Text preview for : Stream_Iron_®_.pdf part of Philips Domestic App. HI555, HI556, HI565, HI566 Service Manual Domestic Appliances and Personal Care 1.200/1.450W [Ver.2] - pag. 7



Back to : Stream_Iron_®_.pdf | Home

Steam Iron

Service Service Service
Philips Domestic Appliances and Personal Care

HI555 HI556 HI565 HI566

Service manual 4822 729 22167 is herewith cancelled

Service Manual
PRODUCT INFORMATION Features Pilot light Integrated cord winder Spray Variable steam Turbo steam Shot of steam Vertical steam Self clean Enght cord set 2.5 m Anti-drip function Automatic shut-off Anodised soleplate Carry case Voltage / Frequency Power consumption HI555 x x x x x x x x x x HI556 x x x x x x x x x x x HI565 x x x x x x x x x x x x HI566 x x x x x x x x x x x x x Turbo steam function : The steam output of the variable steam function depends upon the position of the slide knob. When set to position 6 the steam output is 12 gr/min. This might be not sufficient. In that case the turbo button has to be pushed down for max 10 sec. Due to this operation the steam output will increase to 30 gr/imn. Vertical steam : When the iron is kept in a vertical position, the s.o.s. button can be used to iron hanging fabrics as curtains. Self-clean function : When the self-clean button is pushed down, a sudden flow of water is released from the tank into the heated sole plate. This thermal shock will cause scale particles come loose from the steam chamber. These particles are then flushed out through the steam vents by the water. Anti-drip : Water is only released through the tank valve into the steam chamber if the sole plate temperature is high enough to evaporate all water. If the temperature is not hot enough the tank valve is closed by means of the bi-metal disc. Auto shut-off : A relay in the electronic module interrupts the power to the heating element when the iron has been motionless : - for 30 seconds in horizontal position. - for 8 minutes in vertical position. The red " Auto-off " pilot light starts blinking, a sound signal is heard too. When the iron is moved again, it's automatically switched on again. When the iron is moved again, it's automatically switches on again. N.B. When the iron is plugged in in a horizontal position, it will not be switched off during the first 2 minutes to ensure that it heats up properly. Real-off function : The movement of the thermostat's bi-metal is limited in downward direction thus will prevent the thermostat contacts from closing at room temperature at MIN setting.
Printed in Hong Kong
© Copyright

: 100V, 110-127V, 220-240V 50-60Hz : 100V, 110-127V, 220-240V, 1200W at 100V 1300W at 120V 1450W at 220V

Soleplate temperature : 215°±25°C Steam output : Varible steam output max. 12gr/min when : - slide is set to position 6 - temperature dial is set to position MAX. Turbo steam output : Always to be used in combination with the variable steam slide, increase the steam output with max. 18gr/min to a total of 30gr/min. Shot of steam : 60gr/min. This product meets the requirement regarding interference suppression on radio and TV.

Published by Philips Domestic Appliances and Personal Care

reserved

Subject to modification

4322 277 00258 02/00 Ver.2

DISASSEMBLY ADVICE
POWER PACK:

PART LIST
Pos 30.0

POWER PACK + STAND AND CARRY CASE
Service code 4239 020 97120 4239 020 95570 4239 020 98570 4822 321 11377 4822 321 11378 4822 321 11379 4822 321 11381 4239 025 90080 4239 020 69260 9965 000 00171 4239 020 95590 4239 025 97620 4239 022 52860 9965 000 00172 4239 020 95450 4239 020 95460 9965 000 00173

CORDSET 30.1 SWIVEL 30.2 CONTACT HOUSING 30.3 COMPONENTS SLIDE 30.4
removes SCREW I

30.1

30.2 30.3 30.4 31.0 31.1 31.2 31.3 32.0 32.1

STAND:

Description Power pack complete, with UK cordset Power pack complete, with EU cordset Power pack complete, with flat pin cordset Cordset China Cordset UK Cordset EU Cordset flat pin plug Swivel Contact housing Components slide Stand complete Support bar stand Clamp of stand Components 3 pos.switch Carry case complete HI556 Carry case complete HI566 Set of latches + spring

SUPPORT BAR 31.1 CLAMP OF STAND 31.2 COMPONENTS 3 POS. SWITCH 31.3
removes SCREW J CARRY CASE:

SET OF LATCHES + SPRINGS 32.1
removes SCREW K

K

EXPLODED VIEW POWER PACK AND STAND

Screws : I J K

d M4 7N 2,5

x x x x

DISASSEMBLY ADVICE
DIAL 1 RATTLE SPRING 2
remove remove remove remove

SLIDE UNIT 13 NEEDLE 14
SCREW C 1x BACK PLATE 4 INLAY 6 SCREW A 2x

Replacement Thermostat see fig. 1-4

HANDLE 15 SPRAY PUMP 16 BACK PLATE 4
remove SCREW C1x remove BACK PLATE 4

S.O.S.PUMP 17 TANK 18 SELF CLEAN BUTTONS 19 SEALINGS 22
remove SCREW C 1x remove BACK PLATE 4 remove INLAY 6 removeSCREW A 2x remove DIAL 1 remove SCREWS cord clamping 2x remove SCREW B 3x remove SCREW AI 2x remove HANDLE 15

INLAY 6 OPERATION KNOBS 7 DOOR 8 DOOR HOLDER/ DEAIR. BUSH 9 SPRAY UNIT 10 PILOT LIGHT 11 PCB 12
remove SCREW C remove BACK PLATE 4 remove INLAY 6

