Text preview for : DSC-P8 ADJ.pdf part of SONY DSC-P8 S.M.



Back to : SONY DSC-P8.part1.rar | Home

DSC-P8
Ver 1.0 2003. 03
Revision History

SECTION 6 ADJUSTMENTS

ADJ

Link
Before starting adjustments
Adjusting items when replacing main parts and boards

SERVICE MODE
APPLICATION FOR ADJUSTMENT (SEUS) DATA PROCESS

CAMERA SECTION ADJUSTMENTS
SERVICE MODE
PREPARATIONS BEFORE ADJUSTMENTS INITIALIZATION OF 0E, 2F, 4F, 6F PAGE DATA VIDEO SYSTEM ADJUSTMENTS CAMERA SYSTEM ADJUSTMENTS LCD SYSTEM ADJUSTMENTS

Contents of LEVEL 2 and LEVEL 3 Service Manual
CONTENTS 1. SERVICE NOTE 2. DISASSEMBLY 3. BLOCK DIAGRAMS 4. PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS 5. REPAIR PARTS LIST LEVEL 2 a a OVERALL POWER CD-432, SW-386, ST-81 MS-130 BOARD EXPLODED VIEWS ELECTRICAL PARTS LEVEL 3 SY-83, JK-243, JK-244 BOARD a (JK-244, SY-83 BOARD)

9-876-226-51

Sony EMCS Co.

2003C0500-1 ©2003.3 Published by DI Customer Center

DSC-P8
TABLE OF CONTENTS
Section Title Page Section
8.

Title

Page

6.

ADJUSTMENTS

Self Diagnosis Code ······················································ 6-34

Before Starting Adjustment ······················································· 6-1 1-1. Adjusting Items when Replacing Main Parts and Boards ···················································· 6-2 6-1. Camera Section Adjustments ··········································· 6-3 1-1. Preparations Before Adjustments ···································· 6-3 1-1-1. List of Service Tools ························································ 6-3 1-1-2. Preparations ····································································· 6-4 1-1-3. Discharging of the Flashlight Power Supply ··················· 6-5 1-1-4. Precautions ······································································ 6-6 1. Setting the Switch ···························································· 6-6 2. Order of Adjustments ······················································ 6-6 3. Subjects ··········································································· 6-6 4. Preparing the Flash Adjustment Box ······························· 6-7 1-2. Initialization of 0E, 2F, 4F, 6F Page Data ······················· 6-8 1-2-1. Initialization of 0E, 2F, 4F, 6F Page Data ······················· 6-8 1. Initializing 0E, 2F, 4F, 6F Page Data ······························· 6-8 2. 0E Page Table ·································································· 6-8 3. 2F Page Table ·································································· 6-8 4. 4F Page Table ·································································· 6-8 5. 6F Page Table ·································································· 6-9 1-3. Video System Adjustments ············································ 6-12 1. Composite Video Level Adjustment ······························ 6-12 1-4. Camera System Adjustments ········································· 6-13 Data Setting During Camera System Adjustments ········ 6-13 Picture Frame Setting ···················································· 6-14 1. Flange Back Adjustment (Using the minipattern box) ·········································· 6-15 2. Flange Back Check ························································ 6-16 3. F No. Compensation ······················································ 6-16 4. Mechanical Shutter Adjustment ···································· 6-17 5. Light Value Adjustment ················································· 6-17 6. Mixed Color Cancel Adjustment ··································· 6-18 7. AWB 3200K Standard Data Input ································· 6-18 8. AWB 5800K Standard Data Input ································· 6-19 9. AWB 5800K Check ······················································· 6-19 10. AWB 3200K Check ······················································· 6-20 11. CCD Linearity Check ···················································· 6-20 12. Color Reproduction Adjustment ···································· 6-23 13. CCD White Defect Compensation ································ 6-24 14. CCD Black Defect Compensation ································· 6-24 15. Strobe Adjustment ························································· 6-25 16. AF Illumination Check ·················································· 6-26 1-5. LCD System Adjustments ············································· 6-27 1. LCD Initial Data Input ·················································· 6-27 2. VCO Adjustment (SW-386 Board) ································ 6-28 3. Bright Adjustment (SW-386 Board) ······························ 6-28 4. Contrast Adjustment (SW-386 Board) ·························· 6-29 5. Black Limit Adjustment (SW-386 Board) ····················· 6-29 6. V-COM Adjustment (SW-386 Board) ··························· 6-30 7. White Balance Adjustment (SW-386 Board) ················ 6-30 6-2. Service Mode ································································· 6-31 2-1. Application for Adjustment (SEUS) ······························ 6-31 2-1-1. Using Method of SEUS ················································· 6-31 1. Connection ····································································· 6-31 2. Operation ······································································· 6-31 2-1-2. Precaution on Use of SEUS ··········································· 6-31 2-2. Data Process ·································································· 6-32 2-3. Service Mode ································································· 6-32 1. Setting the Test Mode ···················································· 6-32 2. Bit Value Discrimination ··············································· 6-33 3. Mode Dial Check ··························································· 6-33 4. Switch Check (1) ··························································· 6-33 5. Switch Check (2) ··························································· 6-34 6. LED Check ···································································· 6-34 7. LCD & Back Light Bright Check ·································· 6-34

