Text preview for : ssi.pdf part of Nokia 5110 Service Manual Gsm Telephone - File 17 - Part 1/3
Back to : gsm_NSE-1NX_©_.part1.rar | Home
PAMS Technical Documentation NSE1/3 Series Transceivers
Service Software Instructions
Original 03/98
NSE1/3 Service Software Instructions
PAMS Technical Documentation
CONTENTS
Service Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware requirements for Windows 3.1x . . . . . . . . . . . Hardware requirements for Windows 95 . . . . . . . . . . . . Software Environment of the Support Modules . . . . . . . . . Required Servicing Equipment . . . . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the Software on PC Hard Disk . . . . . . . . . . . . Common Properties of the User Interface . . . . . . . . . . . . . . . . . . Login Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Main Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Phone Identity Window . . . . . . . . . . . . . . . . . . . . . . . . . . . Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mouse Cursors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reserved Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Short Cut Function Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alt Hot Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ctrl Hot Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Shift Hot Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Key Strokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Help Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dialog boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Common Dialog boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Note Message Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Query Message Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Message Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Custom Dialog boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reporting Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5 5 5 6 7 7 8 9 9 10 13 13 14 14 14 15 15 15 16 16 17 17 17 17 17 18 18 20 20 20 20 21 21 22 22 23
Page 2
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
NS*1/3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Menu bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . New command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Open... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initialise... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Normal Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RX Calibration... command . . . . . . . . . . . . . . . . . . . . . . . . Tx Power... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tx I/Q... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Energy Management Calibration... command . . . . . . . . Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF Controls... command . . . . . . . . . . . . . . . . . . . . . . . . . . RSSI Reading... command . . . . . . . . . . . . . . . . . . . . . . . . Self Tests... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . ADC Readings... command . . . . . . . . . . . . . . . . . . . . . . . Audio... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internal Audio Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External Audio Loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Interface... command . . . . . . . . . . . . . . . . . . . . . . . . Call Simulation... command . . . . . . . . . . . . . . . . . . . . . . . Noise Sensitivity... command . . . . . . . . . . . . . . . . . . . . . . IR Test... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Profile... command . . . . . . . . . . . . . . . . . . . . . . . Start Up Selftests... command . . . . . . . . . . . . . . . . . . . . Set Factory Values... command . . . . . . . . . . . . . . . . . . . . Phone Identity... command . . . . . . . . . . . . . . . . . . . . . . . . Warranty State... command . . . . . . . . . . . . . . . . . . . . . . . Production Data Edit... command . . . . . . . . . . . . . . . . . . Flash Phone... command . . . . . . . . . . . . . . . . . . . . . . . . . Dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Settings... command . . . . . . . . . . . . . . . . . . . . . . . . . Short Code Memory... command . . . . . . . . . . . . . . . . . . . SCM & User Settings... command . . . . . . . . . . . . . . . . . . Set UI/DEV Default Values... command . . . . . . . . . . . . .
24 24 24 24 24 24 25 25 26 26 28 30 32 34 34 38 38 41 42 42 44 45 45 47 48 49 49 49 51 52 54 55 56 58 58 59 60 61
Original 03/98
Page 3
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Operators Settings... command . . . . . . . . . . . . . . . . . . . . Postprogrammable Memory... command . . . . . . . . . . . View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick/RF Info... command . . . . . . . . . . . . . . . . . . . . . . . . Phone Identity... command . . . . . . . . . . . . . . . . . . . . . . . . Appendix 1, Vocabulary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
62 63 64 64 65 67
Page 4
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Service Software
General
To run the After Sales SW, a parallel port software protection device (PKD1) has to be connected. TDF4 box must connected to PC for flashing purposes. The user can use WinTesla functions in modules for testing NSE1/3 mobile stations (MS). The test functions send test messages from PC to MS and receive results and show them in the PC display. The messages can be sent via M2BUS or FBUS. Note: if this software is to be run on laptops, the power saving feature MUST be switched off. Hardware requirements for Windows 3.1x The recommended minimum hardware standard to run Service Software is any computer which is 386 33 MHz or greater with at least 4 MB of memory and VGA type display (640 x 480). This assumes that only the WinTesla with After Sales Support Modules is active, i.e. other Windows packages are not running in the background. Hardware requirements for Windows 95 The recommended minimum hardware standard to run Service Software is any computer which has Pentium processor, memory 8 MB and meets HW requirements recommended by Microsoft.
Software Environment of the Support Modules
The Service Software user interface is intended for the following environments: Microsoft Windows 3.1x (enhanced mode) and Windows 95environment running in enhanced mode. Support for Microsoft NT may be added, if required. Detailed information about Windows and application usage can be found from the Microsoft Windows Version 3.1 Users Guide chapter one (Windows Basics) and chapter two (Application Basics). As an ordinary Windows application, the main idea in the user interface is that selections are made with menus, push buttons and shortcut keys. Selections can be done by using keyboard and/or mouse. There is always a status bar displayed at the bottom of the main window which contains information about current actions.
Original 03/98
Page 5
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Required Servicing Equipment
Computer: At least IBM 80386 or compatible with one unused serial port (COM1 or COM2) *), one parallel port (LPT1), hard disk recommended Operating System: DOS Version 3.2 or later If PCLStart in use: DOS 6.22 and IBM 80486 or compatible Display: Any 80character text display Service software version for 3.5" disk (product code: 0774080) Software protection key PKD1 (product code: 0750018) Service MBUS Cable DAU9P (product code: 0730109) Audio cable ADS1 (product code: 0730011) External Antenna Cable XRC1B (product code 0730128) Modular Tadapter (product code: 4626134)
*) Note:
A number of PC's of an older generation use the Intel, National Semiconductor, or United Microelectronics IC 8250 as the serial port UART. This is a comparatively inefficient circuit for current purposes and does not necessarily support the M2BUS adapter at 9600 baud. The newer UART's NS16450 and NS16550AF of National Semiconductor offer solutions for these problems.
Page 6
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Installation
Mechanical Connections
Caution: Make sure that you have switched off the PC and the printer before making connections. Caution: Do not connect the PKD1 key to the serial port. You may damage your PKD1 !
