Text preview for : CROWN DC300A.pdf part of Crown DC300 power amplifier
Back to : CROWN DC300A.pdf | Home
w
crolun
DC-300A IM-9
S3P2-15-6
INSTRUCTION MANUAL
SERIAL NO ISSUED
DUAL CHANNEL LABORATORY AMPLIFIER
DC-300A
CROWN INTERNATIONAL, INC., BOX 1000, ELKHART, INDIANA 46514
0
Serial Number
1. Quies. offset of less than 1OmV 2. 1 KHz 180 watts RMS minimum into 8 ohms, per channel, both channels operating, 0.1% total harmonic distortion 4 ohm test
w
crown
In-runaTlonac
BATCH I D
SERIAL NO 020163
Proof of Performance Report
DC-300A laboratory power amplifier
Amcron Label
DCA-11
Line Voltage Requirement\ao,VAC
CH.l J
CH.2 J
3.
,/
4. Protection tests 5. Reliability test
\
6. 20KHz 1 5 5 w a t t s p e r c h a n n e l minimum RMS (both channels operating) into 8 ohm. 0.05% total harmonic distortion 7. 10 KHz. sq. wave
8. Mono operation 9. IM Dist. into 8 ohms (%) (60-7KHz 4:1) S.M.P.T.E. 155W 49.0W 15.5w 4.9w 1.55w 490mW 155mW .. 4 9 m W c ci/ Y' 15.5mW `2 1 db la/db z -002 -002 * c?oJ. _ cl03 _ @O'j .00cc
10.
Hum and noise-db below 155W into 8 ohm (20Hz - 20KHz)
11.
Quies. AC power input at 120 VAC is a W
see reverse side for explanation of tests performed
`TOTAL
PERFORM A N CE
IS WHAT COUNTS"
4. Protection Test - This is a test with a 2 ohm load which determines the threshold at which the protection circuitry will be activated. Sharp clipping should occur with no evidence of instability. The positive and negative limiters operated independently and therefore may not be activated simultaneously. Reliability Test - This test puts the output stages through an extremely vigorous thermal cycling. The test is a very low frequency input signal driving the output to full power across a short circuit for a predetermined period of time. 20KHz
CROWN test and check-out procedures reflect our basic design philosophy; we believe that reliability can be engineered into a product. As such, our check-out is designed to expose and correct a problem, before it happens. This testing begins when the unit is still a pile of parts; grading and selection of components is standard. The final test-inspection is the culmination of this vigorous program, but our concern doesn't stop here. Our products are backed by an extensive field service program, and protected by a comprehensive warranty. A word about our testing procedure is in order. All our specifications are referenced to an AC input of 120 VAC. The high current demand with high power tends to cause the line voltage to sag, or the sinusoidal waveform to distort. With a distorted waveform (or lower line voltage) the peak voltage is lowered. Since it is the peaks that charge the filter capacitors in the amplifier power supply, and thus determine the maximum power output, a line voltage problem reduces the maximum power output. CROWN uses a peak equivalent AC voltmeter which measures the peaks of any waveform and converts this to an equivalent rms reading for a sinusoidal waveform. This way we can vary or regulate the line voltage, no matter how distorted the waveform, to an equivalent of a 120 VAC sinewave. We are then measuring a true maximum output power. With regard to the precision load which we use for our testing, we realize that a resistive load is quite different than a reactive speaker. However, using readily available parts, a precision resistive load is the easiest to duplicate, with respect to obtaining consistent results. We specify that the load must be resistive, having less than 10% reactive component at any frequency up to five times the highest test frequency. The resistance value should be maintained within 1%, at all power levels.
5.
6.
-
This tests the amplifier at its rated power level.
We specify that at any frequency between 1Hz and 2OKHz the DC-300A will produce 155 watts minimum rms (both channels operating) into an 8 ohm load, at a sum total harmonic distortion of .05% or less. We choose 20KHz as the test frequency because high frequencies produce more heat than lower frequencies. Thus, if the amplifier can safely pass the 20KHz test, it will operate safely at lower frequencies. 7. 10 KHz Square Wave - This test critically examines the amplifier's frequency response and rise time. (How fast the amplifier can follow rapid signal changes.) The output square wave (with an 8 ohm load) should be clean and sharp, with no ringing or overshoot. Mono Operation - This is a check for proper operation of the stereo mono switch. A signal is applied to channel 1 input only and the mono output is observed between the two red output terminals of the amplifier. IM D i s t o r t i o n T e s t - A t C R O W N w e f e e l t h a t I M distortion testing yields a truer picture of amplifier performance than harmonic distortion testing. While a large amount of documentation supports this opinion, some of the reasons are apparent, even in layman's terms. For example, a sinusoidal waveform (used in HD testing) bears little resemblance to the complex waveforms
8.
9.
The following discussion examines each of the test procedures listed on the facing page. This is an attempt to help you understand, in layman's terms, what the tests mean.
associated with actual program materials. IMD testing uses such a complex waveform. Also, harmonic distortion is not always aurally offensive. The human ear may interpret such distortion as pleasing, but usually finds IM distortion rather obnoxious. In order to support this design philosophy, we designed and built our own IM analyzer with residual noise and distortion low enough to test our amplifiers. 10. Hum and Noise
Quiescent Offset
-
This simply
assures
that
your
amplifier's output is balanced with reference to its input. Thus the amplifier will not "bias" the program with a dc component. To meet specifications, offset must be less than 10 mv. 1KHz - This test measures the power across an 8 ohm load at a frequency of 1 KHz with both channels operating. This is a determination of how much power an amplifier can produce before a specified total harmonic distortion is reached. For the DC-300A, the power is 180 watts a t l e s s t h a n .1% T H D . 4 Ohm Test
-
This test, in plain English, tells you how
small a signal can be amplified without it becoming "lost in the mud". The test is limited to the audio band width of 20Hz-20KHz, with a bandpass filter. Our specification for the DC-300A is: hum and noise from 20Hz - 20KHz will be at least 110db below the full power output of 155 watts. This means that with a 155 watt output the noise will be only .00155 micro watts. (That's 1.55 billionths of a watt 11.
) This test
-
This is a critical examination of the DC-300's
Quiescent AC power Input at 120 VAC
performance at impedances below that for which it is rated. We check the wave form for level (it must reach a specified voltage before clipping) purity, and stability.
confirms that your amplifier is not drawing excessive power while "idling". If an amplifier exhibits a tendency toward instability, or oscillation, it may draw power with no signal input. The DC-300A will draw 40 watts or less at idle.
