Text preview for : 4725.pdf part of Braun Oral Line Outline and explosion device, service manual and catalog



Back to : Braun_Oral_Line_Carioquen | Home

Service Documentation Braun Plak Control Travel

Market Release 8/92

D 5525 T D 5525 TS

4725

4725

BINC Rev: 7/96 BAG Rev: 9/92

Service Documentation
Exploded Drawing 4725

4725 - 2

BINC Rev: 8/98 BAG Rev: 5/94

Service Documentation
Spare Parts List 4725 Part Description Part Number

Pos. No.
D 5525 T 1 2 2 3 4 5 D 5525 TS 11 11 12

Protective cap Handle Handle with timer Switching plate Trickle charger Brush case Ring for power cord

4725626 4726630 4730631 4726860 4725623 4725625 4725029

Handle Handle with timer Protective cap

4730630 4730631 4725630

4725 - 3

BINC Rev: 7/96 BAG Rev: 9/93

Service Documentation
Service Information 4725 Rechargeable unit Plastic, heat sealed, 2.4 V-DC-motor. The transmission of power follows by way of gear train with excenter to the shaft of the brush. 2 built-in batteries, which can be recharged by inductive continuous operating charger (without contact). It compensates the loss of charge in the daily use. Continuous charging. No danger of overloading. Signal by a green LED (light emitting diode). Line voltage: 110 - 240 V/50-60 c/s without selecting switch. Power input approx. 1 watt. Multituft, case for brushes Oscillating brush movements approx. 70° Magnetic switch (reed switch), watertight. Pressure switch, watertight. Length without brush 18.5 cm, diameter 3.2 cm. Height 3.8 cm, length 8 cm, width 3.2 cm. approx. 45 minutes when unit was fully charged. is equipped with an optical 2-minute timer, indicated by a red LED.

Technical Data Appliance: Power supply: Charger, continuous operating: Brushes: Brush function: Angle of oscillation: Switch D 50: Switch D 50 S: Dimensions of the unit: Dimensions of the charger: Operating time: Plak control timer only:

Cell-Pack Recycling of Braun-Plak Control At the end of the time-of-use of this product, for environmental protection, the nickel/cadmium (NC)-cell pack must be correctly recycled. For this purpose, the following steps are necessary: · · · · Put appliance into the trickle charger and break-off lower cap (see illustration). By applying pressure to the motor shaft, push cell pack with motor assembly out of housing and tear-off both thin connecting wires. Break-off cell pack with PCB from motor and remove the remaining part of the PCB from the cell pack. Remove cell pack out of plastic tube and dispose cells according to local laws or applicable environmental regulations for correct material separation and recycling. The cells must never be thrown into fire or flame.

4725 - 4