The software controls the phone via a separate adapter connected to the serial port of the PC, and to the telephone's M2BUS (DAU9P). Attach the dongle PKD1 to the parallel port 1 (25pin female Dconnector) of the PC. When connecting PKD1 to the parallel port, be sure that you insert the computer side of the PKD1 to the PC (male side). If you use a printer on parallel port 1, install the PKD1 between the PC and your printer cable. The PKD1 should not affect devices working with it. If some errors occur (errors in printing are possible) please try printing without the PKD1. If printing is OK without the PKD1 please contact your dealer. We will offer you a new PKD1 in exchange for your old one.
Original 03/98
Page 7
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Installing the Software on PC Hard Disk The program is delivered on a diskette and is copy protected with a dongle PKD1. It must be present in parallel port when using Service software. The program can also be installed on the hard disk, which is recommendable to obtain a maximum data access rate. Keep the original diskette safe to enable upgrading of the program ! If you plan to use PCL Start service software, you must install it before installing Service software, see PCL Start installation instructions. To install the new Service software program, follow the steps below: 1. 2. 3. insert the new Service software diskette into drive A: of your computer start Windows, and open File Manager log into drive a: start INSTALL.EXE and
type A: and press type C: and press
install Service software to drive C:
Page 8
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Common Properties of the User Interface
This chapter describes how the User Interface CLF must appear to the user. The User Interface MUST be capable of being driven without the use of a mouse, as the service engineer rarely has space on the bench to use a mouse.
Login Dialog
When the Service Software application is invoked, by checking on the Service Software icon, the Login dialog box will be displayed on the screen.
Nokia logo and application name
Application version
Copyright version
Login box
Nokia logo and application name bitmap () Displays Nokia logo and name of the application. Application version static text () Contains the name and version of the application. Copyright notice static text () Copyright is informed as: "Nokia Mobile Phones (c) 1996. All Rights Reserved". Login Box edit box () The user Login ID edit box, where the user enters his faultlog user name. (See Faultlog User Guide)
Original 03/98
Page 9
NSE1/3 Service Software Instructions
PAMS Technical Documentation
OK button (default key) The user name is stored in memory and the dialog box is closed. When the dialog box is closed, the application starts. Cancel button (ESC) The Dialog box is closed and application is started, but the Faultlog feature is disabled. Help button (F1) Activates the Windows Help application and displays context sensitive Help.
Main Window
Page 10
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Title bar The title bar is located at the top of the window. A title bar contains the following elements: · Application Controlmenu button · Maximise button · Minimise button · Name of the application · Restore button The properties of these elements and their usage is described in Ref 3 Microsoft Windows Version 3.1 Users Guide chapter one (Windows Basics) and chapter two (Application Basics).
Original 03/98
Page 11
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Menu bar The menu bar is below the title bar and contains all available menu selections. The menu bar is a dynamic element and is dependent on the dongle type fitted, and whether a phone is connected. Underlined characters in menu names and options indicates that the menu selection can be done by pressing Alt+ underlined character. Options can also be selected by activating menu bar with Alt key ( or F10 key ) and using arrowkeys to highlight the desired menu. In that case, selection is done by pressing Enter. Menus can also be selected by using the mouse as described in Ref 3Microsoft Windows Version 3.1 Users Guide Status bar The status bar is displayed at the bottom of the Service Software main window. The status bar contains information about the menu selections and events. The left area of the status bar describes the actions of menu items as the user uses the arrow keys to navigate through menus. The status bar texts are explained in detailed in each of command's description. The right areas of the status bar indicate which of the following keys are latched down: Indicator USER CAP NUM SCRL Tool bar The tool bar is NOT defined and will not be implemented until specified by this document. Description Entered Login ID. The Caps Lock key is latched down. The Num Lock key is latched down. The Scroll Lock key is latched down.
Page 12
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Menu Bar
The Service Software package will have two menu bar configurations. The first, is an abbreviated version that contains the minimum number of menus that allows package configurations when a phone is NOT connected. The second is described below: The menu bar MUST only contain the follow menus for the Service Software package when a phone is connected: · Product* · Configure* · Tuning · Testing · Software · Dealer · View · Help* * always displayed, even if no phone is connected. A menu is broken down into sections that are indicated with menu separators. Each sections identifies a logical difference from itself and other sections, i.e. between transmitter and receiver. Any items that are required to be added to a menu lists will be added on the bottom of the appropriate menu section list. If a new item is to be added which is common to two or more phone types, then that menu item will become a common menu item. The menu lists will use the Microsoft [...] symbol after an item name to indicate that selecting that item will NOT initiate an operation immediately, i.e. a dialog box will be displayed for the user to select options or type in data and press the OK button before the operation is performed.
Product
The Product menu contains the following menu items: · New · Open... · Close · Initialize ·Faultlog · Normal Mode · Local Mode F5 Shift+F5 Ctrl+R
· Activate Faultlog... F9 · Edit Faultlog... Alt+F4
· Exit
Original 03/98
Page 13
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Configure
The Configure menu contains the following items: · Options... · Directories... · Faultlog... · Phone Type Specific configuration items (where applicable)
Tuning
The Tuning menu contains the following menu sections: · RX Calibration... · Tx Power... · Tx I/Q... · Energy Management Calibration...
Testing
The Testing menu contains the following sections: · RF Controls... · RSSI Reading ... · Self Tests · ADC Readings · Audio · User Interface · Call Simulation · Noise Sensitivity... · IR Test
Page 14
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Software
The Software menu contains the following menu sections: · Product Profile... · Start Up Selftests... · Set Factory Values · Phone Identity... · Production Data Edit... · Flash Phone...
Dealer
The Dealer menu contains the following menu sections: · User Settings... · Short Code Memory... · SCM & User settings ... · Set UI/DEV Default Values ... · Postprogramming memory...
View
The View menu contains the following sections: · Quick/RF Info... · Phone Identity...
Original 03/98
Page 15
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Phone Identity Window The Phone Identity window should contain, as a minimum, the following data: · Software Version(s) · Hardware Version(s) · Serial Number(s) · Product Code This window will only be used as a display window and therefore will not allow editing of the displayed data. This window will not contain any controls other than a scroll bar.
Help
The Help menu contains the following menu items: · Index · General Help · Using Help · About WinTesla · About AS Locals
Page 16
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Mouse Cursors
The standards Windows pointer will be used as the mouse cursor. During time consuming tasks e.g. communication to phone, an hour glass will be shown informing the user that a task is in progress. The application uses the hour glass cursor to inform user that the application has taken the control and any actions from user will be ignored. When a function is initiated, the hour glass will be displayed and when the function has finished the mouse pointer will return to normal.
