Text preview for : 06-NHM7-SERVSW.PDF part of Nokia NHM-7 Service Manual 5 File [part 1/3]



Back to : 6500_01_©_.zip | Home

3$06 7HFKQLFDO 'RFXPHQWDWLRQ 1+0 6HULHV 7UDQVFHLYHUV

6HUYLFH 6RIWZDUH ,QVWUXFWLRQV &RQFHSWV

,VVXH

1RNLD &RUSRUDWLRQ

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

[This page left intentionally blank]

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation Table of Contents

NHM-7 Service Software Instructions & Concepts

Page No Quick Guide for Phoenix Service SW Installation ........................................................ 4 Phoenix Installation Steps in Brief ..............................................................................4 Phoenix Service SW....................................................................................................... 5 Before Installation .......................................................................................................5 Startup ..........................................................................................................................6 Dongle Driver Installation and Version Check ...........................................................7 First Time Installation of Phoenix ...............................................................................8 Update Installation of Phoenix ..................................................................................11 How to Uninstall Phoenix ..........................................................................................12 Data Package for Phoenix (Product Specific).............................................................. 14 Before installation ......................................................................................................14 Installation of Phoenix Data Package (Product Specific) ..........................................15 How to Uninstall Data Package .................................................................................18 How to Manage Connections ....................................................................................... 19 Manual Settings....................................................................................................... 20 A) For FLS-4 POS Flash Device choose following connection settings ..............20 B) For FPS-8 Flash Prommer choose following connection settings: ..................20 How to Update Flash Support Files for FPS-8* and FLS-4* ...................................... 23 Before Installation .....................................................................................................23 Installing the Flash Support Files ..............................................................................23 How to Update The FPS-8* Flash Prommer SW ......................................................26 FPS-8 Activation and Deactivation.............................................................................. 28 Activation ..................................................................................................................28 Deactivation ...............................................................................................................28 JBV-1 Docking Station SW ......................................................................................... 29 Before Installation .....................................................................................................29 Installing SW Needed for the JBV-1 SW Update .....................................................30 Updating the JBV-1 Docking Station Software .........................................................34 Setup Instructions......................................................................................................... 36 Flash Concept ............................................................................................................36 Flash Concept - POS (Point of Sale) .........................................................................37 Parallel Flash concept ................................................................................................41

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

Quick Guide for Phoenix Service SW Installation

Phoenix Installation Steps in Brief
DCT-4 generation Test and Service Software is called "Phoenix" These are the basic steps to install the Phoenix
· · Install the Phoenix Service SW Install the Data Package for Phoenix (product specific data and flash update package) Manage connection settings (depends on the tools you are using) Update FPS-8 SW (if you use FPS-8) Activate FPS-8 Update JBV-1 Docking Station SW (only when needed)

· · · ·

The flash update files are delivered with then Phoenix Data Package so unless you want to use certain version of this package, separate installation package is not needed anymore. If you want to use it, it should be installed after connection management, before FPS-8 update. Please refer to Service Manual and Technical Bulletins for more information concerning phone model specific service tools and equipment setup.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Phoenix Service SW
Before Installation
· · Check that a Dongle is attached to the parallel port of your computer. Download the installation package (e.g. nhm7_npe4_npe9_03_55_000.exe) to your computer (e.g. C:\TEMP) Close all other programs Run the application file (e.g. nhm7_npe4_npe9_03_55_000.exe) and follow instructions on the screen Administrator rights may be required to be able to install Phoenix depending on the Operating System If dongle driver is installed or updated, you need to reboot your PC before the installation can continue. If uninstalling or rebooting is needed at any point, you will be prompted by the Install Shield program.

