Text preview for : CF2001PE.pdf part of KONICA MINOLTA CF 2002 KONICA MINOLTA CF 2002 Program obsługi serwisowej do kopiarki / drukarki KM CF 2002



Back to : CF2001PE.pdf | Home

CF2001P/PE
Training Material

ˇ This training material contains information only on the modifications made in the CF2001P/PE as compared with the CF2001. The controller portion is the same controller as used with the CF2001 (Fiery X3e). ˇ For any information not covered herein, please refer to the CF1501/2001 Modules 1, 2 & 3 in PDS. ˇ The numbers marked with an asterisk (*) in a slide indicate that the specific details of that particular statement are given in a linked document.

Contents
1) Overview 2) Installation/Set-Up 3) Operation 4) Field Service 5) System Control Block Diagram

1) Overview

1-1 Concept 1-2 System 1-3 Specifications

1-1 Concept
A high-speed full-color printer offering high image quality and outstanding functions to meet the needs of high Print Volume office users demanding high-speed color printing.
Points of advantage over the competition:
ˇ Controller with a resolution of 600 dpi and a gradation level of 8 bits/dot. ˇ Printer engine capable of multi-valued exposure equivalent to a writing resolution of 600 x 1,800 dpi.

1-2 System
1 2 3 4 5 6 7 8 9 10 11 12 13 14 Engine (#4004)
250MPC/500UC

Fiery X3e I/F kit I JS-1002 FN-107 FN-108 AD-14 Copy desk Copy table Paper Feed Unit
Large Capacity Cabinet Dehumidifying heater Mechanical counter

CF2001P/PE basic configuration (1)
Options for paper exit sections

I/F kit I Control panel Cooling-air duct 2 3 12

Options for paper feeding section

DT-105

Other options

7 1
Engine 250MPC 500UC

13 14

Fiery X3e

4 5 6

8

10 10

500UC 500UC

11

2500LCC

9

1-3 Specifications
Main Unit Specifications Reliability specifications Print Volume (Copies/Month)
Color Average Range Max 5k 1.55 k 30 k Black 1k 0.51 k
[ k = 1000 copies ]

Print Mode
Black and white

Color
Making two prints per job (2P/J)

Standard Mode Color ratio

Making two prints per job (2P/J)

6%

5% for each color

2) Installation/Setup
(*1) Copy Table Copy Desk FN-107
PF-117

FN-108

JS-1002

PF-118

ˇMechanical Counter ˇDT-105
Fiery X3e for CF2001

Dehumidifying Heater for PF-118 and Copy Desk

Dehumidifying Heater for PF-117

AD-14 Printer Engine Section

Interface Kit

Links to Related Materials
The Service Jigs Software and adjustment service jigs are necessary when installing the CF2001P/PE, PF-117, PF-118, AD-14, and FN-107/108. (*1)

CF2001P Set-Up Instructions
Clicking any one of the following buttons allows you to access the PDF set-up instructions for the corresponding unit. (These documents represent the same set-up instructions as those for the options of the CF1501/2001.)

PF-117 PF-118 Copy Table / Copy Desk AD-14

I/F Kit I JS-1002 FN-107/FN-108 Notes on Slides

Adjustment Service Jigs List
Parts supplied by Minolta Parts arranged by subsidiary/distributor (commercially available)

Service Jigs Software
(*1) Jig Harness (4004-7838-01) (*2) RS232C Serial Cables

422 to RS 232C Level Converter (*3)

PC (*4)

X-Rite DTP32/41

RS 232C Selector

CF2001P Set-Up
This section explains how to set up the Service Jigs Software and adjustment service jigs, and precautions for X-Rite calibration. Clicking [CF2001P Set-Up Instructions] on Slide 8 (Links to Related Materials) will allow you to access the corresponding PDF data.

ˇ ˇ

Setting up the Service Jigs Software and adjustment service jigs ( Setup Instructions P.13) Procedure to turn ON the Power ˇ Procedure to turn OFF the Power Switch of the Machine (*1) Switch of the Machine (*1)
1. Access the initial screen of the Service /Software. 2. Make sure that the control panel shows "Info." 3. Shut down the Service Jigs Software. 4. Shut down the Fiery X3e.

1. Set up the Level Converter. 2. Connect cables. 3. Turn ON the Level Converter and X-Rite. 4. Turn ON the PC and start the Service Jigs Software. 5. Turn ON the Power Switch of the machine.

5. Turn OFF the Power Switch of the machine. 6. Turn OFF the Level Converter and X-Rite. 7. Remove the cables. (*2) .

Level Converter and Selector
Setting the Level Converter
ON

Turn ON the TERM switch (S2). No other switches should be changed. Remove one screw and the cover. Setting the Selector Apply the aluminum tape on both ends properly as illustrated below.