Reserved Keys
The following Hot keys and Short Cut keys are reserved either as Microsoft standard keys or as part of the Common Look and Feel specified by this document.
Short Cut Function Keys
Key by F1 F5 Shift+F5 F9 F10 Ctrl+F4 Description Defined
Context Sensitive Help Normal Mode Local Mode Activate Faultlog Goto Menu Bar Close Active Window
Microsoft NMP NMP NMP Microsoft Microsoft
Alt Hot Keys
Key by Alt+F4 Alt+H Description Defined
Exit Active Application Help
Microsoft Microsoft
Ctrl Hot Keys
Key by Ctrl+N Ctrl+O Ctrl+P Description Defined
File New File Open File Print
Microsoft Microsoft Microsoft
Original 03/98
Page 17
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Ctrl+R
Product New
NMP
Shift Hot Keys
Key by Shift+F5 Description Defined
Local Mode
NMP
Key Strokes
Key by Alt+P Alt+P,N Alt+P,O Alt+P,C Alt+P,I Alt+P,I,N Alt+P,I,L Alt+P,F Alt+P,F,A Alt+P,F,E Alt+P,X Alt+C Alt+C,O Alt+C,D Alt+C,F Alt+C,G Alt+T Alt+T,R Alt+T,X Alt+T,Q Alt+T,E Alt+E Alt+E,F Alt+E,R Description Defined
Product Menu New Open Close Initialize Popup Normal Mode Local Mode Faultlog Popup Activate Faultlog Edit Faultlog Exit Application Configure Option Directories Faultlog GPIB instruments (disabled) Tuning Menu RX Calibration Tx Power Tx I/Q Eanergy Management calibration Testing Menu RF Controls RSSI Reading
NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP Original 03/98
Page 18
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Alt+E,S Alt+E,A Alt+E,U Alt+E,U,I Alt+E,U,E Alt+E,U Alt+E,C Alt+E,N Alt+E,I Alt+S Alt+S,P Alt+S,S Alt+S,V Alt+S,I Alt+S,P Alt+S,F Alt+D Alt+D,U Alt+D,S Alt+D,M Alt+D,V Alt+V Alt+V,Q Alt+V,P Alt+H Alt+H,I Alt+H,G Alt+H,U Alt+H,A Alt+H,S
Self Tests ADC Readings Audio Audio Internal Audio External User Interface Call Simulation Noise Sensitivity IR Test Software Menu Product Profile Startup Self Tests Set Default Values Phone Identity Production Data Edit Flash Phone Dealer Menu User Settings Short Code Memory SCM & User Settings Set UI/DEV Default Values View Menu Quick/RF Info Phone Identity Help Menu Index General Help Using Help About WinTesla About AS Locals
NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP NMP Microsoft Microsoft Microsoft Microsoft NMP NMP
Original 03/98
Page 19
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Help Functions
The Help User Interface will be the standard Windows help tool called WinHelp. The context sensitive help is activated with F1key. Help contains also Using Help which describes how to use help facility. Refer to the Windows manual for detailed description on the Windows Help.
Dialog boxes
The Service Software application uses many different dialog boxes. Dialog boxes are used to display data and prompt the user for input. Dialog boxes are opened from menus or with shortcut keys. Dialog boxes have different properties but some features are common. All service dialog boxes must be modal, that is, the user will not be able to start another operation without first closing the present dialog box. All dialog boxes will contain the following entities: Help button Title bar At least one button other than Help Application Controlmenu Button
Common Dialog boxes
This sections describes the common dialog boxes used in the Service Software package, and the context in which they will be used. Note Message Box When the user has made an illegal selection, a note message box dialog will be opened and message text is displayed. The message box is also opened when the program has some information for the user. The size of the dialog box may vary. An information dialog box is recognized by the !icon.
The dialog box will also contain an OK button and a Help button. OK button (default key): Acknowledge displayed information and continue. The dialog box is closed after selection. Help button (Alt+H): Opens context sensitive help as F1key does. Original 03/98
Page 20
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Query Message Box Confirmations and questions are asked in a query message box. A query dialog box is recognized by the ?icon.
The dialog box will also contain a Yes button, a No button, and a Help button. Yes button (Alt+Y or Y) (default key): Accepts confirmation or question. No button (Alt+N or N): Denies confirmation or question. Help button (Alt+H): Opens context sensitive help as F1key does. The buttons may also be OK and Cancel. The operation of these buttons are the same as in the Note dialog box. Error Message Box Error message dialog boxes use the Stopicon. When a "Stop"dialog box is shown, the current operation is terminated. The dialog box has a description about the failed operation and reason. Pressing F1 (Help) application opens the appropriate help topic that gives information about recommended actions.
The dialog box will also contain an OK button and a Help button. OK button (default key): Acknowledges displayed information and terminate current operation. The dialog box is closed after selection. Help button (Alt+H): Open context sensitive help as F1key does.
Original 03/98
Page 21
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Custom Dialog boxes
All custom dialog boxes will contain the predefined buttons as defined below in the section Buttons. However, it is recognised that features may require additional button types, but the addition of these nonstandard buttons should be carefully considered to minimise any inconsistencies between implementations. The buttons will be positioned down the righthand side of the dialog boxes. The default action will be OK, except where that default action could result in an irretrievable failure. All tuning dialogs that contain tuning results, will display the old tuned data read from the phone before the tuning was performed, as well as the newly tuned data. List boxes will be used to display lists of data, such as tuning data, test results etc. The use of Radio buttons should be limited and carefully considered. The use of radio buttons defines the number of possible choices available to the user, which may be acceptable for one project, but not for another.
Buttons
All buttons must be the Microsoft style of buttons. In general, the default button will be the action button, the Close button or the Yes button, but this will depend on the context of the dialog box that the button is associated with. (action) button: Accepts and validates entered settings and values and closes the dialog. If the values have not been changed, then no action will be taken. The status bar will reflect the status. The user should only be queried, if the settings or values accepted will overwrite data that CAN NOT be reproduced. A greyed OK button indicates that settings selected by the user are not acceptable. Close button: Closes the current dialog box. Does not send or store anything and closes the dialog. The Close button is only used for dialogs that do not set or change any data. Cancel button (Esc): Cancel operation. Does not send or store anything and closes the dialog box. A greyed Cancel button indicates that it is not possible to quit from this dialog box.
