Text preview for : 81204302.pdf part of panasonic cs-g123ke i have some code indicated F99 and the air conditioning stop i think this might be same model,it shows the fault codes at the end i think



Back to : PANASONIC CS-G93KE_PDF SE | Home

CS-G93KE

Functions
Remote Control

OFF / ON L

Operation OFF / ON

TEMP

Room Temperature Setting
· Temperature Setting (16°C to 30°C).

MODE

Operation Mode Selection
· · · · ·
a HEAT COOL DRY FAN

TIMER ON OFF

Automatic Operation Mode Heating Operation Mode Cooling Operation Mode Soft Dry Operation Mode Fan Operation Mode

Timer Operation Selection
· 24-hour, OFF / ON Real Timer Setting.



Time / Timer Setting
· Hours and minutes setting.

POWERFUL

Powerful Mode Operation

SET CANCEL

Timer Operation Set / Cancel
· ON Timer and OFF Timer setting and cancellation.

FAN SPEED

Indoor Fan Speed Selection
· h j k l · h j k ll · h j k lll · h j k llll · h j k lllll · AUTO FAN Low Medium­ Medium Medium+
SLEEP CLOCK

Clock Setting
· Current time setting.

High Automatic Fan Speed
WIDE/ SPOT

Sleep Mode Operation OFF / ON

AIR SWING

Airflow Direction Control
· · Vertical Airflow Direction Control
AUTO

WIDE / SPOT
POWERFUL
POWER SLEEP TIMER
HIGH

P O W E R LOW MONITOR

WIDE Horizontal Airflow Direction SPOT Horizontal Airflow Direction

Automatic Control · Manual Control
POWERFUL
POWER SLEEP TIMER
HIGH

P O W E R LOW MONITOR

· Horizontal Airflow Direction Control
AUTO

Automatic Control Manual Control
­2 ­

CS-G93KE

Functions
Indoor Unit

FOR ALL OPERATIONS
POWER L

Power Switch OFF / ON L

Power Monitor Display *
· Lights up during compressor operation.

AUTO OFF / ON

Automatic Operation Switch
· Used when the remote control cannot be used.

Operation Mode
· Automatic, Heating, Cooling, Soft Dry and Fan Operation.

Remote Control Signal Receiving Sound Control OFF/ON *
· It can be controlled by pressing Automatic Operation Switch for 10 seconds.
TEST RUN OFF / ON

Automatic Restart Control *
· Operation is restarted after power failure at previous setting mode.

Test Run Operation
· Used when test running or servicing. · Compressor operation: rated frequency Cooling: 50Hz (CS-G93KE), 70Hz (CS-G123KE) Heating: 71Hz (CS-G93KE), 90Hz (CS-G123KE)

Sleep Operation Mode *

Timer Operation *

Operation Indication Lamps
· ­ Lights up in operation, blinks in Automatic Operation judging and Hot Start operation. · TIMER (Orange) ­ Lights up in Timer Setting. Blinks in Self Diagnosis Control. · SLEEP (Orange) ­ Lights up in Sleep Mode Operation. · POWERFUL (Orange) ­ Lights up when Powerful mode is selected
POWER

Powerful Mode *
· For quick cooling or heating

(Red)

Indoor Fan Speed Control *

Airflow Direction Control *

­3­

CS-G93KE

CS-G93KE

CS-G93KE

Functions

Functions

Functions
Outdoor Unit

COOLING/SOFT DRY OPERATION Room Temperature Control *
Compressor Operation Frequency Operation Mode CS-G93KE Cooling Soft Dry Heating 15 ­ 64 Hz 15 ­ 22 Hz 15 ­ 99 Hz CS-G123KE 15 ­ 92 Hz 15 ­ 22 Hz 15 ­ 115 Hz

HEATING OPERATION Anti-Cold Draft Control *

AUTOMATIC OPERATION Outdoor Fan Motor
· 6 poles induction motor, 1 speed.

Deodorizing Control *

Low Frequency Operation Protection *

Sensible Heat Control *

Hot Start *

FAN OPERATION Time Delay Safety Control * Minimum Frequency Operation Protection *

Anti-Fog Discharge Control *

Intake Air Temperature Control * Forced Operation 30 seconds * Outdoor Air Temperature Control *
· Detect outdoor ambient temperature and limits compressor operating frequency

Temperature Shift *

Anti-Dew Formation Control *

High Pressure Control * High Pressure Control * (For Cooling/Soft Dry) Standby Control * DC Peak *

Self Diagnosis *

Anti-Freezing Control *

Low Pressure Control * (Gas Leakage Detection)

Quiet Operation *

Deice Operation *

Standby Control *

Total Running Current Control * Low/High Power Supply Voltage Protection *

Deice Operation *

Compressor Overheating Protection *

Indoor Power Relay Control * IPM (Power Transistor) Overheating Protection *
* Details can be refered to OPERATION DETAIL in this manual.

­4­

­5­

­6­