· ·

·

·

·

If at any point during installation you get this message, Dongle is not found and installation can´t continue. Possible reasons may be defective or too old PKD-1Dongle (five digit serial number Dongle when used with FPS-8 Prommer) or that the FLS-4 POS Flash Dongle is defective or power to it is not supplied by external charger. Check the COM /parallel ports used first! After correcting the problem Installation can be restarted.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

Startup
Run the nhm7_npe4_npe9_03_55_000.exe to start installation. When you choose "Next" the files needed for installation will be extracted. Please wait.

If the setup files are already extracted (left in the file system from previous installation) following dialog appears. Always click "Yes to All" to overwrite the existing setup files.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Dongle Driver Installation and Version Check
If there is no previously installed Dongle driver, installation will take place...

If the Dongle driver is installed and it is older than the latest supported version, the latest version will be installed when you choose "Yes". The latest version is always included in the latest Phoenix installation package.

PC needs to be rebooted before installation can continue. Click "Yes" to reboot the PC. Setup is restarted automatically after reboot.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

First Time Installation of Phoenix
After Dongle driver installation / update (if needed) installation continues from this step. Click "Next" in Welcome dialog to continue.

Choose the destination folder, it is recommended to use the default folder C:\ProgramFiles\Nokia\Phoenix. Choose "Next" to continue. You may choose another location by selecting "Browse" (not recommended)

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Setup copies the components.please wait. Progress of the setup is shown. Please wait...

If you need to reboot the PC, the Install Shield Wizard will tell you about it. Select "Yes..." to reboot the PC immediately and "No..." to reboot the PC manually. Note that Phoenix doesn't work, if components are not registered. Click "Finish" to continue.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

After the reboot components are registered and Phoenix is ready for use. If reboot is not needed components are registered after copying them.

If reboot of the computer is not needed, this view will be shown instead.

Click "Finish" to exit the setup. Phoenix is now ready for use. Now the installation of Phoenix Service SW is ready and it can be used after:
· · · Installing Phone model specific Phone Data Package for Phoenix Configuring the connections Updating the Flash Update Package files used with FPS-8* and FLS-4* tools

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Update Installation of Phoenix
If you already have the Phoenix Service SW installed on your computer, sooner or later there will be need to update it when new versions are released. Please note that very often the Phoenix Service SW and the Phone Specific Data Package for Phoenix come in pairs, meaning that certain version of Phoenix can only be used with certain version of Data Package. Always use the latest available versions of both. Instructions can be found in phone model specific Technical Bulletins. To update the Phoenix you need to take exactly the same steps as when installing it for the first time.
· · · · · · Download the installation package to your computer hard disk Close all other programs Run the application file (e.g. nhm7_npe4_npe9_03_55_000.exe) Dongle driver version will be checked and if need be, updated After reboot installation starts automatically Newer version of Phoenix will be installed

When you update the Phoenix from old to new version (e.g. update from 3.40 to 3.55), the update will take place automatically without uninstallation If you try update the Phoenix with the same version that you already have (e.g. 3.55 to 3.55) you are asked if you want to uninstall the version of Phoenix you have on your PC. Answer "OK" to uninstall Phoenix, "Cancel" if you don't want to uninstall.

If you try to install an older version (e.g. downgrade from 3.55 to 3.40) installation will be interrupted. Always follow the instructions on the screen.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

How to Uninstall Phoenix
Uninstallation can be done manually from Windows Control Panel - Add / Remove Programs. Choose "Phoenix NHM-7 / NPE-4 / NPE-9 Release" click "Add/Remove". Choose "OK" to uninstall

Progress of the uninstallation is shown.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

You may have to reboot the PC after uninstallation.