Page 22
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Yes button (ALT+Y or Y): Replies Yes to a question asked of the user. No button (ALT+N or N): Replies No to a question asked of the user. Help button (ALT+H): Opens context sensitive help as F1key does.
Reporting Status
The status bar will be used to report the present status to the user. When a feature is initiated, the status bar will be updated with a brief description of the function. The status bar will also be updated at key points in a time consuming function. If an error is to be reported to the user, it will be displayed in the status bar as well as displayed in a common error dialog box. This will mean the user is not delayed from progressing on to the next operation unless an error occurs, in which case, the user will have to acknowledge the error by pressing the OK button.
Original 03/98
Page 23
NSE1/3 Service Software Instructions
PAMS Technical Documentation
NSE1/3 FEATURES Menu bar
After Sales SW's menus follows the menu structure specified in WinTesla User Interface Specification /9/. This specification will describe functionality that differs from WinTesla specification.
Product
New command Activation Alt, P, N Ctrl+R If phone is changed (with same phone type only serial number is changed) phone will be initialised to local mode. If phone is changed to different phone type the current DLLs are unloaded and new ones are loaded for that phone. If the Quick/RF Info view is open, window will be automatically updated. If Phone Information view is open, it will be automatically updated. Open... command Activation Alt, P, O Status Bar Text Force load phone specific functionality Status Bar Text Rescan a new phone
Phone is set to local mode. Initialise... command Activation Alt, P, I Opens a submenu Status Bar Text
Page 24
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Normal Mode Activation Alt, P, N F5 When normal mode has been activated or program has been started, selftest results will be asked from MCU. If any fault was found in the tests, an error message is shown. If normal mode has been set successfully (no self test error has been found), and paging listening has been started, the used AFC value is requested from MS. Initialisation routine checks phone's cellular type and if unsupported phone is detected, application unloads the DLLs. The After Sales SW sets automatically the MS state to normal mode when needed. If phone identification view is open, window will be automatically updated. Also if RF Information Window is open it will be updated to quick info view. Local Mode Activation Alt, P, L Shift+F5 Selection will change the MS state to local. When user selects item from Testing or Tuning menus, the After Sales SW software will change automatically the MS state to local. The After Sales SW sets automatically the MS state to normal mode when needed. Also if quick info view is open it will be updated to RF Information view. Status Bar Text Initialises phone to local mode Status Bar Text Initialises phone to normal mode
Original 03/98
Page 25
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Tuning
The tuning menu offers functions for ME adjustments. RX Calibration... command Activation Alt, T,R Starts RX calibration. The next automatic selections are made when this tuning function is activated: · · Phone is set to local mode Update RF information window Status Bar Text Open RX Calibration dialog box
The measurement is started automatically when RX calibration is entered. The measurement is done in five steps: 1. User is requested to put signal generator to high input level (read from .INI file).
2. Measurement with high input level is executed 3. User is requested to put signal generator to low input level (read from .INI file).
Page 26
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
4. Measurement with low input level is executed 5. The RX Calibration dialog will be updated when previous steps are done.
Dialog mode: modal RX Calibration dialog has the following items: AFC information box: Shows AFC init value, AFC slope and PSW slope values. AGC List box (ALT+A): AGC, DAC, Voltage and Difference. The difference column shows the difference between tuned DAC values and mean straight line calculated from part slopes in dBs (see /1/). This can be calculated when all measurement results have been received from phone. Repeat button (ALT+R): The measurement can be started again by pressing this button. Save button (ALT+S): Dialog is closed and tuning is saved to phone. Cancel button (ESC): Dialog is closed and tuning is not saved to phone.
Original 03/98
Page 27
NSE1/3 Service Software Instructions
PAMS Technical Documentation
When calibration is ended, the DAC value checking is made and if it is not succeeded, error message is shown. When exit is made, the next selections are set to the values which were selected before this adjustment. Operation Mode Update RF Information window The exit and the use of AGCcontrol values is done same way as exit from power level tuning and power coefficient use: Tx Power... command Activation Alt, T,X Status Bar Text Open TX Power Tuning dialog box
Starts TX power tuning. User is first requested to select with which values tuning is started in Start Tuning dialog.
Start Tuning dialog has following items: Start Tuning With list box (ALT+S): Current Values in PC memory Tuning values are load from program's internal memory. EEPROM Values Tuning values are load from ME's EEPROM. Factory Default Values Tuning values are load from ME's flash. The next automatic selections are made when this tuning function is activated: the lowest (19) power level is selected Operation mode = TX pulsed
Page 28
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
The TX Power Tuning dialog will be activated automatically after value selection.
Dialog mode: modal TX Power Tuning dialog has following items: Power Level & Coefficients list box (ALT+L): The power is presented in GSM or PCN values. The base power is selected automatically when the dialog is opened. The test value is not saved to the EEPROM. The test value can be changed during tuning as other power coefficients and the program remembers its value when tuning function is activated later again. If there is more power levels in the phone that can fit into window the window is scrollable. When phone is initialised the program asks the number of power levels used in the phone. Only three power coefficients (highest, third smallest and lowest) are needed to tune (left justified Coefficients) and the rest of them are calculated. The tuning position is highlighted and can be tuned with +/ keys or left/ right cursor keys. Calculate button (ALT+C): The calculation is activated with this button. The power coefficients which are calculated from the tuned coefficients are displayed on the different columns than the others. All values can be tuned if needed. Base level calculation check box: If this box is checked the base level is calculated.
