Text preview for : 07_SSI.pdf part of Nokia 9210 Service Manual Cellular Phone/Personal Digital Assistant - (9,32Mb) Part 1/5 - File 14
Back to : RAE-3_cellular_®_.part1.r | Home
PAMS Technical Documentation RAE-3 Series PDA
7. Service Software Instructions
Issue 1 06/01
Copyright E 2001. Nokia Mobile Phones. All Rights Reserved.
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
AMENDMENT RECORD SHEET
Amendment Number Date Inserted By OJuntunen Comments
06/01
Page 7 2
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
CONTENTS Troubleshooting Page No
Service Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware requirements for Windows 3.1x . . . . . . . . . . . Hardware requirements for Windows 95 . . . . . . . . . . . . Software Environment of the Support Modules . . . . . . . . . Required Servicing Equipment . . . . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the software on PC Hard Disk . . . . . . . . . . . . . Common Properties of the User Interface . . . . . . . . . . . . . . . . . . Login Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Main Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RAE-3 software upgrade guide . . . . . . . . . . . . . . . . . . . . . . . . . . . Equipment Setup instructions . . . . . . . . . . . . . . . . . . . . . . . . . . Setting up the PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setting up BUS Configuration for WinTesla . . . . . . . . . . . . Programming with WinTesla Interface . . . . . . . . . . . . . . . . . . . Troubleshooting for the N9210 SW upgrade . . . . . . . . . . . . . . Wintesla Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RF tuning after repairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Equipment Setup for RF Tuning without Removing Covers . RX Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RX Filter Calibration (Automatic) . . . . . . . . . . . . . . . . . . . . . RX AM Suppression (automatic) . . . . . . . . . . . . . . . . . . . . . EGSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PCN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TX Power Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EGSM tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PCN tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TX I/Q Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Common tuning procedure . . . . . . . . . . . . . . . . . . . . . . . . Initial setup PCN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IQ Tuning using Spectrum Analyzer . . . . . . . . . . . . . . . . . . . . . EGSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spectrum Analyzer Settings . . . . . . . . . . . . . . . . . . . . . . . Phone Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PCN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spectrum Analyzer Settings . . . . . . . . . . . . . . . . . . . . . . . Phone Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 75 75 75 75 76 77 77 77 78 78 79 79 7 10 7 10 7 11 7 11 7 12 7 16 7 18 7 18 7 19 7 20 7 23 7 25 7 25 7 27 7 29 7 29 7 31 7 33 7 34 7 35 7 36 7 36 7 36 7 36 7 41 7 41 7 41
Issue 1 06/01
Page 7 3
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Energy Management (EM) Calibration . . . . . . . . . . . . . . . . . . . Equipment Setup for Energy Management calibration . . . Energy Management Calibration procedure . . . . . . . . . . . .
7 46 7 46 7 47
Page 7 4
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Service Software
General
Wintesla software is used to perform service functions of the RAE3 PDA. This SW consists of Wintesla service software and product specific DLL's (Dynamically Linked Libraries). To run WinTesla SW, a parallel port software protection device (PKD1) must be connected to the PC to perform flashing functions. If only controls are necessary, RAE3 can be controlled using equipment setup described in the WinTesla RS chapter. The test functions send test messages from PC to MS and receive results and show them in the PC display. The messages to the phone can be sent via DAU9C cable. Note: if this software is to be run on laptops, the power saving feature MUST be switched off. Hardware requirements for Windows 3.1x The recommended minimum hardware standard to run Service Software is any computer which is 386 33 MHz or greater with at least 4 MB of memory and VGA type display (640 x 480). This assumes that only the WinTesla with After Sales Support Modules is active, i.e. other Windows packages are not running in the background. Hardware requirements for Windows 95 The recommended minimum hardware standard to run Service Software is any computer which has Pentium processor, memory 8 MB and meets HW requirements recommended by Microsoft.
Software Environment of the Support Modules
The Service Software user interface is intended for the following environments: Microsoft Windows 3.1x (enhanced mode) and Windows 95/98 and NT. Detailed information about Windows and application usage can be found from the Microsoft Windows Users Guide. As an ordinary Windows application, the main idea in the user interface is that selections are made with menus, push buttons and shortcut keys. Selections can be done by using keyboard and/or mouse. There is always a status bar displayed at the bottom of the main window which contains information about current actions.
