REF.No. :G - A1 - 006 - E0 DATE :28. MAY. 2001

On the above models, touch sensor on the " MD EDIT STAGE " or " SOUND CONTROL STAGE " of the " Magical change panel " may become inoperative causing the " Magical change panel " not rotating. In such a case, take the following countermeasure. 1) Check the conduction between S816 and R817 on the FACE-C C.B of magical change panel to see if any brakage exists. And, if no conduct is confirmed, then connect them using a wire.(length is around 2cm) 2) Fix the wire by a adhesive cloth.

S816

R817

Add Wire

FACE-C C.B

Secure the wire with CLOTH

G -

R -

Code No. -

Access Code -

Modified Ser. No. S 14 ~

Parts Schedule -