Original 03/98
Page 29
NSE1/3 Service Software Instructions
PAMS Technical Documentation
+/ buttons (+/ and left/right cursor keys): + and buttons will cause power changing by 0.25dB steps. When these keys are used the coefficient value is updated on the tuning window. Save button (ENTER): Dialog is closed and tuned values are saved to phone. Cancel button (ESC): Dialog is closed and tuning is not saved to phone. When selections are used, the power value checking is made and if it is not succeeded, error message is shown. The test checks that all power coefficients are in descending order (same order than power levels). If the power tuning function is ended and EEPROM values are not received or EEPROM fault is noticed, an error message is shown. When all power coefficients have such values that they don't cause any error messages, save can be made. The last used tuning power is in use after exit. The next automatic selection is made when this tuning function is ended: Operation Mode = RX pulsed Tx I/Q... command Activation Alt, T,Q Status Bar Text Open TX I/Q Tuning dialog box
This function is used for tuning TX I and Q branch DC offset, amplitude difference and phase difference. The function opens same Start Tuning dialog as with TX Power Tuning. The next automatic selections are made when this function is activated: Operation Mode = TX pulsed Update RF Information window The TX I/Q Tuning dialog is opened.
Dialog mode: modal Original 03/98
Page 30
PAMS Technical Documentation
NSE1/3 Service Software Instructions
TX I/Q Tuning has following items: Tune TX I DC Offset scroll bar (ALT+I): The DC Offset is shown as percents (%) from the ± maximum value. 0% means that there is no DC. The value range is 100%...100%. The value is rounded to the nearest integer value. Tune TX Q DC Offset scroll bar (ALT+Q): The operation of this function is the same as one above, except with this selection the Q branch DC Offset is tuned. The value range is 100%...100%. The value is rounded to the nearest integer value. Tune Amplitude Difference scroll bar (ALT+A): When this selection is made user can increase or decrease the amplitude difference within 0.1 dB steps. The value range is 1...1. Tune Phase Difference scroll bar (ALT+P): When this selection is made user can increase or decrease the phase difference within 0.5° steps. The current phase difference is shown on the tuning window with numbers and bar figure. The value range is 85...90. Save button (ENTER): Dialog is closed and tuning is saved to phone. Cancel button (ESC): Dialog is closed and tuning is not saved to phone. After each value change the new value is sent to the phone. The next automatic selection is made when TX I / Q tuning function is ended: Operation Mode = RX pulsed Update RF Information window
Original 03/98
Page 31
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Energy Management Calibration... command Activation Alt, T,E Status Bar Text Calibrate Battery Voltage
This function is for battery a/d and charge current tunings. Before battery a/d tuning is started a voltage setting request is shown to user (Set supply voltage to 10,5 V). When external power is connected and user selects Yes to continue, the application displays the Energy Management Calibration dialog box:
Dialog mode: modal Energy Management Calibration dialog has following items: Settings group box: Contains EM calibration setting checkboxes: 1. Run battery & charger default values checkbox (ALT+1): Runs battery & charger default values to phone when selected 2. Battery voltage checkbox (ALT+2): Calibrates battery voltage A/D value. Original 03/98
Page 32
PAMS Technical Documentation
NSE1/3 Service Software Instructions
3. Charger voltage checkbox (ALT+3): Calibrates charge voltage A/D value. 4. Battery size checkbox (ALT+4): Calibrates battery size A/D value. 5. Battery temperature checkbox (ALT+5): Calibrates battery temperature A/D value. 6. Charge current checkbox (ALT+6): Calibrates charging current. Save without confirmation checkbox (ALT+S): When selected, all selected calibrations are saved to phone without confirmation, otherwise user must confirm every A/D value saving to phone. Calibration info listbox (ALT+S) Shows information about current calibrations. Run button (ENTER): All selected settings are executed. Close button (ESC): Dialog is closed. Help button (ALT+H): Context sensitive help. After battery a/d tunings a voltage setting request is shown to user (Set supply voltage to 8.0 V).
Original 03/98
Page 33
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Testing
The Testing sub menu offers functions for ME testing. RF Controls... command Activation Alt, E,R Status Bar Text Open RF Controls dialog box
This function is used for RF testing. Command opens RF Controls dialog, which contains data for testing and adjustments.
Dialog mode: modal RF Controls dialog has following items: Active Unit group: RX radio button (ALT+R): When RX is selected, the next functions are made: Data transmission is deactivated TX power is deactivated If operation mode is continuous, AGC is controlled RX continuous mode channel is activated RF Information window is updated The RX value is always given as default. Original 03/98
Page 34
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Note! Function is activated immediately, Apply is not needed. TX radio button (ALT+T): When TX is selected, the next functions are made: Data transmission is activated If operation mode is continuous, Operation mode is set to burst RF Information window is updated Continuous mode radio button is disabled. Note! Function is activated immediately, Apply is not needed. Operation Mode group: Continuous radio button (ALT+C): When continuous selection is used, synthesiser is set to constant frequency synthesiser channel number is as given with Continuous Mode Channel selection transmitter power is not connected if Active Unit is RX, AGC is controlled Note! Function is activated immediately, Apply is not needed. Burst radio button (ALT+B): When burst selection is used, synthesiser is controlled by using receiving/transmission/measuring synthesiser control sequence synthesiser channel numbers are as given with Channel/Monitoring Channel selections if Active Unit is TX, data (selected with TX Data Type) is sent and the TX power is connected Note! Function is activated immediately, Apply is not needed. TX Data Type drop list (ALT+D): TX Power Level edit box (ALT+T): With this value is possible to change the transmission power. The user can give the needed power value or select the test value, which is tuned with TX power tuning function. The test value is found at the end of the list. TX Power have value OFF and is disabled (greyed) when active unit is RX. When the TX power is tuned with test value (smallest value) the TX Power has value TEST.