TABLE OF CONTENTS
Section 1 1 .1 1.2 1 .3 PAGE DESCRIPTION General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2, 3, 4, 5 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ... 12
Section 2 INSTALLATION . 2.1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 13 2.2 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . 13 2.3 Normal Hi-Fi Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.4 Connecting Output Lines ................................................................................................, 14 2.4.1 Mono Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 2.5 Connecting Input Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 2.6 Connecting Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Section 3 3.1 3.2 3.3 3.4 3.5 Section 4 4.1 4.2 4.3 OPERATING INSTRUCTIONS Controls and Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 The Protection Mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Operating Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Load Protection Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 CIRCUITRY Principles of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 24 Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ......
Section 5 APPLICATION NOTES Application Note No. 1 - V-l Limits of a Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Application Note No. 2 - VFX-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 29 Application Note No. 3 - Speaker Protection . . . . . . . . .......................................................
LIST OF ILLUSTRATIONS
TITLE PAGE l - l DC-300A Pictorial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 l-2 DC-300A Performance Graphs I.M. Distortion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Harmonic Distortion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Frequency Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Power Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Phase Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Noise Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 8 Crossta Ik . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .._.............. Nominal Limits of V-l Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Damping Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Power Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Input Impedance vs. Gain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2-l 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 2-10 3-l 3-2 3-3 3-4 3-5
Maximum Output vs. Load Impedance ............................................................................ output (Z) ............................................................................................................................ output IL I.. ........... . .............................................................................................................. Mounting Dimensions ....................................................................................................... Normal Hi-Fi Hook-up ........... ............................................................................................. Rear View of Chassis ...... .................................................................................................. Source Resistance and Damping Factor vs. Length and Size of Output Leads ............ Schematic For Full Range Electrostatic Speaker Connections ...................................... Schematic of Earphone Pad .............................................................................................. DC-3ODA Mono Hook-up ................................................................................................... Table For Selection of Input DC Blocking Capacitor ....................................................... Low-Pass Filter For Severe RF At Inputs ......................................................................... Table of Line Voltage Connections ................................................................................... Operating Controls ........ ..................................................................................................... Graph of VI Operating Range of DC-300A Output ......................................................... Fuse Selector Nomograph For Loudspeaker Protection .................................................. Relay Controlled Protector with Overload Indicator ........................................................ Turn-On-Transient Muter For Load Protection ................................................................
11 12 12 13 14 14 15 15 16 16 17 17 18 19 20 22 22 22
Section 1
DESCRIPTION
1 .1 GENERAL
DC-300A PICTORIAL The DC-300A is a dual-channel high-power amplifier for precision amplification of frequencies from DC to 20KHz. The unit features extremely low harmonic and intermodulation distortion, very low noise, highest "damping factor," and quality parts and workmanship. Because of the large output power, It is possible to obtain a monaural 70-volt balanced line without using an output transformer. The DC-300A contains a new CROWN developed Signal Programmed Automatic Current Executor (SPACE control) electronic amplifier protection circuit which manifests no flyback pulses, thumps, or shut-down. At audio frequencies any impedance load including totally reactive loads may be driven with no adverse effects. Only maximum output power will be affected by variations in load impedance. At sub-sonic to DC frequencies the limiter acts as a VI limiter to provide optimum protection for the extremely rugged silicon hometaxial output devices (total of 16 for a total of 2400W dissipation). A pair of thermal switches remove power from the unit if overheating occurs due to insufficient ventilation, The AC line is fused to protect the power supply. See Section 3.2 for a description of the protective systems. The power supply features a 1 KW transformer and large computer-grade filter capacitors giving over 48 joules of energy storage. A total of 44 discrete transistors, 1 linear IC (dual op amp), Front-panel controls include two independent heavy-duty level controls and a power switch with an associated pilot light. DC balance controls, which never need adjustment in normal operation, are located behind the front-panel. 26 diodes, 1 bridge rectifier, and 3 zener diodes are used in the DC-3OOA circuitry. With the integrated circuit, the effective number of semiconductors is 60 transistors, 30 diodes, and 3 zener diodes.
The output devices, 8/channel, are conservatively employed, having a total peak current rating/channel of 120 amps in a circuit that is limited to a maximum of 28 amps. Among its unique features, the circuitry includes the CROWN-pioneered and patented AB+B output configuration. The input operational amplifiers are powered by two voltage-regulated supplies. This results in complete channel-to-channel isolation and independence from line voltage variations. Total direct coupling results in perfect, instantaneous, thump-free overload recovery even on non-symmetrical waveforms. This cannot be said for any AC-coupled amplifier presently in existence. Turn-on is instantaneous with no program delays.
1.2 SPECIFICATIONS 1.2.1 STEREO SPECIFICATIONS
Output Power
155 watts per channel minimum RMS (both channels operating) into an 8 ohm load over a bandwidth of 1 Hz-20KHz at a rated RMS sum total harmonic distortion of 0.05% of the fundamental output voltage.
±0.1dB DC-20KHz at 1 watt into 8 ohms; ±ldB DC-100KHz. 180 watts RMS into 8 ohms, per channel, both channels operating, 0.1% total harmonic distortion. Less than 0.001% from 20Hz-400Hz. and increasing linearly to 0.05% at 20KHzat 155watts RMS per channel into 8 ohms. Less than 0.05% from 0.01 watts to 0.25 watts and less than 0.01% from 0.25 watts to into 8 ohms, per channel. 155watts
Frequency Response 1 KHz Power Harmonic Distortion
I.M. Distortion (60Hz-7KHz 4:1) Slewing Rate
8 volts per microsecond (slewing rate is the maximum value of the first derivative of the output signal, or the maximum slope of the output signal).
Damping Factor Output Impedance Load Impedance Voltage Gain Input Sensitivity Output Signal
Greater than 750, DC-400Hz into 8 ohms. Less than 7 milliohms in series with less than 3 microhenries. Rated for 8 ohm usage; safely drives any load Including completely reactive loads. 20.6±2% or 26.3±0.2dB at maximum gain. 1.75 volts±2% for 155 watts into 8 ohms. Unbalanced, dual channel.
1 . 2 . 2 MONAURAL SPECIFICATIONS
Output Power
310 watts minimum RMS into a 16 ohm load over a bandwidth of 1 Hz-20KHz at a rated RMS sum total harmonic distortion of 0.05% of the fundamental output voltage.
