Text preview for : MANUAL SERVICE MX5203MS 14.pdf part of POLYTRON ( INDONESIA ) MX5203MS It used STV2286H , AN5891K , TDA8174 , STB9NK70Z-1 Complete Service Manual in RAR file type.sent by [email protected]
Back to : MX5203MS Service Manual | Home
Service Manual BML Myanmar
Adjust R & G DC, to get standard value :
PT.Hartono Istana Teknologi
x = 264 ± 7 } y = 256 ± 7 Y = 1.8 s/d 5
xy 5
Minolta CA-100
-
Press menu button to save data Adjustment. Change its probe to the white one. Adjust R gain, G Gain to get standard value :
x = 264 ± 5 } y = 266 ± 5
Minolta CA-100+
-
Press menu button to save data Adjustment. Check again if low bright value has non standard value. Repeate same steps to make correction. Check High Bright once again and make correction if its value isn't conforming, until we got Low Bright and High Bright value according by standard value.
2. APR Adjustment : - Acces to service mode. - Set APR to position : - 20" = 07 (Domestic & Export) - 21" & 21" RF = 07 (Domestic) - 21" & 21" RF = 15 (Export) - Press menu button to save data Adjustment. 3. Normalisation Setting (memory setting) : - Brightness = 60 - Contrast = 100 - Color = 60 - Sharpness = 75
- Tint - PNR - Pic Improve
= 00 = OFF = ON
13