Original 03/98
Page 35
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Channel edit box (ALT+H): User can enter here channel number that is used for both transmission and receiving. The frequency of the selected channel is shown after selection. Monitoring Channel edit box (ALT+M): This field selects neighbour monitoring channel. The frequency of the selected channel is shown after selection. Continuous Mode Channel edit box (ALT+C): To this edit box user can type continuous mode channel which may have all channel numbers. The used frequency depends on the Active Unit. If Active Unit is RX, then RX frequency is used, else TX frequency. The frequency of the selected channel is shown after selection. AGC Absolute edit box (ALT+A): This selection allows user to edit AGC absolute value (value from A/D converter). When AGC Absolute value is changed the AGC dB value will be calculated depending on the AGC Absolute value. Front End On check box: This selection allows user to change whether the Front End amplifier is On or Off. AGC edit box (ALT+G): This selection allows user to edit AGC absolute value (value from A/D converter). AGC value is shown only when its value is controlled by PC. When Active Unit has value RX and Operation Mode is continuous, AGC is controlled by PC except when next adjustment functions are activated: RSSI Calibration AFC Diagram Apply button (ALT+A): Accepts entered values and validates them. After validation application sends corresponding messages to ME. Closes dialog and updates Info Window. Note! Active Unit and Operation mode are not send with because they are activated immediately. Set Defaults button (ALT+S): Sets current values as default Rf Controls values. Get Defaults button (ALT+G): Gets default Rf Controls values as current values. The next automatic selection is made when Quick testing function is ended: Original 03/98
Page 36
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Active Unit = RX Update RF Information window The next table shows the dialog's properties on different situations: ACTIVE UNIT = TX: TX Data Type: Updated AGC values: Greyed Monitoring Channel: Greyed OPERATION MODE = BURST: TX Power Level: Updated Continuous Mode Channel: Greyed Channel: Updated ACTIVE UNIT = RX: TX Data Type: Greyed TX Power Level: OFF, Greyed OPERATION MODE = BURST: AGC values: Greyed Continuous Mode Channel: Greyed Channel: Updated Monitoring Channel: Updated OPERATION MODE = CONT: AGC values: Updated Continuous Mode Channel: Updated Channel: Greyed Monitoring Channel: Greyed
Original 03/98
Page 37
NSE1/3 Service Software Instructions
PAMS Technical Documentation
RSSI Reading... command Activation Alt, E,R Status Bar Text read continuously RSSI value
Command opens RSSI Reading dialog:
Dialog mode: modal RSSI value is read continuously until user presses ESCkey or Close button to cancel reading. RSSI Reading dialog has following items: Close (ENTER) button: Closes the RSSI Reading dialog. Does not send anything to phone. Help button: Context sensitive help. Self Tests... command Activation Alt, E,S Status Bar Text Open MCU Selftests dialog box
Command is used for reading self test results and running self tests. When the selection is made, the test result is read from ME. The test result will be shown to the user within MCU Selftest dialog.
Page 38
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Dialog mode: modal MCU Selftest dialog has following items: Tests list box (ALT+T): The field "(p)" in the screen example means that the test is also run in power up. The field "/s)" means that this test is selectable one. Test states are updated according to results received from the phone. Possible test states will be one of the next: Passed Failed No response Not executed Not valid RUNNING.... Note that poweroff test have no values, because if test has been passed, power has been turned off. If poweroff test fails a special error message window is shown. If no response is received to power off test message in a few seconds, the user is informed by special info window, where user is asked to turn the power on and then press the return key. Note also that poweroff test (if passed) turns power off and power should be reconnected by using the phones keypad after the successful test. After the power has been connected to phone, the normal startup
Original 03/98
Page 39
NSE1/3 Service Software Instructions
PAMS Technical Documentation
routines are made and the selftest results are shown in the MCU self tests menu (i.e. all other than powerup selftests are in Not executed state after the powerup routines). Run button (ALT+R): User can select desired test from list and hit Run button. When user selects test to be run the text RUNNING... is shown in test state field and test is run. When results are received the test state field is updated according to the result. If no response was received in the defined time, a error message box will be shown and the test state is changed to No response. Phone is set to local mode if it is not already there. Run All button (ALT+A): User can run all listed tests. The text RUNNING... is shown in test state field and test is run. When results are received the test state field is updated according to the result. When state field is updated application moves to next test and repeats previous cycle. Phone is set to local mode if it is not already there. Supported Self Tests 1 MCU ROM Checksum................ 2 MCU RAM Interface............... 3 MCU RAM Component............... 4 MCU EEPROM Interface............ 5 MCU EEPROM Component............ 6 RTC Battery..................... 7 CCONT Interface................. 8 A/D Converter................... 9 SW Reset........................ A Power Off....................... B Security Data................... C EEPROM Tune Checksum............ D PPM Checksum.................... E MCU Download DSP................ F DSP Alive....................... G COBBA Serial....................... H COBBA Parallel..................... I EEPROM Sec Checksum................ K PPM Validity.................... Original 03/98
Page 40
PAMS Technical Documentation
NSE1/3 Service Software Instructions
ADC Readings... command Activation Alt, E,A Status Bar Text Open ADC Readings dialog box.
Command is used to read and show A/D values from phone. Command opens ADC Readings dialog.
Dialog mode: modal ADC Readings dialog has static text field where measurements are updated to window every one second. ADC Readings dialog has following items: Close (ENTER) button: Closes the ADC Readings dialog. Does not send anything to phone. Help button: Context sensitive help.
3.1.4.4.1 A/D Readings
Following a/d readings are measured: Battery Voltage.........: Battery Temperature.....: Charge Voltage..........: Charge Current..........: Battery Type............: Acessory Detection......: Hook....................: RSSI....................: VCXO Temperature........:
Original 03/98
Page 41
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Audio... command Activation Alt, E,U Opens a submenu which contains following options: Internal Audio Loops Activation Alt, E,U,I Status Bar Text Open Internal Audio loops dialog box. Status Bar Text
Command is used for making internal audio loop tests in Internal Audio Loops dialog.
Dialog mode: modal Internal Audio Loops dialog has following items: Buzzer Volume group: Next three different values can be selected for Buzzer volume: Volume On radio button (ALT+V): Turns buzzer on. Volume Off radio button (ALT+O): Turns buzzer off. Level drop down list (ALT+L): Sets level of a buzzer. Allowed range 0...127 Original 03/98
Page 42
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Internal Audio Loop group: Input group: Next two different values can be selected for input: Internal radio button (ALT+I): Turns internal input. External radio button (ALT+I): Turns external input. Headset radio button (ALT+A): Turns headset input. Output group: Next two different values can be selected for output: Internal radio button (ALT+T): Turns internal output. External radio button (ALT+X): Turns external output. Headset radio button (ALT+D): Turns headset output. Loop group: Next two different values can be selected for loop: Off radio button (ALT+F): Turns audio loop off. On radio button (ALT+N): Turns audio loop on. When dialog is closed with the Buzzer Volume is switched always off. Also internal audio loop is turned off.
Original 03/98
Page 43
NSE1/3 Service Software Instructions
PAMS Technical Documentation
External Audio Loops Activation Alt, E,U,E Status Bar Text Open External Loops dialog box
Command is used for making external audio loop tests in External Audio Loops dialog.