±0.15dB, DC-20KHz at 1 watt into 16 ohms; ±1 dB, DC-6OKHz at 1 watt into 16 ohms. 360 watts RMS into 16 ohms. Less than 0.001% from 20Hz-400Hz and increasing linearly to 0.05% at 20KHz at 310 watts into 16 ohms. Less than 0.05% from 0.01 watts to 0.25 watts and less than 0.01% from 0.25 watts to 310 watts into 16 ohms. 16 volts per microsecond. Greater than 700, DC-400Hz into 16 ohms. Less than 15 milliohms in series with less than 6 microhenries. Rated for 16 ohm usage; safely, drives any load including completely reactive loads. 41.2±2% or 32.3±0.2dB at maximum gain. 1.75 volts for 310 watts into 16 ohms. Balanced, single channel.
Frequency Response 1 KHz Power Harmonic Distortion
I.M. Distortion Slewing Rate
Damping Factor Output impedance Load Impedance Voltage Gain Input Sensitivity Output Signal
4
1.2.3 GENERAL SPECIFICATIONS
Hum and Noise (20Hz-20KHz) Phase Response Input Impedance Amplifier Output Protection Overall Protection 110dB below rated output
+0, - 1 5 ° Zero to 20KHz at 1 watt 100K ohms at minimum gain, 10K ohms at maximum gain. Short, mismatch, and open circuit proof. Limiting is instantaneouswith noflyback pulses, thumps, cutout, etc. No premature limiting on transients. AC line fused. Thermal switch in AC line protects against overheating caused by insufficient ventilation. Controlled slewing rate voltage amplifiers protect overall amplifier against RF burnouts. Input overload protection is furnished by internal resistance at inputs of amp. instantaneous, with minimum thumps and no program delay. Wideband multiple feedback loop design utilizing one linear IC (dual op-amp). Total equivalent of 60 transistors, 30 signal diodes, 3 zeners and 6 rectifier diodes. 1 kilowatt transformer with massive computer-grade filter capacitors storing over 48 joules of energy. Two regulated supplies for complete isolation and stability. Requires 50-4OOHz AC with selectable taps for 100, 120, 200, 220 and 240V ±10% operation. Draws 40 watts or less on idle, 500 watts at 300 watts total output. Massive black-anodized heat sinks are thermally joined with the chassis, thereby utilizing the entire amplifier as a heat sink. All aluminum construction for maximum heat conduction and minimum weight. Heavy aluminum front panel is a single extrusion. Independent input level controls are on front panel. Power switch, with integral pilot light is on front panel. Non-interacting DC balance controls are mounted behind front panel. A mono-stereo switch is located above the input jacks on the rear panel. Input - ¼ inch phone jack Output - Color coded binding posts AC Line - Three-wire (grounded) male connector on 5 ft. min. cable 19 inch standard rack mount (W.E. hole spacing), 7 inches high, 9 ¾ inches deep (from mounting surface). 45 pounds Satinized aluminum front panel, with gray suede Lexan insert.
Turn-on Circuit
Power Supply
Power Requirements
Heat Sinking
Chassis
Controls
Connectors
Dimensions
Weight Finish
10
TO DC
10
100
FREQUENCY (Hz)
1K
10K
1OOK
60
10
100
1KHz
FREQUENCY (Hz)
1OKHz
1OOKHz
Section 2
INSTALLATION
2.1 UNPACKING
As soon as the amplifier shipment is received, please inspect for any damage incurred in transit. Since the unit was carefully inspected and tested at the factory, it left the factory unmarred. If damage is found, notify the transportation company immediately. Only the consignee may institute a claim with the carrier for damage during shipment. However, CROWN will cooperate fully in such an event. Se sure to save the carton as evidence of damage for the shipper's inspection. Even if the unit arrived in perfect condition -as most do it is advantageous to save the packing materials. They will prove valuable in preventing damage should there ever be occasion to transport or ship the unit. Note the carton and internal pack - each is designed for protection during transit, particularly of the power transformer weighing over 25 Ibs. Do nof ship the unit without this factory pack! an air space should be allowed above and below the unit. If sufficient ventilation is not provided, the unit will intermittently turn off due to the built-in thermal protection. Such a condition (if observed) will also be accompanied by a warm front-panel due to the integral heat-sinking employed in the amplifier. Applications requiring long sustained signals at high power levels may require the use of a cooling fan.
2.3 NORMAL HI-FI INSTALLATION
1. Remove output covers, exposing dual binding-posts. Two-conductor speaker cables must connect to the OUTPUTS using terminal lugs, tinned ends, or the special "banana" plugs supplied with the DC-300A. Connect the in-line fuses as recommended in the Accessory Bag and Fig. 2-2. (Not needed with CROWN speakers.) 2. Since the DC-300A is a "basic amplifier," the main outputs of the control-center or "preamplifier" must be connected via shielded audio-cables to the two jacks marked INPUT. Use RCA-pin at preamp and standard ¼ inch phone-plug at the DC-300A. The two cables should be tied parallel along their entire length, using the accessory cable ties. 3. U/L requirements specify a 3-wire AC power connector; however, proper connections to a switched outlet on the control center require the use of a 3-to-2 wire adapter. NOW, plug the AC into a switched outlet on the control center. 4, Your Control Center may now be turned on. Then advance the DC-300A Input-Gain Controls about %-open (1 50° clockwise). When using the CROWN IC-150A Control-Center, the VOLUME should attain almost full rotation (2 to 4 o'clock) for loudest "concert-hall"volume. If at 3 o'clockthevolume is low, increase the DC-300A input gain controls; if too high, decrease the DC-300A gains.
2.2 MOUNTING
The DC-3DDA is designed on a standard 19 inch rack mounting format. However, it may be custom mounted if sufficient support is provided. For dimensions see Fig. 2-1. In any circumstance, sufficient ventilation must be provided for the unit. Good ventilation practice allows air to flow completely under, around, and through the amplifier. If the unit is placed above a horizontal surface,
-I-
r
7
FIG. 2 - 1 MOUNTING DIMENSIONS
To assure maximum enjoyment and full speaker protection, read the following detailed sections on OUTPUTS, INPUTS and Chapter 3-OPERATION.