Remove two screws and the cover.

Apply the aluminum tape shipped with the Jig Harness. (*1)

Connecting Cables (p. 1 of 2)
Connecting Cables
Jig Harness RS232C Serial Cables

ˇOverall Setup
Switch Box
B C A

X-Rite PC Converter

CF2001P

NOTE: The Serial Port of the X-Rite should be set to 19,200 bps.

Connecting Cables (p. 2 of 2)
ˇMaking Connections
Switch Box X-Rite PC
B C A

B : X-Rite

C : PC

A : Converter

Converter

CF2001P

Attach the ground wire to connector.

Brown

Red

Orange

Blue

Loosen the screws on the terminal board.

Install four Jig Harnesses in the terminal board. (*1)

Tighten the screw on the terminal board.

X-Rite Calibration (p. 1 of 3)
X-Rite Calibration ( Setup Instructions P.14)
Set up the Service Jigs Software and adjustment service jigs. At this time, make sure that the selector on the Switch Box is in the A position (PC position), and that the Service Jigs Software is installed on the hard drive. DO NOT run it from the CD-ROM.
Turn ON the PC and START the Service Jigs Software. Turn ON the Power Switch of the machine. (The LCD turns ON.) (*1)

Press the Utility key, and select Meter Count. Using the numeric keys, press Stop 0 0 Stop 0 1 in that sequence to enter the Tech. Rep. Mode.

X-Rite Calibration (p. 2 of 3)

(*1)

Press the Start key to let the printer produce four test pattern prints.

(*3)

(*2)

Press the Start key.

X-Rite Calibration (p. 3 of 3)
Test pattern scanning screen
(*1) (*2)

X-Rite guide position

Test pattern scanning position 2 edge 2 center

Position for two edge rows

Position for two central rows

B D C A Test pattern Cyan

3) Operation
3-1 Utility 3-2 Tech. Rep. Mode

Operations are performed on the control panel for CF1501/2001. With CF2001P, the Service Jigs Software is used and operations are carried out on the PC. The procedure to enter each mode is the same for both cases. (*1)

3-1 Utility
Only the screens, which have been changed from those of the CF2001, are explained. No changes have been made to the functions which are not described.

Deletion

Deletion

Deletion

X-Rite Calibration (*1)

Deletion

(*2)

3-2 Tech. Rep. Mode
Only the screens, which have been changed from those of the CF2001, are explained below. No changes have been made to the functions which are not described. The biggest difference is that the adjustment of IR has been eliminated.

Basic Screen

SMART

(*2)
Deletion

(*1) System Input

Machine Adjust

Deletion

4) Field Service
4-1 Adjustments

4-2 Service Jigs and Tools

4-3 F/W Updating
NOTE: When turning OFF the printer, be sure to shut down the controller from the control panel and then turn OFF the Power Switch of the printer.

4-1 Adjustments
Adjustment Item Top Margin Left Margin Dup. Left Margin Paper Loop Color Shift Correction Fuser Nip Fuser Speed Fuser Temp. PRT Max Density PRT Highlight Background Voltage Margin X-Rite Calibration All adjustments are to be made using the Service Jigs Software from the PC. Specific details of the various adjustments are the same as those of the CF2001. Remark

Refer to Gradation Adjustment of the Set-up Instructions.

4-2 Service Jigs and Tools
Jigs and Tools Shipped with the Printer

IU Lower Cover

IU Handle

Cleaning Jig

Cleaning Pad

Jigs and Tools which are exclusively replacement parts
Memory Card

Jigs and Tools required for adjustments and setting
Refer to the Adjustment Service Jigs List.

4-3 F/W Updating
Changes: Due to the lack of a control panel, updating of F/W is verified using LED's 3 and 4 on PWB-H. This requires that the Rear Cover and PWB Cover be removed. Updating Procedure:
1. After the Memory Card has been inserted, plug in the power cord and turn ON the Power Switch. 2. LED's 3 and 4 on PWB-H blink alternately. (*1) ' 3. In approximately 12 to 13 minutes, LED's 3 and 4 light up steadily, indicating that the updating ' is completed. (*2) 4. Unplug the power cord and remove the Memory Card.

PWB-H

LED3

LED4

Memory Card

5) System Control Block Diagram
RS 232C Switchbox 422 to RS 232C Level Converter Connected entrance of IR

Controller I/F Printer Panel Controller (Fiery X3e)

Service Jigs Software

MSC Board (PWB-H)

X-Rite DTP32/41

Option FN-107/108 JS-1002 AD-14 PF-117

PIC Board (PWB-PIC) LED Board (PWB-L) Master Board (PWB-I) LPH (Y,M,C,K)

Control system line Image bus line

End