Subject: Unstable Display Symptom: (13)
Date: May 29, 1996
The unit exhibits an unstable display.
Solution:
Perform the following: 1.) Cut a pattern between Q955 C, E and the negative side of C963. 2.) Connect the collector of Q956 to the negative side of C963 via a jumper wire. 3.) Change the location of the 1K resistor lead mounted to the emitter of Q956 (foil side of the board) to the emitter of Q955 (See diagram below).