM . . . . . . . . . . . . . . . 8
SW-P201 DISASSEMBLY PROCEDURES . . . . . . . . . 4 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9--14
100709
NS-P210
s TO SERVICE PERSONNEL
1. Critical Components Information. AC LEAKAGE
WALL EQUIPMENT TESTER OR
Components having special characteristics are marked Z OUTLET UNDER TEST EQUIVALENT
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only).
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated INSULATING
from supply circuits. TABLE
q Meter impedance should be equivalent to 1500 ohm shunted q Leakage current must not exceed 0.5mA.
by 0.15