If restarting is not needed, the following dialog will appear:

Note! If you have different product packages installed, components are uninstalled only if they are not included in other product packages.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

Data Package for Phoenix (Product Specific)
Before installation
Product Data Package contains all product specific data to make the Phoenix Service Software and tools usable with a certain phone model. It also includes the latest version of flash update package for FLS-4* and FPS8*
· · · Check that the Dongle is attached to the parallel port of your computer. Install Phoenix Service SW Download the installation package (e.g. nhm-7_dp_v_6.00.exe) to your computer (e.g. C:\TEMP) Close all other programs Run the application file (e.g. nhm-7_dp_v_6.00.exe) and follow instructions on the screen

· ·

If you already have the Phoenix Service SW installed on your computer, sooner or later there will be need to update it when new versions are released. Please note that very often the Phoenix Service SW and the Phone Specific Data Package for Phoenix come in pairs, meaning that certain version of Phoenix can only be used with certain version of Data Package. Always use the latest available versions of both. Instructions can be found in phone model specific Technical Bulletins.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Installation of Phoenix Data Package (Product Specific)
Run the nhm-7_dp_v_6.00.exe to start installation. When you choose "Next" the files needed for installation will be extracted. Please wait...

Choose "Next" to continue.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

From this view you can see the contents of the Data Package. Read the text carefully. There should be information about the Phoenix version needed with this data package. Choose "Next".

Confirm location and choose "Next" to continue. Install shield checks where the Phoenix application is installed and the directory is shown. Choose "Next" to continue.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Phone model specific files will be installed... please wait.

Choose "Finish" to complete installation.

You now have all phone model specific files installed in your Phoenix Service SW.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

How to Uninstall Data Package
Uninstallation can also be done manually from Windows Control Panel / Add / Remove Programs/ "NHM-7 Phone Data Package". If you try to install the same version of Phoenix Data Package that you already have, you are asked if you want to uninstall the version you have on your PC. Answer "OK" to uninstall, "Cancel" if you don't want to uninstall. Older versions of data packages do not need to be uninstalled.

Once the previously installed Data package is uninstalled, choose "Finish".

Run the nhm-7_dp_v_6.00.exe again to continue installation from the beginning.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

How to Manage Connections
Start Phoenix Service SW and Login.

Choose "Manage Connections" From "File" ­ Menu

Existing connections can be selected, edited, deleted and new ones created by using this dialog. A connection can be created either manually or by using a Connection Wizard. To add new connection, choose "Add" and select if you want to create it manually or by using the Wizard.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts Choose "Next" to continue.

PAMS Technical Documentation

In the next dialogs you will be asked to select some settings for the connection

Manual Settings A) For FLS-4 POS Flash Device choose following connection settings Media: FBUS COM Port: Virtual COM Port used by FLS-4 Please check this always! (To check please go to Windows / Control Panel / FLS Virtual Port / Configuration) B) For FPS-8 Flash Prommer choose following connection settings: Media: FPS-8 Port Num: COM Port where FPS-8 is connected COMBOX_DEF_MEDIA: FBUS Choose "Finish" to complete.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

If you use the Wizard, connect the tools and a phone to your PC and the wizard will automatically try to configure the correct connection. Activate the connection you want to use by clicking it and use up/down arrows to move it on top of the list. Choose "Apply". The connection is now selected and can be used after closing the "Manage Connections" window.

Selected connection will be shown on the right hand bottom corner of the screen.

To use the selected connection, connect the phone to Phoenix with correct service tools, make sure that it is switched on and select "Scan Product".

When the Product is found, Phoenix will load product support and when everything is ready, name of the loaded product support module and its version will

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts be shown on the bottom of the screen.

PAMS Technical Documentation

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

How to Update Flash Support Files for FPS-8* and FLS-4*
Before Installation
Install Phoenix Service SW and Phoenix data package. Download the installation package (e.g. flash_update_02_03_000.exe) to your computer (e.g. C:\TEMP). Close all other programs. Run the application file (e.g. flash_update_02_03_000.exe) and follow instructions on the screen.
Note: · The flash support files are delivered in the same installation package with Phoenix data package. Normally it is enough to install the data package only before updating the FPS8. Separate installation package is for flash support files is available, and the files can be updated according to this instruction.

·

·

Installing the Flash Support Files
Start by double clicking flash_update_02_03_000.exe. Installation begins.

