Text preview for : ADJ6XX2.PDF part of HP deskjet 6xx hp deskjet 6xx adjustments
Back to : hp deskjet 6xx.rar | Home
Adjustments
HP DeskJet 6xx Printers
Set Up and Calibrate the PPS Measure Tool and Readout/Controller
Note The following calibration procedure verifies the PPS Measure Tool and Readout/Controller are operating properly. 1. Set the dip switches on the back of the Readout/Controller as shown below.
CHANNEL
Switches
2168602
2. Plug the PPS Measure Too into CHANNEL A on the back of the Readout/Controller. 3. Plug in the AC power cord. Allow the instrument to warm up for at least 10 minutes.
Adjustments - Set Up and Calibrate the PPS Measure Tool and Readout/Controller
1.
4. On the Readout/Controller, press the MENU button. The Readout/Controller will display the message PASSWORD PLEASE. 5. Enter the password (press the , , and buttons). The Readout/Controller should display CAL SW DISABLED. 6. Press the CAL button. The Readout/Controller should display CAL SW ENABLED.
PRE-SET Light CAL Light
SP2
SP
SP
GO
ZER
CAL
PRE
PRE-SET Button CAL Button ZERO Button
MENU
1.2345
MENU Button
SEL
RST
2168601
7. Using the MENU button, step through and verify all of the Readout/Controller settings. The table below identifies the Readout/Controller settings. Use the following procedure to change a Readout/Controller settings: · Press the PRE-SET button () to position the cursor over the digit. · Press the and buttons on the Readout/Controller to increase and decrease the setting value. · Once the desired setting is obtained, press the MENU button to retain the new setting and sequence to the next setting in the table.
Adjustments - Set Up and Calibrate the PPS Measure Tool and Readout/Controller
2.
8. Continue to press the MENU button, sequencing through all of the Readout/Controller settings until the display reads DEPRESS MENU SWITCH TO RUN. Table 1. Readout/Controller Settings Selection
DECIMAL PT CH(A) PRE-SET # CH(A) CAL # CH(A) FS # CH(A) SP1 TO MONITOR SP1 TO BE SET SP1 SP2 TO MONITOR SP2 TO BE SET SP2 SP3 TO MONITOR SP3 TO BE SET SP3 SP4 TO MONITOR SP4 TO BE SET SP4 SET LOW HYS SET HIGH HYS
Setting
000.03 000.00 070.00 050.00 CH(A) LOW SETPOINT -001.00 CH(A) LOW SETPOINT 028.00 CH(A) HIGH SETPOINT 058.00 CH(A) HIGH SETPOINT 071.00 000.00 000.00
DEPRESS MENU SWITCH TO RUN
Adjustments - Set Up and Calibrate the PPS Measure Tool and Readout/Controller
3.
Adjustments - Set Up and Calibrate the PPS Measure Tool and Readout/Controller
4.