Text preview for : 81204302.pdf part of panasonic cs-g123ke i have some code indicated F99 and the air conditioning stop
i think this might be same model,it shows the fault codes at the end i think
Back to : PANASONIC CS-G93KE_PDF SE | Home
CS-G93KE
Functions
Remote Control
OFF / ON L
Operation OFF / ON
TEMP
Room Temperature Setting
· Temperature Setting (16°C to 30°C).
MODE
Operation Mode Selection
· · · · ·
a HEAT COOL DRY FAN
TIMER ON OFF
Automatic Operation Mode Heating Operation Mode Cooling Operation Mode Soft Dry Operation Mode Fan Operation Mode
Timer Operation Selection
· 24-hour, OFF / ON Real Timer Setting.
Time / Timer Setting
· Hours and minutes setting.
POWERFUL
Powerful Mode Operation
SET CANCEL
Timer Operation Set / Cancel
· ON Timer and OFF Timer setting and cancellation.
FAN SPEED
Indoor Fan Speed Selection
· h j k l · h j k ll · h j k lll · h j k llll · h j k lllll · AUTO FAN Low Medium Medium Medium+
SLEEP CLOCK
Clock Setting
· Current time setting.
High Automatic Fan Speed
WIDE/ SPOT
Sleep Mode Operation OFF / ON
AIR SWING
Airflow Direction Control
· · Vertical Airflow Direction Control
AUTO
WIDE / SPOT
POWERFUL
POWER SLEEP TIMER
HIGH
P O W E R LOW MONITOR
WIDE Horizontal Airflow Direction SPOT Horizontal Airflow Direction
Automatic Control · Manual Control
POWERFUL
POWER SLEEP TIMER
HIGH
P O W E R LOW MONITOR
· Horizontal Airflow Direction Control
AUTO
Automatic Control Manual Control
2
CS-G93KE
Functions
Indoor Unit
FOR ALL OPERATIONS
POWER L
Power Switch OFF / ON L
Power Monitor Display *
· Lights up during compressor operation.
AUTO OFF / ON
Automatic Operation Switch
· Used when the remote control cannot be used.
Operation Mode
· Automatic, Heating, Cooling, Soft Dry and Fan Operation.
Remote Control Signal Receiving Sound Control OFF/ON *
· It can be controlled by pressing Automatic Operation Switch for 10 seconds.
TEST RUN OFF / ON
Automatic Restart Control *
· Operation is restarted after power failure at previous setting mode.
Test Run Operation
· Used when test running or servicing. · Compressor operation: rated frequency Cooling: 50Hz (CS-G93KE), 70Hz (CS-G123KE) Heating: 71Hz (CS-G93KE), 90Hz (CS-G123KE)
Sleep Operation Mode *
Timer Operation *
Operation Indication Lamps
· Lights up in operation, blinks in Automatic Operation judging and Hot Start operation. · TIMER (Orange) Lights up in Timer Setting. Blinks in Self Diagnosis Control. · SLEEP (Orange) Lights up in Sleep Mode Operation. · POWERFUL (Orange) Lights up when Powerful mode is selected
POWER
Powerful Mode *
· For quick cooling or heating
(Red)
Indoor Fan Speed Control *
Airflow Direction Control *
3
CS-G93KE
CS-G93KE
CS-G93KE
Functions
Functions
Functions
Outdoor Unit
COOLING/SOFT DRY OPERATION Room Temperature Control *
Compressor Operation Frequency Operation Mode CS-G93KE Cooling Soft Dry Heating 15 64 Hz 15 22 Hz 15 99 Hz CS-G123KE 15 92 Hz 15 22 Hz 15 115 Hz
HEATING OPERATION Anti-Cold Draft Control *
AUTOMATIC OPERATION Outdoor Fan Motor
· 6 poles induction motor, 1 speed.
Deodorizing Control *
Low Frequency Operation Protection *
Sensible Heat Control *
Hot Start *
FAN OPERATION Time Delay Safety Control * Minimum Frequency Operation Protection *
Anti-Fog Discharge Control *
Intake Air Temperature Control * Forced Operation 30 seconds * Outdoor Air Temperature Control *
· Detect outdoor ambient temperature and limits compressor operating frequency
Temperature Shift *
Anti-Dew Formation Control *
High Pressure Control * High Pressure Control * (For Cooling/Soft Dry) Standby Control * DC Peak *
Self Diagnosis *
Anti-Freezing Control *
Low Pressure Control * (Gas Leakage Detection)
Quiet Operation *
Deice Operation *
Standby Control *
Total Running Current Control * Low/High Power Supply Voltage Protection *
Deice Operation *
Compressor Overheating Protection *
Indoor Power Relay Control * IPM (Power Transistor) Overheating Protection *
* Details can be refered to OPERATION DETAIL in this manual.
4
5
6