Issue 1 06/01
Page 7 5
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Required Servicing Equipment
Computer: At least IBM 80386 or compatible with one unused serial port (COM1 or COM2) *), one parallel port (LPT1), hard disk recommended Operating System: DOS Version 3.2 or later If PCLStart in use: DOS 6.22 and IBM 80486 or compatible Display: Any 80character text display Service software version for 3.5" disk (product code: 0774080) Rest of the needed service equipment depends on what kind of operations service personnel wants to perform.
*) Note: A number of PC's of an older generation use the Intel, National Semiconductor, or United Microelectronics IC 8250 as the serial port UART. This is a comparatively inefficient circuit for current purposes and does not necessarily support the M2BUS adapter at 9600 baud. The newer UART's NS16450 and NS16550AF of National Semiconductor offer solutions for these problems.
Page 7 6
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Installation
Mechanical Connections
Caution: Make sure that you have switched off the PC and the printer before making connections. Caution: Do not connect the PKD1 key to the serial port. You may damage your PKD1 ! The software controls RAE3 via a separate adapter connected to the serial port of the PC, and to the phone bottom connector (DAU9C cable). Attach the dongle PKD1 to the parallel port 1 (25pin female Dconnector) of the PC. When connecting PKD1 to the parallel port, be sure that you insert the computer side of the PKD1 to the PC (male side). If you use a printer on parallel port 1, install the PKD1 between the PC and your printer cable. The PKD1 should not affect devices working with it. If some errors occur (errors in printing are possible) please try printing without the PKD1. If printing is OK without the PKD1 please contact your dealer. We will offer you a new PKD1 in exchange for your old one. The program is delivered on a diskette and is copy protected with a dongle PKD1. It must be present in parallel port when using Service software.
Installing the software on PC Hard Disk The program can also be installed on the hard disk, which is recommendable to obtain a maximum data access rate. Keep the original diskette safe to enable upgrading of the program ! If you plan to use PCL Start service software, you must install it before installing Service software, see PCL Start installation instructions. To install the new Service software program, follow the steps below: insert the new Service software diskette into drive A: of your computer 2. start Windows, and open File Manager log into drive a: type A: and press 3. start INSTALL.EXE and type C: and press install Service software to drive C: To install product specific DLL's, take your RAE3 DLL disks, and repeat the steps above. 1.
Issue 1 06/01
Page 7 7
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Common Properties of the User Interface
This chapter describes how the User Interface CLF must appear to the user. The User Interface MUST be capable of being driven without the use of a mouse, as the service engineer rarely has space on the bench to use a mouse.
Login Dialog
When the Service Software application is invoked, by checking on the Service Software icon, the Login dialog box (Figure 1) will be displayed on the screen.
Nokia logo and application name
Application version
Copyright version Login box
Figure 1. Login dialog box
Nokia logo and application name bitmap () Displays Nokia logo and name of the application. Application version static text () Contains the name and version of the application. Copyright notice static text () Copyright is informed as: "Nokia Mobile Phones (c) 19951999. All Rights Reserved". Login Box edit box () The user Login ID edit box, where the user enters his faultlog user name. (See Faultlog User Guide) OK button (default key) The user name is stored in memory and the dialog box is closed. When the dialog box is closed, the application starts. Issue 1 06/01
Page 7 8
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Cancel button (ESC) The Dialog box is closed and application is started, but the Faultlog feature is disabled. Help button (F1) Activates the Windows Help application and displays context sensitive Help.
Main Window
When Wintesla opens the basic screen, product specific DLL's must be activated using mouse to select Product > Open and select RAE-3
Using Help
When DLL's are active, the menu bar contains several items, including help texts, as shown in Figure 2.
Figure 2. Menu bar
Instructions for service software use can be found in the help texts. Step by step instructions for complex operations like SW upgrades and tunings can be found in the end of this chapter.