* The color reproduction frame is shown on page 6-35.

--2--

DSC-P8

COVER
Before starting adjustment

SECTION 6 ADJUSTMENTS

EVR Data Re-writing Procedure When Replacing Board
The data that is stored in the repair board, is not necessarily correct. Perform either procedure 1 or procedure 2 or procedure 3 when replacing board.

Procedure 1
Save the EVR data of the machine in which a board is going to be replaced. Download the saved data after a board is replaced.
(Machine before starting repair) PC PC (Machine after a board is replaced)

Save the EVR data to a personal computer.

Download the saved data to a machine.

Procedure 2
Remove the EEPROM from the board of the machine that is going to be repaired. Install the removed EEPROM to the replaced board.
Remove the EEPROM and install it.

(Former board)

(New board)

Procedure 3
When the data cannot be saved due to defective EEPROM, or when the EEPROM cannot be removed or installed, save the data from the same model of the same destination, and download it.
(Machine to be repaired) PC (Machine to be repaired)

Download the data. Save the data.

(The same model of the same destination)

After the EVR data is saved and downloaded, check the respective items of the EVR data. (Refer to page 6-2 for the items to be checked.)

6-1

DSC-P8

COVER
1-1. Adjusting items when replacing main parts and boards
When replacing main parts and boards, adjust the items indicated by z in the following table.
Replaced parts Block replacement Mounted parts replacement
(CAMERA DSP, 128M SDRAM)

Board
replacement

(LCD drive, Timing generator)

(Camera Module)

(Back light unit)

(VIDEO AMP)

(CCD imager)

(LCD panel)

Adjustment section

Adjustment
IC152 (CH-122 board)

IC601 (HM (3M SA) board)

(COMPLETE) (Note) SY-83 board

(COMPLETE)

Lens block assy (Note)

(COMPLETE) SW-386 board

LCD901

IC001

IC503

IC101

IC101

SW-386 board

CD-432 board

SY-83 board

SY-83 board

SY-83 board

SY-83 board

Initialization of 0E, 2F, 4F, Initialization of 0E, 2F, 4F, 6F page data 6F page data Video Camera Composite video level adj. Flange back adj. F No. compensation Mechanical shutter adj. Light value adj. Mixed color cancel adj. AWB 3200K standard data input AWB 5800K standard data input CCD linearity check Color reproduction adj. CCD (white and black) defect compensation Strobe adj. LCD LCD initial data input VCO adj. Bright adj. Contrast adj. Black limit adj. V-COM adj. White balance adj. z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z

z z z z z z z z z

z z z z z

z z z z z z z z z z z z z z z z z z z z z

Table 6-1-1
Note : When replacing the lens block or the SY-83 board, refer to "Precaution on Replacing the Video Lens or the SY-83 board" of Flange Back Adjustment. (See page 6-16)

6-2

SY-83 board

ST-81 board

LCD block

LCD block

Flash unit

IC504

D901

(EEPROM)