If you already have the same Flash Update package files installed, you need to confirm if you want them to be reinstalled.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts Choose "Next" to continue installation

PAMS Technical Documentation

It is highly recommended to install the files to the default destination folder C:\Program Files\Nokia\Phoenix. Choose "Next" to continue. You may choose another location by selecting "Browse" (not recommended).

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation Installation continues...

NHM-7 Service Software Instructions & Concepts

Choose "Finish" to complete procedure.
· · FLS-4 can be used right after Flash Update Package is installed. FPS-8* must be updated by using Phoenix!

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

How to Update The FPS-8* Flash Prommer SW
Start Phoenix Service Software .

Select"FPS-8 / FPS-8C maintenance" from"Flashing" menu.

When new FPS-8 flash update package is installed to computer you will be asked to update the files to your FPS-8 Prommer. Select"Yes" to update files.

Update procedure takes a couple of minutes.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

FPS-8 sw can also be updated by pressing"Update" button and selecting appropriate fps8upd.ini file under C:\Program Files\Nokia\Phoenix\Flash directory

All files can be loaded separately to FPS-8. To do this, just press right mouse button in Flash box files" window and select file type to be loaded. More information and help can be found from "Help" dialog.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

FPS-8 Activation and Deactivation
· Before the FPS-8 can be successfully used for phone programming, it must be first activated. If there is a need to send FPS-8 box to somewhere e.g. for repair, box must be first deactivated. Note: Phoenix should be closed before running BoxActivation.exe.

·

·

Activation
Before FPS-8 can be successfully used for phone programming, it must be first activated. Fill in first "FPS-8 activation request" sheet, in the FPS-8 sales package and follow the instructions in the sheet. When activation file is received (e.g. 00000.in), copy it to C:\ProgramFiles\Nokia\Phoenix\BoxActivation - Directory on your computer (This directory is created when Phoenix is installed). Start BoxActivation.exe from C:\ProgramFiles\Nokia\Phoenix\BoxActivation ­ directory. Follow the instructions in the screen.
&KRRVH FRUUHFW &20 3RUW ZKHUH \RXU )36 LV FRQQHFWHG ,QIRUPDWLRQ DERXW WKH )36 LV VKRZQ &KRRVH ¦$FWLYDWH WKH %R[§ $FWLYDWLRQ ILOH ZLOO EH VKRZQ FKHFN WKDW LW LV FRUUHFW %R[ ZLOO EH DFWLYDWHG DQG XSGDWHG LQIRUPDWLRQ LV VKRZQ 7XUQ )36 SRZHU RII DQG RQ WR FRPSOHWH DFWLYDWLRQ

Deactivation
Start BoxActivation.exe from C:\ProgramFiles\Nokia\Phoenix\BoxActivation directory and follow the instructions in the screen.
1. Choose correct COM Port where your FPS-8 is connected 2. Information about the FPS-8 is shown 3. Choose "Deactivate the Box" 4. Confirm Deactivation. 5. Box will be deactivated, please exit BoxActivation 6. Turn FPS-8 power off and on to complete deactivation

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

JBV-1 Docking Station SW
The JBV-1 Docking Station is a common tool for all DCT-4 generation products. In order to make the JBV-1 usable with different phone models, a phone specific Docking Station Adapter is used for different service functions. The JBV-1 Docking Station contains Software (Firmware) which can be updated. You need the following equipment to be able to update JBV-1 software: · · · PC with USB connection Operating System supporting USB (Not Win 95 or NT) USB Cable (Can be purchased from shops or suppliers providing PC hardware and accessories) JBV-1 Docking Station External Power Supply 11-16V

· ·

Before Installation
· Download Jbv1_update.zip ­ file to your computer (e.g. C:\TEMP) from your download web site. Close all other programs Follow instructions on the screen

· ·

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

Installing SW Needed for the JBV-1 SW Update
Note: DO NOT CONNECT THE USB CABLE / JBV-1 TO YOUR COMPUTER YET!