Issue 1 06/01
Page 7 9
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
RAE-3 software upgrade guide
Equipment Setup instructions
1. Once a FPS8 box is used for the first time it has to be activated according to the instructions included in the FPS8 package. 2. Connect the box, cables and PC according to the drawing (see Figure 3)
7
2 8 5 3
6 4
1
Figure 3. Flashing setup
Item: 1 2 3 4 5 6 7 8 9
Service accessory:
Type
Product code:
Prommer FPS8 0750123 AC/DC Adapter FRIWO (Included in FPS8 sales pack) FW7207/6 0680032 D9 D9 Cable (Included in FPS8 sales pack) AXS4 0730090 Printer Cable (Included in FPS8 sales pack) 0730029 Service Battery BBL3B 0770206 Service Cable SCH8 0730137 Software protection key PKD1 0750018 Service SW diskette 3.5" for Wintesla 0774046 Service SW diskette 3.5" for RAE3 0775293
Page 7 10
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Setting up the PC
1. Install dongle drivers from CD-ROM (d:\32bit_Dongle_Driver\dk2wn32.exe directory) 2. Install WinTesla version (version 6.43 or later) from CD-ROM (d:\wintesla\wt_inst.exe directory) 3. Install the RAE3 DLL's from CD-ROM (d:\dlls\v30_80_00\Disk1\setup.exe directory)
Setting up BUS Configuration for WinTesla
Once Wintesla is first time used the Connection from PC to FPS8 has to be configured according to the instructions bellow (see Figure 4, Figure 5). 1. Start WinTesla software (c:\WinTesla\Stesla.exe)
Figure 4.
2. Set Bus Configuration for WinTesla according to Figure 2 below: Open Bus Configuration window by going "Configure" > "Buses..." Set COM port "1" , Hardware Type "COMBOX" and Media "MBUS" (see Figure 5 ).
Figure 5. Set Bus Configuration
Issue 1 06/01
Page 7 11
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Programming with WinTesla Interface
When the system has been setup, SW upgrade can be performed according to following instructions. 1. Insert BBL3B service battery. 2. Connect SCH8 cable from FPS8's "service cable" connector to N9210's bottom connector 3. 4. Connect power cable to FPS8's "service battery" connector. Start WinTesla software
5. Select Product > Open > RAE3 (or if WinTesla is already running and N9210 is on Press "F5" to initialize connection (see Figure 6)
Figure 6. Product Open
Page 7 12
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
6.
Select Dealer > Flash Phone...
Figure 7.
Wintesla user interface when the RAE3 is running and initialization has been successful.
Issue 1 06/01
Page 7 13
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
8. Flash Phone dialog opens. Select the correct language in the . . . . . . . . . . . . . . Market Area box.
Figure 8. Flash phone dialog
9.
Press "Flash" button (see Figure 8)
10. Once the program is prompting for restoring user data choose YES if you want to save user settings to file. (see Figure 9)
Figure 9. Saving user settings to file
Page 7 14
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
11. Programming starts ( takes about 6 minutes if the images already are stored in the Prommer memory) 12. Flash authority ID, Factory setup values and users settings (optional) are updated automatically.
Figure 10. Restoring Default User settings
13. After Flash programming complete message you can close the flash dialog (see Figure 11)
Figure 11. Flash programming completed
14.
Disconnect RAE3
Issue 1 06/01
Page 7 15
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Troubleshooting for the N9210 SW upgrade
If something went wrong during flashing: If you have a dead RAE3 1. Do not try to switch phone on
2. Use product> Open> RAE3. (Figure 12) Wintesla will prompt you " Did not find a phone in current connection! " Answer Yes.
Figure 12. Flash menu selection
3.
Then use Dealer > Flash Phone
Figure 13. Wintesla dialog when the RAE3 is not running
4. Because user settings cannot be read, Wintesla will prompt you " Failed to communicate with phone. Settings cannot be saved. Do you want to continue? " Answer Yes. Issue 1 06/01
Page 7 16
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Figure 14. Wintesla cannot read user settings
5. If Flash authority ID writing fails ( ) after flashing: . . . . . . . . FPS8 may not be activated,
Figure 15. Flash authority ID writing failed
Issue 1 06/01
Page 7 17
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Wintesla Tuning
Prior to any tuning the phone must be initialized: Connect the phone to a PC with a DAU9P cable Start WinteslaServiceSoftware and Select Product Open... RAE3 Select: Product Initialize Normal Mode Alt+p Alt+I F5 Alt+p
RF tuning after repairs
Different repairs require different tuning. In general it is necessary to determine in which section the repair was done to establish which tunings to perform. To determine if RF tuning is necessary after repair it is important that the functionality of the repaired circuit is understood well. In case the circuit is not fully understood it might be wise to play it safe and do RF tunings in accordance with the table below. In general repairs in the TX part will require tuning of "TX Power" and "TX I/Q" tuning. In general repairs in the RX part or PLL will always require "RX Calibration" and in some cases require AM Suppression tuning (Automatic) and RX Filter Calibration (Automatic). Other parts interfacing to TX, RX or PLL might require tuning, but common sense should be used. If it can be ruled out that a component change affects RF performance, e.g. the microphone B200, there is no need to do any RF tuning.