Dialog mode: modal External Audio Loop dialog has following items: Interface group: Next two different values can be selected: HS radio button: Turns interface to HS (handset) HF radio button: Turns interface to HF (handsfree).. Test button: Starts the external audio loop test. Cancel button: Closes the External Audio Loop dialog. Sends nothing to phone. Help button: Context sensitive help. Measurements group: Contains received levels for used frequencies. If received level is out of range that is displayed top of measurements group box.
Page 44
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
User Interface... command Activation Status Bar Text
Alt, E,U Open User Interface Tests dialog box Command is used for making display tests in Display Tests dialog.
Dialog mode: modal Display Tests dialog has following items: 1. Test Pattern radio button (ALT+1): In test display 1 all indicators are displayed and the display is filled with chessboard letters. 2. Test Pattern radio button (ALT+2): In test display 2 none of the indicators are displayed and the display is filled with inverse chessboard letters. When dialog is closed the phone LCD display is cleared. Call Simulation... command Activation Status Bar Text
Alt, E,C Open Call Simulation dialog box Command is used for making call simulation. Function opens Call Simulation dialog.
Original 03/98
Page 45
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Dialog mode: modal Call Simulation dialog has following items: TX Power Level edit box (ALT+T): All power levels can be selected. This updates same parameter as TX Power Level in the RF Controls dialog. Note that TEST value cannot be selected. If TEST value was in use when Call simulation menu selected, power level is changed to smallest value. Channel edit box (ALT+C): This tells the normal operating RF channel number. Normal GSM/PCN channel numbers can be selected. Same channel is used both for transmission and receiving. This updates same parameter as Channel in the RFControls dialog. Channel 1,2,3,4,5,6 edit box (ALT+1,2,...): Channels for monitoring are specified with these six selections. All GSM/ PCN channel numbers can be used. If more than one selection has same number, the monitoring channel list (neighbour list) will have less than 6 selected channels. The minimum number of monitoring channels is one (all channels have same value). The monitoring channel can also have same value as normal operating channel. The first monitoring channel updates same parameter as Monitoring Channel in the RFControls dialog. Apply button (ALT+A): Validates and sends entered data to ME. Set Defaults button (ALT+S): Sets current values as default Call Simulation values. Get Defaults button (ALT+G): Gets default Call Simulation values as current values.
Page 46
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Noise Sensitivity... command Activation Status Bar Text
Alt, E,N Opens Noise sensitivity dialog box Command is used for noise sensitivity measurement. The next automatic selections are made when this tuning function is activated: Operation mode = RX cont AGC = 81 dB Before function opens Noise Sensitivity dialog application prompts:
Then application opens Noise Sensitivity dialog:
Dialog mode: modal Noise Sensitivity dialog has following items: Measurements group: Clipping distance is the difference to the signal clipping value. SNR is measured in AD converter.
Original 03/98
Page 47
NSE1/3 Service Software Instructions
PAMS Technical Documentation
The last value on the display is signal power difference between I and Q branch. The numbers are shown in 0.1dB accuracy. The error messages, "OUT OF RANGE", are shown only if the SNR and/or amplitude difference values are not acceptable. Signal/Noise radiobutton (ALT+S/ALT+N): When buttons are pressed, the RX I and Q burst data is asked, text "SIGNAL MEASURING..." or "NOISE MEASURING..." will come to the measurement group window. The power level value should be 92 dBm during signal measurement. When signal data is received, distance to clipping signal level is shown as dBs on the display. When either signal or noise measurement results are received "MEASURING" text is removed and measurements are updated to screen. When both measurements (signal and noise) are done at least once, the signal to noise relation and difference are also shown on the display. When exit is made, the next selections are set to the values which were selected before this adjustment. Operation mode AGC value IR Test... command
NOTE! Applies only to phones equipped with Infrared ports.
Activation Alt, E,I Status Bar Text IR module test
Command is used for making IR module test. Function opens IR Test dialog:
Dialog mode: modal IR Test dialog has following items: Result box: Result can be OK/FAILED Test (ENTER) button: Starts IR Test. Close button: Original 03/98
Page 48
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Closes the IR Test dialog.
Software
Product Profile... command Activation Alt, S,P Status Bar Text Open Product Profile settings dialog box.
Function is used for making product profile settings. When command is activated the product profile information is read from EEPROM and Product Profile dialog is opened.
Dialog mode: modal Product Profile dialog has following items: Settings list box (ALT+E): A list where user can select desired setting. User can toggle setting with following Options drop list or by double clicking desired setting in list box. Options drop list (ALT+O): List allows user to set options to each settings which are listed in Settings list box. Save(OK) button (ENTER) Selections are accepted and saved to EEPROM. Cancel button (ESC) Selections are ignored and control is returned back to main menu.
Original 03/98
Page 49
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Start Up Selftests... command Activation Alt, S,S Status Bar Text Open MCU start Up selftests dialog box.
Function is used for changing the state of the EEPROM selectable tests in MCU Start Up Selftests dialog.
Dialog mode: modal MCU Start Up Selftests dialog has following items: Tests list box (ALT+T): When dialog is opened, the previous values will be read from the MCU EEPROM and shown on the list box. Status group: When radio button On is selected, the test will be run every time when automatic start up selftests are activated (e.g. in power up). Save button (ENTER) Selections are accepted and saved to EEPROM. A power up routine is made to phone. Cancel button (ESC) Selections are ignored and control is returned back to main menu. Selectable StartUp self tests: 1. PPM Validity 3. A/D Converter
Page 50
Original 03/98
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Set Factory Values... command Activation Alt, S,V Status Bar Text Set factory values
Application does not ask confirmation. Next kind of text will be shown to user: "Setting UI and SCM Factory values..."
Dialog mode: modal Default Factory Values dialog has following items: Settings list box: Contains the selectable factory values. Set button: Sets the selected factory value to phone. Before setting software asks confirmation:
Cancel button: Closes the Default Factory Values dialog.
Original 03/98
Page 51
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Phone Identity... command Activation Status Bar Text
Alt, S,I Open Phone Identity dialog box for editing Function is used to edit phone identity. With this dialog IMEI or SIM locks may be changed in following manner: current phone information is read from phone user edits User Name (and IMEI and Product Code, if they were not read correctly from phone) dialog information is saved to file, which is sent to secure place where actual programming information may be constructed programming information is got from secure place in an other file, which is loaded to dialog program checks input values and if they are correct programming information is written to phone Function opens Phone Identity dialog.