Run Jbv1_update.zip file and start SW Installation by double clicking Setup.exe. Files needed for JBV-1 Package setup Program will be extracted.

Installation begins, please read the information shown and Choose "Next" to continue. .

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Use suggested destination folder where JBV-1 SW Package will be installed and choose "Next" to continue.

Select "Full" Installation and choose "Next" to continue

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

Program Folder will be created. Choose "Next" to continue, Software files will be installed.

After successful installation, choose "Finish" to complete.

NOW YOU CAN CONNECT THE USB CABLE / JBV-1 TO YOUR COMPUTER! 1RNLD &RUSRUDWLRQ

3DJH

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Connect power to JBV-1 (11-16V DC) from external power supply, then connect USB Cable between JBV-1 USB connector and PC. Windows will detect connected USB cable and detect drivers for new HW. Please follow the instructions and allow Windows to search and install the best drivers available. After this procedure the actual JBV-1 SW update can begin.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

Updating the JBV-1 Docking Station Software
Go to folder C:\Program Files\Nokia\ JBV-1 SW Package\ FIRMWARE UPDATE and start JBV-1 Update SW by double clicking fwup.exe. JBV-1 Firmware update starts and shows current status of the JBV-1 connected. If firmware version read from your JBV-1 is not the latest one available, it needs to be updated by choosing "Update Firmware".

Choose file JBV1v11.CDE (example used here is for v 11) and "Open" to update your JBV-1.

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

After Successful update, current JBV-1 status will be shown. You have now updated the software of your JBV-1 docking station and it is ready for use.

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

Setup Instructions
Flash Concept
7

9 8 6 5

4

3 2

1

Figure 1: Flash concept

,WHP

6HUYLFH DFFHVVRU\ 3RLQW 2I 6DOHV IODVK ORDGLQJ DGDSWHU 3RZHU FDEOH 0RGXODU FDEOH )ODVK SURPPHU ER[ 3ULQWHU FDEOH ' ' FDEOH 6RIWZDUH SURWHFWLRQ NH\ 3KRHQL[ 6HUYLFH 6: 3KRHQL[ 6HUYLFH 6: 1+0 )ODVK 6: GDWD 1+0 )ODVK 6: GDWD &'520 &'520 )/$ )/& ;&6 )36 LQFO LQ )36 VDOHV SDFN $;6 LQFO LQ )36 VDOHV SDFN 3.'

3URGXFW FRGH



$& &KDUJHU LQFO LQ )36 VDOHV SDFN

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Flash Concept - POS (Point of Sale)

4

5 2 3

1

Figure 2: POS flash

,WHP

6HUYLFH DFFHVVRU\ 3RLQW 2I 6DOHV IODVK ORDGLQJ DGDSWHU 6HUYLFH FDEOH $& &KDUJHU 326 IODVK GRQJOH IRU ($ DUHD 326 IODVK GRQJOH IRU $3$& DUHD

7\SH )/$ ;&6 $&3 VHH FKDSWHU *HQHUDO ,QIRU PDWLRQ'HVNWRS )/6 )/6 : &'520 1+0 )ODVK 6: GDWD &'520

3URGXFW FRGH





3KRHQL[ 6HUYLFH 6: 3KRHQL[ 6HUYLFH 6: 1+0 )ODVK 6: GDWD 1+0 )ODVK 6: GDWD

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

JBV-1 Flash Concept

Figure 3: JBV-1 Jig concept

,WHP

6HUYLFH DFFHVVRU\ 'RFNLQJ VWDWLRQ 'RFNLQJ VWDWLRQ DGDSWHU

7\SH -%9 0-) 3&6 ;&6 )36 ,QFO LQ )36 VDOHV SDFN $;6 LQFO LQ )36 VDOHV SDFN 3.' 3KRHQL[ 6HUYLFH 6: 3KRHQL[ 6HUYLFH 6: LQ &'520 1+0 )ODVK 6: GDWD 1+0 )ODVK 6: GDWD LQ &'520 ,QFO LQ )36 VDOHV SDFN