Page 7 18
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Equipment Setup for RF Tuning without Removing Covers
5
2
6
1 3 4
Figure 16. Tuning setup 1
Item: 1 2 3 4 5 6 7
Service accessory: Service car kit Service Battery Modular TAdapter Service MBUS Cable Software protection key Service SW CD for RAE3
Type HCL1 BBL3B DAU9S PKD1
Product code: 0770265 0770206 4626134 0730108 0750018 0774046 0775291
Service SW diskette 3.5" for Wintesla
Issue 1 06/01
Page 7 19
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
RX Calibration
The "RX calibration" is used to determine gain at different gainsettings for frontend and Hagar and needs to be done in both bands, but the calibration only have to be started once, it will automatically proceed to the PCN band after EGSM. Select: Tuning RX Calibration Alt+t r
947.06771MHz
Figure 17.
Note: Always use the latest Wintesla support DLLs Connect an external generator to the phones RF connector and set the generator as the window tells you. Click OK in the Wintesla window, now a new window pops up: Change the level on the generator as the window tells you. Click OK in the Wintesla window, now a new window pops up:
947.06771 MHz 86.00000
Figure 18.
Page 7 20
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Figure 19.
Difference between the gain steps should be 10dB1dB . Change the level and frequency on the generator as the window tells you. Click OK in the Wintesla window, now a new window pops up:
Figure 20.
Change the level and frequency on the generator as the window tells you. Click OK in the Wintesla window, now a new window pops up:
Issue 1 06/01
Page 7 21
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
.86.000000
Figure 21.
Change the level and frequency on the generator as the window tells you. Click OK in the Wintesla window, now a new window pops up:
Figure 22.
Difference between the gain steps should be 10dB1dB . Click Save in the Wintesla window. RX calibration is now completed. Issue 1 06/01
Page 7 22
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
RX Filter Calibration (Automatic)
This calibration is calibrating the Baseband filter inside Hagar, for this reason the calibration is not done in both bands. Select: Tuning Alt+t RX Measurements A window now popsup:
Figure 23.
In the "Select Function" frame select RX "Filter calibration (Automatic)". No external signal is needed for this, just click "Measure", wait a few seconds and then click "Save Defaults".
Issue 1 06/01
Page 7 23
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Figure 24.
RX filter calibration is now completed and the "RX Measurements" window can be closed by clicking "Close"
Page 7 24
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
RX AM Suppression (automatic)
This calibration is tuning the AM suppression performance of Hagar mixers and will have to be done in both bands. If flash or Hagar have been replaced or Full Factory settings have been performed RX AM Suppression must be done. EGSM Select: Product Band EGSM Select: Tuning RX Measurements A window now popsup: Alt+p b e Alt+t
Figure 25.
In the "Select Function" frame select RX "RX AM Suppression (Automatic)".
Issue 1 06/01
Page 7 25
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Click Measure, A window now popsup:
Figure 26.
Note: Always use the latest Wintesla support DLLs Connect an external generator to the antenna connector of the phone and set up the generator. Click OK in the Wintesla window, the RSSI value is updated in the RX Measurements window.
Figure 27.
Click "Save ". The "RX AM suppression tuning" is now completed in EGSM. Issue 1 06/01
Page 7 26
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
PCN Select: Product Band PCN Select: Tuning RX Measurements A window now popsup: Alt+p b p Alt+t
Figure 28.
In the "Select Function" frame select function "RX AM Suppression (Automatic)" Click Measure, A window now popsup:
Figure 29.
Issue 1 06/01
Page 7 27
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Note: Always use the latest Wintesla support DLLs Connect an external generator to the antenna connector of the phone and set up the generator. Click OK in the Wintesla window, the RSSI value is updated in the RX Measurements window.
Figure 30.
Click "Save ". The "RX AM suppression tuning" is now completed in PCN.
Page 7 28
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
TX Power Tuning
This tuning must be done in both bands.
TX Power tuning must be done with a peak power meter, Note: e.g. Rohde & Schwarz model NRVD with a Rohde & Schwarz Peak Power Sensor TDMA Model NRVZ31 and a suitable attenuator.