13
CONTROL CENTER
3 to 2 WIRE ADAPTER / RIGHT SPEAKER SWITCHED OUTLET /
POWER CABLE _
JJ
lb---
CABLE TIE(S) SHIELDED AUDIO CABLES Or A o'hl TO ¼ " PHONE 7 ) MONO-STEREO SWITCH LEFT SPEAKER
MDP PLUGS DUAL BANANA NOTE! / IN-LINE FUSES
FIG. 2-2 NORMAL HI-N HOOK-UP
2.4 CONNECTING OUTPUT LINES
Input and output connectors are located on the back of the chassis as shown in Fig. 2-3. It is always wise to remove power from the unit and turn the input level controls off while making connections,
especially eliminate liable for its being
if the load is a loudspeaker system. This will any chance of loud blasts. CROWN is not damage incurred to any transducer due to overpowered! (CROWN speakers excepted.)
Before making connections, it is recommended that the operator familiarize himself with the amplifier's protective system. See Section 3.2. Section 3.3 entitled "Operating Precautions" should also be read. Because of the location of the output connectors (colorcoded binding posts), it will be easiest to make these connections first. High-quality, dual "banana" plugs are the preferred connections for permanent installations, critical applications, and when testing the amplifier. Because the output wire gauge and length raises the resultant source impedance or lowers the Damping Factor by adding its series resistance, the nomograph (Fig. 2-4)
REAR OF CHASSIS WITH OUTPUT COVERS REMOVED
15
40
7. .04 Rl s-.06 R,
8000 5000
RL
LOAD 30
RESISTANCE
(ohms)
R,
SOURCE RESISTANCE
~MOOO ft.1 -- ANNEALED
1000 T 2-COND. 500.-
- - .l DAMPING
COPPER WIRE
IAWGI
CABLE
20
--
50.---t24 15
10 9 8 7
6
5
4
FIG. 2-4 SOURCE RESISTANCE AND DAMPING FACTOR VS. LENGTH AND SIZE OF OUTPUT LEADS
is provided for wire selection. For dynamic moving-coil loudspeakers the value of RL should preferably be that measured by an ohmmeter across the voice coil, rather than the manufacturer's rating. For electrostatic speakers and such, the manufacturer's rated impedance should be used for R. If the load (matching transformer, inductance, or fullrange electrostatic speaker system) appears as a shortcircuit at low frequencies, a large non-polarized capacitor (paralleled with a resistor) should be placed in series with the load. For electrostatic speakers (if the manufacturer has not provided a capacitor) an external non-polar capacitor of 590-708 mfd and 4 ohm power resistor should be placed in series with the plus (+) speaker lead. This will prevent large low-frequency currents from damaging the electrostatic transformer or from unnecessarily activating the DC-3OOA's protective systems. An effective test to determine if such parts are needed is to F/G. 2-5 SCHEMA TIC FOR FULL RANGE ELECTROSTATIC SPEAKER CONNECTIONS measure the DC resistance between the output terminals with an ohmmeter. If the resistance is less than 3 ohms, the parts should be added as shown schematically in Fig. 2-5. When selecting connectors for the output lines, the following general precautions apply (with all power connectors): 1. A male plug, carrying signal, must not be on the far end of the line where it can be exposed, giving rise to both shock and short-circuit hazards.
16
2. Connectors which might accidentally cause the two
channels to be tied together during making and breaking of connection should not be used. A common example is the standard 3-circuit l/4 inch phone jack and plug when wired for stereo sound.
2. Connect output lines as per the following drawing, Figure 2-7. The output from the DC-3OOA in Mono is BALANCED and is isolated from the chassis, and from the input grounds to the DC-300A. CAUTION: Be certain that all equipment (meters, switches, etc.) connected to the Mono output lines is balanced. Both sides of the line must be totally isolated from the input grounds, to the DC-300A. If this is not observed, severe oscillation may result.
3. Connectors which can be plugged into AC power receptacles should never be used. 4. Connectors having low-current-carrying capacity
are "verboten."
5. Connectors having any tendency to short, or having
shorted leads, are unadvisable. Most commercially-available headphones employ a 3circuit l/4 inch phone plug which violates condition number 2. This is no handicap if a pad is inserted between the amp and jack, which is the only sensible thing to do, when such a large amplifier is coupled to such a small transducer. If this precaution is ignored, not only may the transducer be burned out but permanent hearing loss could result. The recommended pad is shown in Fig. 2-6.
lo
st.r.0 Earphenor
FIG. 2 - 6 SCHEMATIC OF EARPHONE PAD 2.4.1 MONO OPERATION A mono-stereo switch on the rear panel adjacent to the input jacks, allows the DC-300A to be operated normally (stereo) or in mono, with no internal modification. (See figure 2-2.) When in the mono position, the input circuitry of the DC-3OOA is changed so that the two amplifiers are "added" for mono output. (See mono specifications, page 3). Care must be taken in the external hook-up to assure proper operation. Proceed as follows:
1
FIG. 2-7 DC-300A MONO HOOK-UP
2.5 CONNECTING INPUT LINES
Connecting the inputs will require avoiding three basic dangers: Undesirable signals to the inputs, "ground loops," and feedback from output(s) to input(s). For loudspeaker-driving applications, the input should be free of any DC, as this could cause overheating of the loudspeaker voice coil. A simple visual test for DC on the inputs (providing the woofer is visible) is to slowly turn up the input level control with the amp on and watch for any displacement of the cone. If very much displacement is observed, the DC content of the input may be excessive and require a blocking capacitor. The graph of Fig. 2-8 indicates
The input line should be plugged into the channel 1 input jack. The level is adjusted with the channel 1 input level control. NOTE: The Channel 2 input jack and level control are not defeated in the Mono mode. However, the Channel 2 input should not be used in this mode. If a Channel 2 input is added to the Channel 1 input, distortion may result. If Channel 2 input is used alone, very low power output will result. For best results unplug the input to Channel 2 when operating Mono.
the effect of the size of the blocking capacitor on the
frequency response. Only a low-leakage type paper, mylar, or tantalum capacitor should be used for this purpose.