3URGXFW FRGH



'& SRZHU FDEOH 0RGXODU FDEOH )ODVK SURPPHU ER[ 3ULQWHU FDEOH ' ' FDEOH 6RIWZDUH SURWHFWLRQ NH\ 3KRHQL[ 6HUYLFH 6: 3KRHQL[ 6HUYLFH 6: LQ &'520 1+0 )ODVK 6: GDWD 1+0 )ODVK 6: GDWD LQ &'520



$& &KDUJHU

3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Jig Concept
5

6 4 2 1

3

Figure 4: Module jig concept

,WHP

6HUYLFH DFFHVVRU\ 0RGXOH MLJ '& SRZHU FDEOH 5) DQWHQQD FDEOH 6HUYLFH 0%86 FDEOH 6RIWZDUH SURWHFWLRQ NH\ 3KRHQL[ 6HUYLFH 6: 3KRHQL[ 6HUYLFH 6: 1+0 )ODVK 6: GDWD 1+0 )ODVK 6: GDWD

7\SH 0-6 3&6 ;5) '$86 3.' : &'520

3URGXFW FRGH

&'520



,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

CPL-4 Service Concept

8

9 7

5 4

6 3 2 1
Figure 5: CPL-4 concept

,WHP

6HUYLFH DFFHVVRU\ -%9 'RFNLQJ VWDWLRQ 0-) 'RFNLQJ VWDWLRQ DGDSWHU &3/ &RXSOHU 6&% '&'& FDEOH ;5) 5) DQWHQQD FDEOH 3&6 '& SRZHU FDEOH '$86 6HUYLFH 0%86 FDEOH 3.' 6RIWZDUH SURWHFWLRQ NH\ 3KRHQL[ 6HUYLFH 6: 3KRHQL[ 6HUYLFH 6: 1+0 )ODVK 6: GDWD 1+0 )ODVK 6: GDWD

7\SH -%9 'RFNLQJ VWDWLRQ 0-) 'RFNLQJ VWDWLRQ DGDSWHU &3/ &RXSOHU 6&% '&'& FDEOH ;5) 5) DQWHQQD FDEOH 3&6 '& SRZHU FDEOH '$86 6HUYLFH 0%86 FDEOH 3.' 6RIWZDUH SURWHFWLRQ NH\ : &'520

3URGXFW FRGH

&'520



3DJH

1RNLD &RUSRUDWLRQ

,VVXH

PAMS Technical Documentation

NHM-7 Service Software Instructions & Concepts

Parallel Flash concept

Figure 6: Parallel flash concept

,WHP

6HUYLFH DFFHVVRU\ 0-) 'RFNLQJ VWDWLRQ DGDSWHU -%9 'RFNLQJ VWDWLRQ ;&6 0RGXODU FDEOH 3&6 '& SRZHU FDEOH ' ' FDEOH 3ULQWHU FDEOH 6RIWZDUH SURWHFWLRQ NH\ 3KRHQL[ 6HUYLFH 6: 3KRHQL[ 6HUYLFH 6: 1+0 )ODVK 6: GDWD 1+0 )ODVK 6: GDWD

7\SH 0-)U -%9 ;&6 3&6 $;6 LQFO LQ )36& VDOHV SDFN ,QFO LQ )36& VDOHV SDFN 3.'

3URGXFW FRGH

&'520



&'520 )36&





3DUDOOHO IODVK SURPPHU

,VVXH

1RNLD &RUSRUDWLRQ

3DJH

NHM-7 Service Software Instructions & Concepts

PAMS Technical Documentation

>7KLV SDJH OHIW LQWHQWLRQDOO\ EODQN@

3DJH

1RNLD &RUSRUDWLRQ

,VVXH