The use of power meter in GSM testers is likely to cause larger error than the use of a dedicated power meter and might cause the phone to be noncompliant with GSM specifications.
EGSM tuning
Select: Product Band EGSM Select: Testing RF Controls A window now popsup (Figure 31): Alt+p b e Alt+e r
Figure 31. RF Controls
Issue 1 06/01
Page 7 29
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Set Active unit to TX Set TX Data Type: to Rand Click Apply Click Close Select: Tuning TX Power... A window now popsup (Figure 32): Alt+t Alt+P
Figure 32.
Tune levels 19, 15, 5 and Base in accordance with the target values. Click calculate, check if the other levels match the targets, correct if necessary. Click Save when all values matches the targets.
Page 7 30
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
PCN tuning
Select: Product Band PCN Select: Testing RF Controls A window now popsup (Figure 33): Alt+p b p Alt+e r
Figure 33.
Set Active unit to TX Set TX Data Type: to Rand Click Apply Click Close Select: Tuning TX Power...
Alt+t Alt+P
Issue 1 06/01
Page 7 31
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
A window now popsup:
Figure 34.
Tune levels 15, 11, 0 and Base in accordance with the target values. Click calculate, check if the other levels match the targets, correct if necessary. Click Save when all values matches the targets.
Page 7 32
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
TX I/Q Tuning
This tuning must be done in both bands. Select: Product Band EGSM Select: Testing RF Controls A new pop up window appears Alt+p b e Alt+e r
Figure 35.
Set Active unit to TX Set TX Data Type: to Cont1 Click Apply Click Close and continue to next stage
Issue 1 06/01
Page 7 33
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Common tuning procedure Select: Tuning TX I/Q... A window now popsup (Figure 36) : Alt+t Alt+q
Figure 36.
The carrier and +67kHz signal should now be tuned to a minimum. (Figure 37) The buttons in the "TX I and Q DC Offset:" will change the level of the carrier. The buttons in the "Amplitude and Phase Difference:" window will change the level of the +67kHz signal. When minimum values are reached, click Save.
Figure 37.
Page 7 34
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Initial setup PCN Select: Product Band PCN Select: Testing RF Controls A window now popsup (Figure 38): Alt+p b p Alt+e r
Figure 38.
Set Active unit to TX Set TX Data Type: to Cont1 Click Apply Click Close and continue to next section
Issue 1 06/01
Page 7 35
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
IQ Tuning using Spectrum Analyzer
EGSM
Spectrum Analyzer Settings Use an appropriate attenuator 10 or 20dB insertion loss and set the Reference Level Offset according to insertion loss from the phone to the Spectrum Analyzer. Set the Spectrum Analyzer according to the following settings.
Parameter Center frequency Frequency span Resolution Bandwidth Video Bandwidth Sweep time Detector type reference level Marker 1 Marker 2 Marker 3 EGSM 902 MHz 300 kHz 3 kHz 3 kHz 3s Max. peak 35 dBm 902.06771 MHz 902 MHz 901.93229 MHz
Phone Settings Connect the phone to the computer and to the Spectrum Analyzer. Using WinTesla to select the following: Product Band EGSM This selects the EGSM band. Then select the following: Testing RF Controls...
Page 7 36
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
A window pops up (Figure 39):
Figure 39.
Set "TX Data Type" to "Cont1", press "Apply", then press "Close". The window closes. Select the following: Tuning Tx I/Q...
Issue 1 06/01
Page 7 37
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
A window pops up:
Figure 40.
This is the "Tx I/Q Tuning" window. Set the Power Level to "10". Then the Spectrum Analyzer shows a plot like this (Figure 41):
Figure 41.
Marker 1 shows the wanted signal. Marker 2 and marker 3 show the unwanted signals.
Page 7 38
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
In the "Tx I/Q Tuning" window use "TX I DC Offset" and "TX Q DC Offset" to adjust the spurious at 902.0MHz (Marker 2) to the minimum level.
Figure 42.
Then the Spectrum Analyzer shows a plot like this (Figure 43):
Figure 43.
In the "Tx I/Q Tuning" window use "Amplitude Difference" and "Phase Difference" to adjust the spurious at 901.93229 MHz (Marker 3) to the minimum level.
Issue 1 06/01
Page 7 39
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Figure 44.
Then the Spectrum Analyzer shows a plot like this (Figure 45):
Figure 45.