THERMOSTAT 20 THERMOSTAT PIN 21 SEALINGS 22 COVER 23 TYPE PLATE 24 SOLE PLATE 25 ANTI-DRIP VALVE 26
SCREW C 1x BACK PLATE 4 INLAY 6 SCREW A 2x DIAL 1 SCREWS cord clamping cord set pilot light / pcb remove SCREW B 3x remove SCREW A1 2x remove HANDLE 15 remove SCREW F 3x remove remove remove remove remove remove

PARTS LIST
Pos 1 2 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Description Dial HI515/525 (Blue) Dial HI535/545 (Green) Rattle spring Black plate 220-240V Black plate 100-127V Inlay HI555-HI556 Inlay HI565-HI566 Set operation knobs HI515/HI525 ( Blue) Set operation knobs HI535/HI545 (Green) Door Door holder / deairing bush Spray unit Pilot light 100-240V PCB module 100-127 V PCB module 220-240 V Slide unit (Blue) Needle set Handle unprinted Spray pump set S.O.S. pump set Water tank set (blue) Water tank set (green) Self clean button set (Blue) Self clean button set (green) Thermostat Thermostat pin Sealing set Soleplate + thermostat 100V Soleplate + thermostat 110-127V Soleplate + thermostat 220-240V Anit drip value set Cover + Typeplate Consists of 101,102,103 101,102,103 Service code 4822 310 11328 4822 310 11329 4822 310 11021 4239 020 95560 4239 020 98560 4239 020 93410 4239 020 93520 4822 310 11335 4822 310 11336 4822 443 11191 4822 310 11026 4822 360 10441 4822 134 10094 4239 020 86770 4239 020 86780 4822 310 11337 9965 000 00170 4822 498 10732 4822 310 11339 4822 310 11341 4822 310 11342 4822 310 11343 4822 310 11344 4822 310 11345 4822 282 10315 4822 535 10469 4822 310 11034 4822 259 10327 4822 259 10329 4822 259 10328 4822 310 11035 4239 022 52850

104,105 104,105 105,106,107 105,106,107 108,109

11 11

110,111,105 112, 113, 114, 115, 116 10,117,118,119,120 117,118,120,121,122 108,109,123,124,125,126 108,109,123,124,125,126 124,125 124,125

112

11 115

114

116 109 108

126,127,128,129

24 25 DFU: Note:

126,130 131,132

119 10

121 1

From week 0005 onward, cover (item 131) and typeplate ( item 132) have been modified. The modified parts are not interchangeable with the orginal parts. In case the item 131 or item 132 need to be replaced, both item have to be replaced together under code number 4239 022 52850 ( item 25).

HI555 ~ HI556

Screws : d x A, A1 M2.6 x B 6N x C M3 x D M3.5 x E M3.5 x F M4 x G 7N x H 8N x

1 9 1 1 6 7 8 3 1

HI565 ~ HI566

EXPLODED VIEW

104 2 105 107 8 A1 111 110 106 112 113 115 114 116 109 108 B A A1

103

102 101

12

C

4 B

124 125

15

117 118 120

E 11

119 10 121 122 123 126 G 131
d M2.6 6N M3 M3.5 M3.5 M4 7N 8N x x x x x x x x x 1 9.5 13 13 6 7 8 30 13
Part modified since week 0005

F

F

132

127 128 129 130

H H

23 21 20

Part modified since week 0005

IMPORTANT + ADJUSTMENT AND CONTROLS
IMPORTANT Due to the high wattage of the iron, only the specified cordsets must be used. NOTES : 1) For standardisation reasons : Dial Rattle spring Type plate : With English / Spanish text only. : 5 pieces will be supplied when ordered : No info about the type number and voltage have been stamped onto the typeplate. When replacing the type plate, engrave at least type number and voltage onto the type plate with a sharp object. : with blue color only.

Slide unit 13

2) Parts, with numbers from 100 and higher, cannot be ordered separately. 3) After the product has been repaired, it should function properly and has to meet the safety requirements and legal regulations as laid down and officially established at this moment. ADJUSTMENT AND CONTROLS Thermostat : Thermostat 20, fitted to the solplate 25 has already been adjusted by the supplier and secured by glue. To avoid mal-function of the iron, NEVER re-adjust the thermostat. Adjustment thermostat 20, supplied as a spare part. N.B. Before starting to adjust the thermostat, make sure that a gap exists between the lower tip of the ceramic insulating pin and the real-off bracket. See fig. 1. Connect the connecting strips to an Ohm-meter. Set the thermostat stopper to the position as indicated in fig. 2. Turn the adjusting screw (R) clockwise or anti-clockwise until the Ohm-meter indicates"0". (The contacts closed) Then turn the adjusting screw clockwise until the Ohm-meter indicates and the contacts have only just been opened. You hear a "click". While loosely turning the thermostat stopper, check if the thermostat switches in the position as indicated in fig. 2. After the thermostat has been adjusted, adjust the real-off bracket. Set the thermostat stopper in the position shown in fig. 3. The thermostat contacts are closed. (Ohm-meter indicates "0") Turn the set-screw S clockwise until the contacts have only just been opened. The Ohm-meter indicates . Secure the adjusting screws with a glue. After adjusting the thermostat, always check the temperature of the soleplate, with the dial set to MAX. position (215° ±25°C) For location of testing point, see fig. 4. The temperature must be measured, after the iron has been connected to the mains for at least 15 min. The max. temperature shall not be higher than 240°C.