Text preview for : hot_pot_®_.pdf part of Philips HD 4770 Service Manual Hot Pot 1000W [12/98] Ver. 1 - pag. 3



Back to : hot_pot_®_.pdf | Home

HOT POT

Service Service Service
Philips Domestic Appliances and Personal Care

HD4770

Service Manual
PRODUCT INFORMATION Voltage Frequency Power consumption Capacity : 220-240V : 50-60 Hz : 1000 W at Boiling mode 50 W at keep warm mode : 3.0 Liters Auto keep warm : The keep warm temperature is preset at 79°C to 85°C, which is controlled by thermal reed switch (item 6). Reboil : When activate the REBOIL switch, water will be heated up from preset keep warm temperature to boiling temperature in five minutes maximum. Empty boil protection : The circuit of the appliance is equipped with empty boil protection to prevent over-heating. When the tank is empty and at boiling mode, the empty boil protection will be switched on. However, a burnt mark may be resulted at the inner wall of the tank. Detachable lid : One can detach the lid by pressing down the mechanical lock at the hinge and at the same time pull out the lid at the range of 25° to 45°. Features : Auto keep warm Reboil Empty boil protection Detachable lid

25 -45

Published by Philips Domestic Appliances and Personal Care

Printed in Hong Kong

© Copyright

reserved

Subject to modification

4822 729 21999 12/98 Ver.1

SERVICE INFORMATION Inner tank : In case the inner tank is damaged, the appliance has to be replaced. Heater : When the appliance does not work, check the electrical circuit and the heater resistance. To measure the heater resistance : Disconnect all the wires to the heater terminals A, B and C. Use a ohm meter to measure the main heater terminal AB, the resistance should be 56 ohm ± 5%. Use a ohm meter to measure the keep wa r m h e a t e r t e r m i n a l AC, t h e resistance range should be at 529 ohm ± 5%. If the resistance of any of the heater exceeds the above resistance ranges, the appliance has to be replaced. Item 1 2 3 4 5 6 7 8 9 10 11 12 13
Terminal B

Description Lid Assembly Outlet pipe stand Glass pipe Pipe connector set Thermal fuse 109°C Thermal reed switch 80°C Auto thermostat 115/75°C Reboil thermostat 95/0°C Sensor holder set Thermostat 96/70°C Handle Tank Body Holder set Circuit board Socket set Base Rotating ring Base plate Cord set HK / Singapore Sealing set

Consist of

12NC 4822 442 01763 4822 256 10559 4822 530 10308

101,102,103,104

4822 528 11318 4822 252 11363

(TRS1) (T/S1) (T/S2) 105,106 (T/S3)

4822 282 10342 4822 282 10343 4822 282 13044 4822 256 10561 4822 282 10345 4822 498 10727 4822 441 12315

107,108,109,110,111

4822 410 12295 4822 214 13031

14
Terminal C

Terminal A

15 16 17 18 19 20

112,113

4822 265 11575 4822 464 10513 4822 532 13131 4822 442 00689 4822 321 11486

114, 115, 116

4822 532 13132

Note: Parts of number 100 onwards cannot be ordered separately.
Handle : To replace the handle (item 11), the inner tank has to be taken out. Put the handle in a horizontal position and pull at both sides.

T/S1 TRS 1

R KEEP WARM LAMP BOIL LAMP

INPUT

T/S2

T/S3

KEEP WARM HEATER

MAIN HEATER

R

EXPLODED VIEW

11

1

114

115 12 116 107 108 109 2 8 102 105 103 3 106 110 14 111 113 112 16 17

101

104 18 10 5

19 6

7