power line may provide this feedback path. Proper grounding, and isolation of inputs of common AC line devices is good practice. Refer to Section 4.2, par. 5 for
testing precautions. An extremely common form of this problem is encountered when using electrostatic loudspeakers or any other kind of load that is joined to the AC power mains. Capacitive coupling through the load's supplies may allow the amplifier's output to be fed through the AC mains and into the grounds of input equipment resulting in a system oscillation. To combat the problem, first try reversing the speaker leads on all channels if possible. If this does not solve the problem, try grounding the power amplifier to the AC ground with its 3 wire plug. (A ground loop may result through an FM tuner with an earth-grounded antenna
system when deploying the 3 wire plug. The use of ,005 UF disc capacitors in series with the FM antenna leads will eliminate thisproblem.)All hookup(interconnecting)cables should of course be as short as reasonably possible, and a turntable baseplate ground should always be broughtto the phono preamp with a separate ground wire, never via the input cable ground. If the oscillation still persists, start
TABLE FOR SELECTION OF INPUT DC BLOCKING CAPACITOR
If large amounts of ultrasonic or RF frequencies are found on the input, such as bias from tape recorders, etc., a lowpass filter should be placed on the input. While practicallyobtainable RF input levels will not damage the amplifier, they may cause burn-out of tweeters or other sensitive loads, activate the amplifier's protective systems, or cause general overload in the controlled-slewing-rate stage of the amp (which is employed to provide RF overload protection). The following filters are recommended for such applications.
removing input devices, working towards the amplifier until the oscillation disappears. This will identify the point of feedback. If an offending piece of equipment is found it should be inspected for unnecessary AC line-to-ground capacitances such as line filters, etc. If possible such should be removed. Such devices should never be found in the load, although it is true that some RF loudspeakers have used such filters to reduce RFI.
2.6 CONNECTING POWER
The amplifier is furnished with a three-wire AC plug as standard equipment. Adapters are readily available commercially for adapting this to a two-wire system if necessary. The amplifier offers five standard line-voltage connections: 100, 120, 200, 220, and 240VAC. The tag attached to the line cord indicates for which voltage the amplifier is connected. Most units are connected for 12OVAC. When changing the voltage to 200V or above, the external fuse, Fl, should be changed from 1 OA to 5A. Relabel the line tag to indicate the proper voltage. When testing the amplifier, the line voltage must be the peak equivalent to a sinusoid of the indicated line voltage when at full load. Line regulation problems can introduce serious errors in the measurements on an amplifier of this size. Only a competent technician should attempt alteration of the line voltage connections.
FIG. 2-9 LOW-PASS FILTER FOR SEVERE RF AT INPUTS A second problem area is "ground loops" - electronic
jargon for undesirable circulating currents flowing in a grounding system. A common form of loop (possibly resulting in hum in theoutput)isapairof inputcableswhosearea is subjected to a magnetic hum field. In practice, both cables should lie together along their length, and away from the power transformer. Tying the input and output grounds together may also form a ground loop. A third problem (with input and output grounds together, as in testing or metering) is feedback oscillation, from load current flowing in the loop. In industrial use, even the AC
In order to change the voltage, it is first necessary to carefully detach the bottom cover from the unit. On the back of the board-mount subchassis a terminal stripwith solder-
on jumpers is used to make the line-to-transformer primaries connections (see Fig. 2-10).
ALL VIEWS WITH BOTTOM PLATE REMOVED
1oov 120v
I
I
See Note
2oov 220 v
I
I
L
2 4 0 V See Note
I
I
1
NOTE: The 120V and 240V connections require the changeover of the RED wire from TB-3 to TB-2. Therefore the front panel, control circuit-board and shield must be carefully removed for access. When replacing shield, use care so that on-off switch locates properly in front panel opening!
FIG. 2-10 TABLE OF LINE VOLTAGE CONNECTIONS
Section 3
3.1 CONTROLS AND ADJUSTMENTS
OPERATING INSTRUCTIONS
OPERA TING CONTROLS The DC-300A contains all the facilities essential for a
high performance amplifier. 3.2 THE PROTECTION MECHANISMS
On the front panel are located independent level controls,
a power switch, and pilot light. There is an AC line fuse on the rear of the unit. The level control should be adjusted for the desired amplifier gain or output level. When the control is fully CW, the gain is 26db as determined by precision 1% resistors in the DC-300A's feedback loop. The DC balance controls located behind the front panel seldom, if ever, need adjustment. Only in the most critical applications will they need adjustment (not "hi_fi" or similar applications). To adjust the DC balance controls, use the following procedures (see Circuit Board layout in Section 4):
The DC-300A is protected against all the common hazards which plague highpower amplifiers, including shorted, open, and mismatched loads; overloaded power supplies; excessive temperature; chain destruction phenomena; input overload damage; and high frequency overload blowups. Protection against shorted and low impedance loads is provided by the Signal Programmed Automatic Current Executor (SPACE control). It functions as an automatic current limiter at audio frequencies whose value of current limiting threshold is dependent on the history of the output signal. Output current causes the threshold to decrease while output voltage causes the threshold to increase. The no signal threshold is high enough to allow tone bursting, (even into 4 ohms) without premature limiting as is found in some recent products of other manufacturers Since the limiter has no instantaneous response to output voltage, flyback transients do not appear in the output w h e n l i m i t i n g o c c u r s o n i n d u c t i v e l o a d s . Flyback transients are a necessary response of a VI limiter (sometimes misnomered an "Energy Limiter") when limiting drive to an inductive load. The actual response of the flyback pulse is that the amplifier yields to the load resulting in a pulse emanating from the load which returns the inductive energy of the load to the opposite polarity power supply of the amplifier as that supply that produeed the excessive output. The audible effect of flyback pulses is to produce a rasping, popping s o r t of sound which is not pleasing.
1. Make sure amp has been allowed at least 15 minutes
of warm-up.
2 . Set corresponding level control fully CCW. 3 . Remove input signal from corresponding input. 4 . Place sensitive DC voltmeter across output. 5 . Adjust output balance control using small flatbladed screwdriver for zero reading on voltmeter.
6 . Turn level control CW to 12 o'clock. 7 . A d j u s t i n p u t b a l a n c e c o n t r o l u s i n g s m a l l flatbladed screwdriver for zero reading on voltmeter. The DC balance controls are now adjusted.
19
A current limiter will not yield to the load butwill sustain the constant current demands of the inductive load without flyback. Early amplifier designs frequently employed fixed current limiters but had serious difficulty with obtaining reliable low frequency output while being capable of full-voltage 4 ohm output. Also, many earlier designs used fragile epibase or triple diffused outputs, which for reliable performance are poor mates for a current limiter protection scheme. The DC-3OOA uses eight 150W silicon power transistors per channel, chosen for their combination of
current, voltage and response characteristics to allow wide operating safety margins. The safe operating area of each transistor is specified by the manufacturer and individually tested by CROWN. Their toughness allows the reliable use of a current limiter which when rendered signal variable permits larger power outputs than would be safely allowable with a current limiter of fixed type. At subsonic frequencies, the SPACE control behaves as a VI limiter and provides the increased protection needed at DC to prevent destruction due to heat buildup in the half of the output stage that is being driven.
