Service Technical Information
MODEL NO.
CSD-SL20
SUBJECT
Tape unit does not run
REF.No. :G -A0 - 049 - E0 DATE :10. JUL. 2000
On the model concerned, tape unit does not run or fails in playback operation. Analyze the symptom and take the following countermeasure. The motor fails to run due to open status of a Q415 (CASS.MOTOR ON/OFF SW/DTC124 -X5) on P.W.B.MAIN. Replace Q415 with a new part and take the following countermeasure: 1) Cut the Line between Q415 collector and Q416 base on P.W.B. MAIN.
CUT LINE
Q415
Pattern side 2) Solder 2.2K , 1/8W resistor.
Parts side
R452 1k Q 416 2SA1296GR CN404
4 3 2 1 4 3 2 1
Add Resistor 2.2K
PN404
1 ) CUT L I E N
R450 470k
- + DECK MOTOR
Q 415 DTC124-X5 MOTOR LEAF SW
2 ) Add R es is to r 2 .2K