Dialog mode: modal Phone Identity dialog has following items: User Name edit box (ALT+U): Field where user can enter user identification. IMEI edit box (ALT+I): Field where user can enter IMEI value. Field can contain up to 40 digits.This field is automatically filled, if ME is connected to the PC when dialog is loaded. Original 03/98
Page 52
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Product Code edit box (ALT+P): Field where user can enter Product Code value. This field is automatically filled, if ME is connected to the PC when dialog is loaded. MS Id edit box (ALT+M): Field where user can enter MS Id corresponding programming data. This field is automatically filled, if ME is connected to the PC when dialog is loaded. Product Id edit box (ALT+R): Field where user can enter Product Id. This field is automatically filled, if ME is connected to the PC when dialog is loaded. Dongle Serial nr. edit box (ALT+N): Field where user can enter Product Id. This field is automatically filled, if ME is connected to the PC when dialog is loaded. Data edit box (ALT+A): Field where user can enter Data entry. This field is automatically filled, when file is loaded or data is saved. IMEI radio button: File and ME operations contains only IMEI data. SIM Lock radio button: File and ME operations contains only SIM Lock data. IMEI Programming Data edit box (ALT+I): IMEI programming data is read from file or entered by user to this field. SIM Lock Programming Data edit box (ALT+D): SIM Lock programming data is read from file or entered by user to this field. Close button (ESC): Cancels all edits and does not save values to phone. Help button Opens a help text. Write button (ALT+W): Writes programming data to phone. Actions are selected with Action Selection radio button. Read button (ALT+R): Reads identification data from phone and shows it in dialog controls. Needed data is selected by Action Selection radio button. Save File... button (ALT+S):
Original 03/98
Page 53
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Writes a file containing data needed by security place application to create needed programming data. File is selected with File Save As dialog. Load File... button (ALT+L): Reads a file containing data needed to program selected data. File is selected with File Open dialog. Warranty State... command Activation Alt, S,W Status Bar Text Open Warranty State dialog box
This command is used to set the warranty state of a phone. When selected application opens Warranty State dialog box.
Dialog mode: modal Warranty State dialog has the following items: State static text: USE For nomal phones. DEFECTIVE For phones which are being swapped. A warranty and other information is transferred to the working phone. EXCHANGE For phones which are already repaired from DEFECTIVE one. Repair Date edit box: When Warranty State is USE and PKD1CS or PKD1NS dongle is connected user can edit repair date. Otherwise field is read only. Format is MMYY, where MM stands for month digits and YY stands for year digits. Warranty Date edit box: When state is DEFECTIVE and PKD1CS or PKD1NS dongle is connected user can edit warranty date. When warranty date Original 03/98
Page 54
PAMS Technical Documentation
NSE1/3 Service Software Instructions
is saved warranty state will be EXCHANGE. Format is MMYY, where MM stands for month digits and YY stands for year digits. OK button (ENTER): Closes the dialog box and saves the edited date to the phone. This button is enabled only when phone is Repair Date or Warranty Date is changed. Cancel button (ESC): Closes the dialog box and does not save the warranty state to the phone. Production Data Edit... command Activation Alt, S,P Status Bar Text Open Production Data Edit dialog box
This command is used for programming HW version to phone. Function opens the following Production Data Edit dialog box.
Dialog mode: modal Production Data dialog has the following items: Production Code edit box (read only): Displays production code. Order Number edit box (read only): Displays order number. Production Ser. No edit box (read only): Displays production serial number. Manufacture Month edit box (read only): Displays manufacturing month. HW Version edit box: User can edit HW version.
Original 03/98
Page 55
NSE1/3 Service Software Instructions
PAMS Technical Documentation
OK button (ENTER): Closes the dialog box and writes HW version to ME. Cancel button (ESC): Closes the dialog box and does not write HW version to ME. Flash Phone... command Activation Alt, S,F Status Bar Text Open service Numbers dialog box
This command is used for flashing new software into the phone. Function opens the following Flash dialog box. When flashing is started, waiting windows is showed which tells the user approximated flashing time.
Dialog mode: modal Flash dialog box has following items: Flash Image edit field (read only): Displays path of image file to be flashed. PPM Image edit field (read only): Displays path of PPM package file to be flashed. PPM Version edit field (read only): MCU SW version string of the PPM package. PPM File Versions edit field (read only): Lists the file versions of PPM package. Flash button (ALT+L): Original 03/98
Page 56
PAMS Technical Documentation
NSE1/3 Service Software Instructions
Starts flashing of selected file to phone. Before flashing asks, does user want to save all user settings to file (and load them after flashing). If reading user settings to ME or writing them to ME failed, Restore Default User Settings dialog is opened and user can restore default settngs to phone. See Error! Reference source not found. Error! Reference source not found.. Load Image button (ALT+I): Opens Open File dialog, with which user can select a image file to be flashed to ME. If user selects OK button, the name of selected file is copied to Flash Image edit field. Load Ppm button (ALT+P): Opens Open File dialog, with which user can select a PPM package file to be flashed to ME. If user selects OK button, the name of selected file is copied to PPM Image edit field. LPT Port list box: User can select parallel port to be used when flashed. Blonde check box: When control is checked, application searches from file blonde.ini for section corresponding product and HW version (e.g [NSE3_2304]). If section is found and contains entries Ppm and Image, those files are loaded for flashing. [NSE3_2502] Ppm=ppm_file_path Image=image_file_path Blonde settings are checked when dialog is opened and check box status tells, is there blonde settings for current phone. Notice: if user wants to load other files than succested in blonde.ini file, then Blonde files check box must be unchecked. Close button (ESC): Closes the dialog box and does not start flashing. During flashing status dialog is showed. After phone is flashed current time in PC is set to phone and user is asked to check that the time is correct.
Original 03/98
Page 57
NSE1/3 Service Software Instructions
PAMS Technical Documentation
Dealer
The dealer sub menu offers functions for ME settings for dealers. User Settings... command Activation Alt, D,U Status Bar Text Open User Setting dialog box
This command is used to edit user settings.
Dialog mode: modal User Settings dialog box has following items: Save