The fuse inherently protects the power supplies against overload. The AC line for 100, 120VAC is fused with a 1 OA 250V type A6 fuse (on 200, 220, 240VAC, 5A type MTH 250V). The use of any other size fuse will invalidate the warranty. Never change fuses with power applied! On each heat sink (see Fig. 2-2) is mounted a thermal switch which protects the amplifier against insufficient ventilation. If either heat sink becomes too hot, the AC line power will be interrupted until the temperature falls to a safe level, whereupon power will be automatically restored. When such an event occurs, the external symptoms are: no indication of AC power (by the pilot), and a warm front panel. All of the amplifier's voltage-amplifier circuitry is designed to be inherently current-limited. Thereby, if any of the devices should fail, (which is extremely unlikely), no damage will occur to the rest of the stages. The input stage is protected against overdrive damage by a series limiting resistor should the input signal level ever become very excessive. The amplifier features a controlled slewing-rate which, coupled with the SPACE controller, protects the amplifier from blowups when fed large RF input signals.
Such operation may damage the device and/or needlessly waste output power. 4. Do not short the ground lead of an output cable to the input signal ground as oscillations may result from forming such a ground loop. 5. Never remove fuses with power applied.
6. Operate and fuse the amplifier only as set forth in Section 3.2. 7. Operate the amplifier from AC mains of not more than 10% above the selected line voltage and only on 50, 60, or 4OOHz AC. Failing to comply with these limits will also invalidate the warranty. 6. Never connect the output to a power supply output, battery, or power main. Damage incurred by such a hookup is not covered by the warranty. 9. Do not expose the amplifier to corrosive chemicals such as soft drinks, lye, salt water, etc.
10. The amplifier is not recommended for high power
industrial usage at frequencies above 20KHz.
11. Tampering in the circuit by unqualified personnel
or the making of unauthorized circuit modifications invalidates the warranty
12. Do not expose the output leads to areas likely to be 3.3 OPERATING PRECAUTIONS
The following are a number of operating precautions given as an aid to understanding proper and improper amplifier usage: 1. Use care in making connections, selecting signal sources, and controlling the output level. The loudspeaker you save may be your own. CROWN is not liable for any damage done to loads due to careless amplifier usage or deliberate overpowering (CROWN sperkers excepted). For pointers on load protection see Section 3.4. 2. Never parallel the two outputs by directly tying them together or parallel them with any other amp's output. Such connection does not result in increased power output. Damage incurred by such operation is not covered by the warranty. 3. Never drive a transformer-coupled device or any other device which appears as a low frequency short (less than 3 ohm) without a series isolating capacitor. struck by lightning. Such an installation could invalidate the amplifier.
3.4 LOAD PROTECTION METHODS
The most common of all load protection schemes is a fuse in series with the load. The fuse may be single, fusing the overall system. Or, in the case of a multiway speaker system, it may be multiple with one fuse on each speaker.
Fuses help to prevent damage due to prolonged overload, but provide essentially no protection against damage that may be done by large transients and such. To minimize this problem, high-speed instrument fuses such as Littlefuse 361000 series are most appropriate for such applications. For a nomograph showing fuse size vs. loudspeaker ratings refer to Fig. 3-3.
400 300
t 200
--7
A common problem which causes damage and irritation is the turn-on thump problem typical to many signal sources. Fig. 3-5 shows the schematic of a muter which, when inserted in the input signal line, mutes for several seconds before connecting the source to the amplifier, thereby eliminating turn-on transients. It also removes turn-off transients occurring after the relay drops open (=O.l sec.).
Emmpl.: z:sn AllStir:
a-9 --10 l--
N " a W;;
d--
..14 y E
2 ; .; IL.4-.a-
43 ..16 g UJ e-20
..25 --30
.2- .15..
.l---At3 .oa-
FIG. 3-3 FUSE SELECTOR NOMOGRAPH FOR LOUDSPEAKER PROTECTION Another form of load protector is shown schematically in Fig. 3-4. Whenever the load is overdriven, a relay switches a lamp in series with the load, smoothly relieving the overload. The lamp then doubles as an overdrive indicator as it glows. If overdrive is unreasonably severe, the lamp will serve as a fuse. By adjusting the relay tension adjustment and the protection level control, this system is useful from 25 to 200 watts for a typical 8 ohm load.
FIG. 3-5 TURN-ON- TRANSIENT MUTER FOR LOAD PROTECTION
3.5 CLEANING
The CROWN DC-3DDA has a rugged anodized front panel for life-time service. The panel can be cleaned with a moist cloth and mild detergent. Never use steel wool, scouring powder, lye solution, or any strong abrasive cleaner as these will damage the panel's finish. The back chassis should require no more cleaning than periodic dusting with a clean dry cloth. The use of detergents, abrasives or other cleaners may remove the fine film of oil from the black anodized chassis which is used to increase its surface lustre.
