Text preview for : _dry_iron_©_.pdf part of Philips GC137 Service Manual ser. Diva - pag. 3
Back to : _dry_iron_©_.pdf | Home
Dry Iron, Diva GC 137
Philips Domestic Appliances and Personal Care
Service manual 4322 277 00480 is herewith cancelled.
Service Manual
PRODUCT INFORMATION Features - Colour red - Aluminium soleplate - Pilot lamp - Full length button groove - Integrated cord winder Soleplate The Aluminium soleplate used is smooth and corrosion free which treats fabrics gently. TECHNICAL INFORMATION Voltage/frequency Power consumption : 100 V, 110-127 V, 220-240 V, 50-60 Hz : 900 W at 100 V 950-1100 W at 220-240 V 750-1000 W at 110-127 V
This product meets the requirements regarding interference suppression on radio and TV.
Published by Philips Domestic Appliances and Personal Care
Printed in the Netherlands
© Copyright reserved
Subject to modification
4322 277 00729 02/01
DISASSEMBLY ADVICE DRY IRON DIAL 1 RATTLE SPRING 6
PARTS LIST DRY IRON
Pos 1. 2. 3. 4.
Description Dial printed (Eng/Fre/Spa) Inlay Swivel Cord set 220-240 V / 950-1100 W Cord set 100 V / 900 W Cord set 110 V / 750 W Lamp Rattle spring Handle Thermostat bush Soleplate Cover Insulator ring Soleplate assy 220-240 V / 950-1100 W Soleplate assy 100 V / 900 W Soleplate assy 110 V / 750 W
Consist of
Service code 4239 021 05120 4239 026 06960 4239 026 06980 4239 000 07140 4239 000 07930 4239 000 07150 4239 021 03880 4239 014 52700 9965 000 08985 4239 026 06220 4239 015 33490 4239 015 70150 4239 021 05660 4239 021 06440 4239 021 05600
INLAY 2 SWIVEL 3
Remove Screws A1 and A2
5. 6. 7. 8. 9. 10. 11.
101, 102
103
CORD SET 4 LAMP 5
Remove Remove Remove Remove Remove Remove Dial 1 Rattle spring 6 Screws A1 and A2 Inlay 2 Swivel 3 Screws B1 and B2
NOTES : After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as laid down and officially established at this moment.
HANDLE 7 (101, 102) THERMOSTAT BUSH 8
Remove Remove Remove Remove Remove Remove Remove Remove Remove Dial 1 Rattle spring 6 Screws A1 and A2 Inlay 2 Swivel 3 Screws B1 and B2 Cord set 4 Lamp 5 Screw C
ADJUSTMENTS AND CONTROLS Thermostat, 103 The thermostat, fitted to soleplate 11 has already been adjusted by the supplier and secured by glue. To avoid disfunction of the iron, NEVER readjust the thermostat. For standardisation reasons : * Silverstone soleplate will be used for GC 147, GC 146 and GC 141. * Aluminium soleplate will be used for GC 130, GC 135 and GC 137. * GC 130 and GC 141 will not have the pilot lamp indication. Parts, with numbers from 100 and higher cannot be ordered separately.
SOLEPLATE COVER 9 INSULATOR SUPPORT 10
Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Remove Dial 1 Rattle spring 6 Screws A1 and A2 Inlay 2 Swivel 3 Screws B1 and B2 Cord set 4 Lamp 5 Screw C Handle 7 Thermostat bush 8 Screw D Screws E1 and E2
EXPLODED VIEW DRY IRON
A1 A2 3
4 2
B1
6
B2
102 7 101
1 E1 8 C D 5 E2
9 103
10
11
Screws : A1, A2 B1, B2 C D E1, E2
d 2.5 3.5 3.5 4 4.0
x x x x x x
l 9.0 mm 12.0 mm 10.0 mm (with washer) 9.0 mm (with washer) 16.0 mm