Text preview for : HiPath_3300_3500_V3_Vital_Stats.pdf part of siemens hipath3000 manual



Back to : HiPath_3300_3500_V3_Vital | Home

s
Reseller Learning Zone
Application No: 2221 - HiPath 3300 & 3500 V3.0 Vital Statistics

November 2002

Prepared by Reseller Sales Support Team

Reseller Learning Zone

s Application No: 2221 HiPath 3300 & 3500 V3.0 Vital Statistics
Detailed below is information on the physical build and specifications for Version 3 of the HiPath 3300 and 3500 rack mounted voice servers which should be useful when responding to tenders etc. Maximum Capacities The following figures exclude extensions connected via adapters. HiPath 3300 Maximum corded (TDM) extensions Maximum cordless (TDM) extensions Maximum IP extensions Maximum trunks HiPath 3500 Maximum corded (TDM) extensions Maximum cordless (TDM) extensions Maximum trunks Maximum IP extensions 28 16 96 16 52 32 60 (one PRI card only) 192

NB 1 The combined maximum trunk and extension capacities will depend on individual configurations. NB 2 The combined maximum TDM corded, cordless and IP extension capacities will depend on individual configurations. NB 3 ISDN devices connected via S0 Bus to be included in extension capacities. Control Unit Details Number of universal card slots Cabinet Size (H * W * D) Cabinet Weight HiPath 3300 HiPath 3500 HiPath 3300 HiPath 3500 HiPath 3300 2 HiPath 3500 6 89mm*440mm*380mm (2U) 155mm*440mm*380mm (4U) 6KG (fully configured) 8 KG (fully configured)

NB Systems are designed to be mounted in a standard 19-inch rack.

Reseller Learning Zone

s Application No: 2221 HiPath 3300 & 3500 V3.0 Vital Statistics
Main Distribution Frames (MDF) All trunk and extensions pre-terminated on integrated RJ45 sockets. Processor Board Details V24 Ports System memory System CPU Maintenance modems Operating Environment Temperature Relative humidity Absolute humidity Heat emission +5 to +40 degrees C 5 to 80% 2 to 25g H20/m3 HiPath 3300 180KJ/h HiPath 3500 360KJ/h 1 (9 way) 16Mbit Memory Module Motorola Coldfire Integrated digital (ISDN) modem Optional V32 bis 14.4Kbits analogue modem

NB Systems uses fan assisted cooling. Power Requirements Rated input voltage Rated frequency Power consumption 100/240V AC. 50/60 Hz. HiPath 3300 90 watts HiPath 3500 180 watts

A clean dedicated mains supply is required terminating on a 13 Amp socket (in accordance with IEEE regulations). Mains Plugs should be fitted with a 3 Amp fuse.

Reseller Learning Zone

s Application No: 2221 HiPath 3300 & 3500 V3.0 Vital Statistics
UPS Battery Specifications Battery size (H * W * D) 155mm*440mm*380mm (4U) Battery capacity 7 Ampere hour Output voltage 48 Volts Battery back up times HiPath 3300 4 hours 40 minutes (average config) HiPath 3500 2 hours 20 minutes (average config) Rack Earthing: Earthing of the 19-inch rack must be in accordance with the latest edition of IEE regulations. Cable Specifications and Distances for TDM devices Standard 0.5mm twisted pair cable. Single pair required by both analogue and digital (optiPoint 500) telephones. Maximum distance optiPoint 500 - 500 metres (extended to 1000 metres with plug in PSU). Maximum distance optiPoint 500 Master to optiPoint 500 / analogue slave - 100 metres. Maximum distance analogue device - 1000 metres. Maximum distance S0 Bus up to 150 metres point to multipoint. 600 metres point to point. Maximum distance DECT base station - 1000 metres. Trunk Specifications
HiPath 3300 Digital: BRI (ISDN 2e) Analogue: Loop Calling Unguarded Clear HiPath 3500 Digital: BRI (ISDN 2e). PRI (ISDN 30e) Analogue: Loop Calling Unguarded Clear

Extension Specifications
Digital: 2B + D using Siemens UPOE protocol. Analogue: DTMF / Loop Disconnect. Timed Break Recall (TBR).

Tie Line Specifications
Digital: QSIG Analogue : CE Compliance: Electromagnetic Compatibility DECT Safety - International Siemens CorNet N Not available EN 50082-1 ETS 300, 329. TBR 06 IEC 60950 + A1 + A2 + A3 + A4