to
Load
FIG. 3-4 RELAY CONTROLLED PROTECTOR WITH 0 VERLOAD INDICA TOR
Section 4
CIRCUITRY
4.1 PRINCIPLES OF OPERATION
The DC-300A has two totally direct-coupled amplifier circuits which employ a dual IC op amp and silicon transistors in all stages. The CROWN-designed and developed circuit represents a level of quality and performance presently unequaled in the field of audio amplifier design. As is implicit in the term "totally direct-coupled," the DC300A has a perfectly flat frequency and phase response extending to OHz or DC. Flat to DC response results in not only low frequency amplification with absolutely no phasedistortion, but also in perfect overloadcharacteristics. Nonsymmetrical waveforms (such as music) cause overload thumping in all currently produced AC amplifiers. These same amplifiers may, however, show no signs of thumping when fed a symmetrical test waveform such as a sinusoid. DC frequency response combined with ultra-low noise and IM distortion results in the closest approach to a "straight wire with gain." Another characteristic of a DC amplifier is the thump or pop produced at turn-on and turn-off. For example, at turn-on the input amplifier requires a finite period of time to reach operating levels. During this time the output could be driven to large DC offsets resulting in annoying thumps. A supply voltage detector virtually eliminates this problem in the DC-BOOA. The detector disconnects the regulated supply voltages to the output stages during these turn-on and turn-off periods, thus not allowing the DC offsets at the output to occur. The dual IC op amp is of a low noise type having a large gain bandwidth. The result of using it for the input voltage amplifier is that a maximum amount of feedback is applied reducing distortion to record low values. This has been confirmed by measurement with an elaborate test setup employing CROWN-developed solid-state variable filters and wave analyzing equipment. No other presently available harmonic distortion test apparatus is capable of such low residuals. The 300A's low distortion is achieved by employing multiple feedback loops to allow a maximum of total feedback. The lack of noise is evidenced by a typical 20Hz-20KHz effective input noise of 1.25~ volts which produces an effective 8 ohm output of 80 micro-micro (pica) watts. The output stage is a quasi-complementary format employing the CROWN class AB+8 technique which uses no bias current in the output transistors. The result is maximum efficiency with minimum crossover notch distortion and amplifier idling-heat. Thus there is no bias current adjustment, as the output circuit is not temperature-tolerance critical. Temperature drifts of bias are further controlled by bias servos which are mounted on the heat sinks. In the AB+8 output circuit, the driver transistors carry the bias current, while the output transistors serve only as boosters. The output transistors (12OOW dissipation/Ch) sensewhen the driver transistors are delivering significant current to the load and take over and deliver the large load currents. Protection against shorted and low impedance loads is provided by the CROWN-developed SPACE (Signal Programmed Automatic Current Executor) control circuit. It functions as an automatic current limiter at audio frequencies and as a VI limiter at subaudio frequencies. The threshold of current limiting is dependent on the history of the signal, yet the no-signal threshold of current limiting is high enough to allow full power tone bursting. The net result is total protection with a maximum of headache-free output power requiring neither an inventory of special fuses or cumbersome load matching techniques. The monolithic input amplifier stages result in extremely low DC drift. The input terminal bias current is offset by a unique temperature compensated source resulting in a laboratory amplifier needing no user-accessible offset controls. The input amplifiers are powered by zener-regulated power supplies. The bias regulators are also powered by zenerregulated current sources with the result that line voltage variations do not cause noise or distortion due to misbiasing. The power supply is a continuous-duty type, capable of 1 KW loading. The power transformer, weighing 25 pounds, is constructed of special grain-oriented steel. The main DC supplies arefull-wavecapacitor inputtypewith heavy-duty, chassis heat-sinked diodes. Computer grade electrolytics furnish over 48 joules of energy storage. A higher voltage at low current is derived from a half-wave voltage-doubler circuit. This voltage is used in the amplifier's driver circuit. The DC-300A represents nothing short of the highest quality in both circuitry and components. It should provide a lifetime of trouble-free service for the most discriminating users.
23
24
4.2 TEST PROCEDURES
The sole function of this section is to list precautions essential to obtaining accurate measurements when dealing with high-power, high-purityamplifierssuch astheDC300A.
8. Residual distortion and noise levels should be fully known for all the test equipment in order to accurately evaluate the amplifier. 9. Never attempt to measure damping factor by placing abnormal loads on the output. D-F measurements taken during clipping, or any other form of overload, are meaningless. The preferred method is to apply an externally generated current to the output terminals and measure the resultant voltage at the terminals. A convenient current is one ampere - as the resultant voltage will read direc;ly in ohms for [Zd. Damping Factor is defined as , where IZLI is typically 8 w ohms. A convenient gengrator for the 1A current is that amplifier channel not under test. A non-inductive resistance of 8 ohms - coupled between both channels' output terminals -will provide 1A when 8 volts are impressed across the resistor (by that channel not under test). 10. Never measure hum and noisewhen in the presence of strong magnetic fields. The amplifier should be at least 4 inches away from any large metallic objects or shield plates for a reading to be meaningful. 11 Noise measurements should be taken with a bandpass filter of 20.20KHz. For audio purposes the measurement of noise above 20KHz is meaningless.
1. Use the proper line voltage, which is the one for which
the amplifier is connected. The voltage should be measured throughout the testing with a peak reading meter, and adjusted to the RMS equivalent voltage (to compensate for line voltage regulation errors during the course of the measurements). All measurements should be taken at the power amplifier's plug. When testing for IHF music-power measurements, the line voltage is to be set at 12OV when the amplifier is connected to 12OV, (IHF standards). If the amp is connected otherwise, the equivalent test may be given by applying the appropriate voltage. 2. The load should be resistive, having less than 10% reactive component at any frequency up to five times the highest test frequency. The resistor should be capable of continuously dissipating the full output of the amplifier while maintaining its resistance within 1% of its rated value. The load should employ only highcurrent connectors (if any), and be connected to the binding-post output terminals. All output measurements should be taken at the amplifier output terminals, and not anywhere along the output cable through which the load current is flowing. 3. The input level controls should be set to maximum for all distortion tests to assure repeatability of all measurements. 4. When measuring hum and noise, all inputs should be disconnected from the amplifier and the level controls set to minimum or to maximum, preferably minimum. 5. Whenever possible avoid ground loops in the test equipment caused by connecting the output ground to the input ground. Never connect the ground of the cable going to the load back to the input ground. Ground loops are especially obnoxious when measuring distortion. An I-M distortion analyzer, for example, has its input and output terminals tied to a common ground. Such a test should use an ungrounded output return, with the output lead(s) wrapped around the well-shielded and grounded input cable. 6. Always monitor the test oscillator when measuring frequency response. Use a wide-band AC voltmeter; or use the same meter for both input and output level measurements, if the meter's frequency response is known not to be dependent on attenuator settings. 7. Accuracy in measuring voltages for computing wattage is critical. For example, a 2% voltage error together with a 1% resistance error can result in an error of lOwatts power into 8 ohms.
4.3 SERVICE
Should service other than routine fuse replacementever be required, it is recommended that the unit be returned to the factory in the original packing (or replacement, if damaged). For warranty service the machine must be returned to the factory or warranty service station. The CROWN warranty is detailed on page 12. Because of the level of circuitry sophistication of the DC300A, only the most competent technicians should be allowed to service it. Many of the parts are standard items stocked by most supply houses. However, there are several which appearto
be standard parts but are actually different. Although standard parts may be used in an emergency, best results will be with factory parts. A number of the parts are available only from CROWN. When ordering parts, be sure to give the amplifier serial number as well as the part number and description. Rated firms will be billed, otherwise shipments will be C.O.D. Before returning an amplifier to the factory for service, authorization should first be obtained from the service manager. Shipments may be sent UPS or truck freight, prepaid and insured at total value. The factory will return your serviced unit by UPS or truck freight, collect. and will add C.O.D. charges in the event that the cost is not covered by registered warranty.