In the "Tx I/Q Tuning" window press "Save" and the optimal values are stored in the phone. The window closes.
Note: The optimal values for "TX I and Q Offset" and "Amplitude and Phase Difference" vary from phone to phone.
Page 7 40
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
PCN
Spectrum Analyzer Settings Use an appropriate attenuator 10 or 20dB insertion loss and set the Reference Level Offset according to insertion loss from the phone to the Spectrum Analyzer. Set the Spectrum Analyzer according to the following settings.
Parameter Center frequency Frequency span Resolution Bandwidth Video Bandwidth Sweep time Detector type reference level Marker 1 Marker 2 Marker 3 PCN 1747.8 MHz 300 kHz 3 kHz 3 kHz 3s Max. peak 35 dBm 1747.73229 MHz 1747.8 MHz 1747.86771 MHz
Phone Settings Connect the phone to the computer and to the Spectrum Analyzer. Using WinTesla to select the following: Product Band PCN This activates the PCN band. Then select the following: Testing RF Controls...
Issue 1 06/01
Page 7 41
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
A window pops up:
Figure 46.
Set "TX Data Type" to "Cont1", press "Apply", then press "Close". The window closes. Select the following: Tuning Tx I/Q... A window pops up:
Figure 47.
Select "EEPROM Values" and a new window pops up: Issue 1 06/01
Page 7 42
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Figure 48.
This is the "Tx I/Q Tuning" window. Set the Power Level to "5". Then the Spectrum Analyzer shows a plot like this (Figure 49):
Figure 49.
Issue 1 06/01
Page 7 43
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
In the "Tx I/Q Tuning" window use "TX I DC Offset" and "TX Q DC Offset" to adjust the spurious at 1747.8MHz (Marker 2) to the minimum level.
Figure 50.
Then the Spectrum Analyzer shows a plot like this (Figure 51):
Figure 51.
Marker 1 shows the wanted signal. Marker 2 and marker 3 show the unwanted signals.
Page 7 44
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
In the "Tx I/Q Tuning" window use "Amplitude Difference" and "Phase Difference" to adjust the spurious at 1747.86771MHz (Marker 3) to the minimum level.
Figure 52.
Then the Spectrum Analyzer shows a plot like this:
Figure 53.
In the "Tx I/Q Tuning" window press "Save" and the optimal values are stored in the phone. The window closes. Note: The optimal values for "TX I and Q Offset" and "Amplitude and Phase Difference" vary from phone to phone.
Issue 1 06/01
Page 7 45
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
Energy Management (EM) Calibration
Equipment Setup for Energy Management calibration
NOTE: EM values can not be tuned in module jig MJS14
1.
4
5
2 6. and 7. 3
Figure 54. Tuning setup 2
Item: 1 2 3 4 5 6 7
Service accessory: Dummy Service Battery DC Cable Service MBUS Cable Calibration unit Software protection key Service SW CD for RAE3
Type BBL3B SCB3 DAU9C JBE2 PKD1
Product code: 0770206 0730114 0730138 0775290 0750018 0774046 0775291
Service SW diskette 3.5" for Wintesla
Page 7 46
Issue 1 06/01
PAMS Technical Documentation
RAE-3 7. Service Software Instructions
Energy Management Calibration procedure
NOTE: This can not be done in module jig MJS14. EM calibration is possible only when phone is completely assembled. Connect DAU-9C cable and BBL-3B battery to RAE2N phone Connect BBL-3B to the calibration unit JBE-2 and DC cable SCB-3 between phone and calibration unit. Connect JBE-2 to laboratory power supply which is adjusted to 8.0V Start Wintesla service SW Select Tuning > Energy Management Calibration Run calibrations separately or all at once as described in the following list. Connect 10.5V to the calibration unit JBE-2 as prompted by service SW. Select calibrations: Select 1.Run Battery & charger default values checkbox Select 2.Battery voltage checkbox Select 3.Charger voltage checkbox Select 4.Battery size checkbox Select 5.Battery temperature checkbox Select 6.Charge current Select Save without confirmation, if you don't want confirm all the selected calibration values before saving Run calibrations by pressing Run button Set supply voltage back to 8.0 V
Issue 1 06/01
Page 7 47
RAE-3 7. Service Software Instructions
PAMS Technical Documentation
This page intentionally left blank.
Page 7 48
Issue 1 06/01