Steam Iron HI 272 HI 274

Philips Domestic Appliances and Personal Care

PRODUCT INFORMATION Features Pilot light Integrated cord winder Spray Shot of steam Self-clean Length cord set 2.5 m Soleplate coated Soleplate stainless steel Voltage / frequency HI 272 x x x x x x x : 220 - 240 V, 50-60 Hz 110 - 127 V, 50-60 Hz : 220 - 240 V 1325 Watts 110 - 127 V 1200 Watts HI 274 x x x x x x x

Power consumption

Soleplate temperature with dial at max. position : 215 ± 25 °C

Self-clean function : The self-clean function is operated by the steam dial. When this dial is turned to the correct position, a sudden flow of cold water is released from the tank into the heated soleplate. This thermal shock will cause scale particles to break loose from the steam chamber. These particles are then flushed out through the steam vents by the water.

This product meets the requirements regarding interference suppression on radio and TV.

Published by Philips Domestic Appliances and Personal Care

Printed in the Netherlands

© Copyright reserved

Subject to modification

4822 729 21819 97/04
PCS 88 665

DISASSEMBLY ADVICE BACKPLATE 3 CORD SET 4 SWIVEL 5
remove SCREW A 2x remove BACKPLATE 3

REASSEMBLY ADVICE + PARTS LIST COVER 18 TYPEPLATE 19 SOLEPLATE 21 THERMOSTAT 20
remove SCREW A 2x remove BACKPLATE 3 remove SCREWS cordset/ pilot light/pcb remove SCREW B lx remove INLAY 6 remove SCREW 22 remove DIAL HOLDER 10 remove PUMP/SPRAY UNIT 14 remove SCREW D 3x Replacement Thermostat see fig.1-4 REASSEMBLY ADVICE When reassembling the iron, make sure that : * Thermostat bush ( 17 ) is set to the position illustrated in fig A. * Dial Link ( 12 ) and Dial Thermostat 9 are set to the positions, illustrated in fig B.

INLAY/LAMPCOVER 6 PILOT LIGHT 7 DIAL THERMOSTAT 9 RATTLE SPRING 11 DIAL LINK 12
turn DIAL 9 on max position remove SCREW A 2x remove BACKPLATE 3 remove SCREWS cordset/ pilot light remove SCREW B lx remove INLAY 6

PARTS LIST Pos 1 2 3 4 Description dosing unit cord clip cord winder/backplate cord set Euro plug cord set UK plug cord set UL plug cord set "China plug" swivel inlay + lampcover 109 pilot light 220 - 240 V pilot light 110 - 127 V dial thermostat dial holder + spring 11 rattle spring dial link spray unit pump/spray unit incl. item 13 + 106 handle unprinted tank + stopper 102/H1272 and sealing 103 thermostat bush cover type plate unprinted thermostat sole plate 220 - 240 V incl. item 20 + 104 sole plate 110 - 127 V incl. item 20 + 104 long tapping screw kit sealings item 101 - 107 Service Code 4822 360 10142 4822 401 11193 4822 441 12002 4822 321 10951 4822 321 10952 4822 321 10947 4822 321 11317 4822 325 80505 4822 310 11004 4822 134 20334 4822 134 20335 4822 412 40262 4822 256 10379 4822 492 32876 4822 535 93498 4822 360 60291 4822 360 10321 4822 498 10657 4822 310 11006 4822 532 61258 4822 442 00973 4822 452 10337 4822 282 30229 4822 259 10263 4822 259 10262 4822 502 21315 4822 310 11007

DIAL HOLDER 10 SPRAY UNIT 13 PUMP/SPRAY UNIT 14
remove SCREW A 2x remove BACKPLATE 3 remove SCREWS cordset/ pilot light remove SCREW B lx remove INLAY 6 remove SCREW 22

5 6 7 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

HANDLE 15 WATERTANK 16
remove SCREW A 2x remove BACKPLATE 3 remove SCREWS cordset/ pilot light/pcb remove SCREW B lx remove INLAY 6 remove SCREW 22 remove DIAL HOLDER 10 remove PUMP/SPRAY UNIT 14 remove SCREW C 2x

PCS 88 666

NOTES 1) For standardisation reasons : * only the coated soleplate will be supplied for those types, which are suitable for 110 - 127 V. * only the stainless steel sole plate wil be supplied for those types, which are suitable for 220 - 240 V. * no info about type number and voltage has been stamped onto the typeplate. When replacing the type plate, engrave at least type number and voltage into the type plate with a sharp object. * tank 16 has been provided with the tank valve 101 of the dripstop version of the HI 282/284 resp. HI 292/294. The black rubber stopper 102, belonging to the tank of the H1272/274, has been included as a spare part. When replacing the water tank, always provide the tank with the rubber stopper 102. 2) Parts, with numbers from 100 and higher, cannot be ordered separately. 3) After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as laid down and officialy established at this moment.

ADJUSTMENT AND CONTROLS Thermostat 20 Thermostat 20, fitted to the sole plate 21 has already been adjusted by the supplier and secured by glue. To avoid malfunction of the iron, NEVER readjust the thermostat. Adjustment Thermostat 20, supplied as a spare part. Connect the connecting strips to an Ohm meter. Set the thermostat stopper to the position as indicated in fig. 1. Turn the adjusting screw ( R ) clockwise or anti-clockwise until the Ohm meter indicates " 0 ". ( the contacts are closed ). Then turn the adjusting screw clockwise until the Ohm meter indicates and the contacts have only just been opened. You hear a " click ". While loosely turning the thermostat stopper, check if the thermostat switches in the position as indicated in fig. 1. Secure the adjusting screw by glue. After adjusting the thermostat, always check the temperature of the soleplate, with the dial set to MAX. pos. ( 215 ± 25 °C ). For location of the test point, see fig. 2. The temperature must be measured, after the iron has been connected to the mains for at least 15 min. The max. temperature shall not be higher than 240 °C.

2
N FUSE RESISTOR INPUT LAMP L E HI 272, HI 274 HEATING UNIT

Testpoint

THERMOSTAT