Section 5
APPLICATION NOTE NO. 1 V-l LIMITS OF A LOAD
Evaluating the V-l (volt-ampere) needs of a load: Many loads exhibit large reactances (or energy storage), which limits a power amplifier's ability to deliver a maximum power. If a load stores energy, which in turn flows back into the amplifier, it is clear that the maximum power efficiency of the system is not being achieved. Power that flows back into a linear amplifier must necessarily be dissipated in the form of heat. A pure reactance is not capable of dissipating any power; therefore to drive such a load would only cause power amplifier heating. In practice all loads exhibit some energy dissipation however large their energy storage characteristics may be. The ideal coupling to any load is one that optimizes the desired dissipation component while minimizing the reactive or stored-energy component that is seen by the amplifier's output terminals.
APPLICATION NOTES
In applications where the input is sinusoidal and of small proportional frequency deviation, a relatively stable load may be resonantly tuned to present a real value of impedance to the amplifier. Any load, no matter how complex its behavior, has a V-l operating range which may be mapped by the following test. The maximum voltage and amperage excursions in all directions about zero (center of scope screen) define the volt-ampere operating range of the load. If a load is known to be linear over its operating range it is not necessary to supply the maximum desired power to the load. The test may be conducted at low signal levels and the current-sensing resistor (indicated as 0.1 ohm) may be enlarged to a convenient value for the oscilloscope's deflection sensitivity. The resulting plot may be then linearly scaled to the desired operating level.
AMPLIFIER LIMITS OF VI OUTPUT Vout
cl
scope
LOAD under ted
. . . AC LINE F"SE
CHANNELS EDUALLY
- - MID-FREDVENCY
BURST
LIMIT
BLOWS [DC SINGLE CHAN.l SLOWS AT 10A DC IF BOTH ARE DRIVEN
X
SHORT CIRCUIT CONTINUOUS LIMIT A R EA OVER WHICH LIMITER (AC) "ARIES (SIGNAL DEPENDENT)
-MAX
AC
LIMIT
It`, V
O U T ISINEI
AT
MAX.) - MAX. CONT. AC POWER ,ZA = 2.75*) HlGH FREDVENCY
Note: Scope and amplifier grounds are not common.
-
-
-
-
LIMIT
Vertical input reads (-) amperes vertically. If scope has an inverter, invert to read (+) A. 25
APPLICATION NOTE NO. 2 VFX-2
The CROWN VFX-2 is a dual-channel variable electronic filter-crossover. When used with a power amplifier it can greatly add to the total system capability. In combination with the DC-300A, the VFX-2 adds several convenient useful functions. The connections are made with the VFX-2 quickly and easily. If a balanced line is to be used with the unbalanced input of the DC-300A. the VFX-2 can serve asthe interface. While maintaining these functions the output can be shaped by selecting variable high-pass, lo-pass, or bandpass filters. As a filter, the VFX-2 can be used as a crossover or ahead of several amplifiers in a bi- or tri-amped system. Overall noise and distortion are extremely low, with IM distortion less than .Ol% at rated output (2.5V into 600 ohms), and noise more than 1 OOdl3 below rated output with OdB gain. For further information please request the VFX-2 specification sheet or for a nominal fee, purchase a VFX-2 instruction manual.
29
APPLICATION NOTE NO. 3
WARNING POWER AMPLIFIER PROTECTION SYSTEMS PROTECTAMPLIFIERS BUT NOT SPEAKERS! YOU, AND/ OR YOUR SPEAKER MANUFACTURER ARE RESPONSIBLE FOR SPEAKER PROTECTION!
Except in unusual sets of circumstances, the circuitry included in power amplifiers designated as "protection", whether made up of transistor limiters, circuit breakers, fuses, SCR's, or whatever, is designed primarily to protect the amplifier from damage and will only protect speakers incidentally. There are some exceptions to this rule, which allow the user to vary the output power limits of his amplifier to match the power rating of his speakers Even this, however, is a far from perfect speaker protection scheme. The reason why this holds true is simple: each make or model speaker has its own unique operating capabilities. As a rule, a speaker system (including all electronics parts such as crossover parts and electrostatic element transformers, as well as voice coils) will be able to drssipate a certain amount of power continuously without burning up. This depends on the size, quality, configuration, etc., of those parts. The same speaker will be able to handle a somewhat hrgher power level for a short period of time (in the millisecond range) without being destroyed by heat, but may then be endangered by such phenomena as extending moving elements beyond their normal range of travel (bottoming, torn diaphragm, etc.), overvoltaging electrostatic panels (arcing), or other such suddenly disabling events. Since the points at which these disastrous happenings will occur, differ for different speakers, a speaker protection system must be completely adjustable if it is to be useful for more than a narrow range of speakers. Furthermore, if the user is to be able to do adequate adjustment on a protection system external to his speakers, he must receive accurate information about the speaker power handling capabilities from the speaker manufacturer. Speaker protection systems embodied in amplifiers are comparatively useless, therefore, unless the following things are true: (1) The protection system can be accurately adjusted by the user. (2) The power handling capabilities of the speakers are clearly stated by the manufacturer. (3) The information about the speaker protection and speaker power handling are stated in common terms so that the user can adjust the protection properly for the speaker. These three things are rarely true simultaneously. It is for this reason that CROWN takes the approach that speaker protection is the responsibility of the speaker manufacturer. Amplifier manufacturers have long been required to provide protection in their products for any faults occuring externally to the amplifier outputs, such as speaker short circuits, open circuits, etc. In order to
fairly share the responsibility, and since the protection cannot be exhaustively provided any other way, we feel that speaker manufacturers should provide protection tailored to their individual products. At CROWN we have done this with our own speakers, simply because it is the only comprehensive means of providing worthwhile protection for all of our speakers. Increasing power available from modern amplifiers increases the danger of speaker damage. Although occasionally an internal amplifier malfunction can contribute to speaker failure, it is much more likely that speakers will be overpowered by inadvertant use of too much power. In the absence of internal protection in most speaker systems, CROWN recommends very strongly that in-line speaker fuses be employed in all systems. The fuse selection nomograph reprinted in each CROWN amplifier manual can be an invaluable help in choosing fuses of the proper size. However, the effectiveness of fuses in protecting speakers is limited in two important ways (1) Fuses as a rule protect only against prolonged overpowering, and can only prevent speakers from being driven with more than their RMS or average power rating. Fuses cannot protect against sudden high level transients of short duration. The use of high-speed instrument fuses will give the best protect