(EVR)

z z z z z z z z z

z z z

DSC-P8

COVER
6-1. CAMERA SECTION ADJUSTMENTS
1-1. PREPARATIONS BEFORE ADJUSTMENTS
1-1-1. List of Service Tools · Oscilloscope · Color monitor · Vectorscope · Regulated power supply · Digital voltmeter · Calculating machine capable of calculating hexadecimal numbers. Ref. No. Name Parts Code
J-1 J-2 J-3 J-4 J-5 J-6 J-7 J-8 J-9 J-10 Filter for color temperature correction (C14) Pattern box PTB-450 Color bar chart for pattern box Siemens star chart Clear chart for pattern box Personal computer USB cable HASP key and application for adjustment (SEUS) Minipattern box Back ground paper

Usage

Auto white balance adjustment/check J-6080-058-A White balance adjustment/check J-6082-200-A J-6020-250-A J-6080-875-A For checking the flange back J-6080-621-A OS: Windows 98/98SE/Me/2000/XP Home/XP Pro USB connector × 2 1-823-932-11 For connecting the camera to PC Contact our service headquater of each area how to get the application for adjustment (SEUS) and HASP key J-6082-353-B For adjusting the flange back J-2501-130-A For adjusting the strobe

J-1

J-2

J-3

J-4

J-5

J-6

J-7

J-8

J-9

J-10

and application for adjustment (SEUS)

Fig. 6-1-1

6-3

DSC-P8

1-1-2. Preparations 1) Connect the equipment for adjustments according to Fig. 6-1-3. 2) Start up the application for adjustment (SEUS). Note 1: Setting the "Forced CAMERA mode power ON Mode" 1) Select page: 00, address: 01, and set data: 01. 2) Select page: 2F, address: 21, and write data 03. The above procedure will enable the camera power to be turned on. After completing adjustments, be sure to exit the "Forced CAMERA mode power ON Mode". Note 2: Exiting the "Forced CAMERA mode power ON Mode" 1) Select page: 00, address: 01, and set data: 01. 2) Select page: 2F, address: 21, and write data: 00. 3) Select page: 00, address: 01, and set data: 00.

Pattern box

L

Front of the lens

L = About 25 cm

Fig. 6-1-2

DSC-P8

Insert the Memory Stick and the Batteries*.

AC power adaptor AC IN To DC IN jack To A/V OUT jack Vectorscope Color monitor Terminated 75 Video (yellow)

To USB connector

PC with USB connectors (x 2) (Windows 98/98SE/ME/2000/XP)

Audio (Black) To USB connector USB cable (1-823-932-11)

HASP Key
To USB connector

Fig. 6-1-3

6-4

LOCK

DSC-P8

1-1-3. Discharging of the Flashlight Power Supply The capacitor which is used as power supply of flashlight is charged with 200 V to 300 V voltage. Discharge this voltage before starting adjustments in order to protect service engineers from electric shock during adjustment. Discharge procedure 1. Press the FLASH button (SW-386 board S004 (CONTROL UP)) and set the NO FLASH mode. 2. Fabricate the discharging jig as shown in Fig. 6-1-5 locally by yourself. Connect the discharging jig to the positive (+) and negative (­) terminal of the flash voltage charge capacitor. Allow ten seconds to discharge the voltage.

Capacitor

R:1 k/1 W (Part code: 1-215-869-11)

ST -81

Fig. 6-1-4

1 k/1 W

Wrap insulating tape.

Fig. 6-1-5

6-5

DSC-P8

1-1-4. Precautions 1. Setting the Switch Unless otherwise specified, set the switches as follows and perform adjustments. 1. Mode Dial .......................................... CAMERA 2. ZOOM switch (SW-386 board S001, S002) .............. WIDE end 3. EV (Menu display) ............................ 0EV 4. DISPLAY/LCD ON/OFF button (SW-386 board S005) ........................ OSD OFF 5. WB (WHITE BALANCE) (Menu display) ................................... AUTO 6. P.EFFECT (Menu display) ................ OFF 7. VIDEO OUT (SET UP setting) ......... NTSC 2. Order of Adjustments Basically carry out adjustments in the order given. Color bar chart (Color reproduction adjustment frame)
Yellow Cyan Green White Magenta Red
H Electronic beam scanning frame

C

C=D

D

Blue

Yellow Cyan Green White Magenta Red Blue

CRT picture frame

B A A=B/2

B A Enlargement

V Fig. b (monitor TV picture)

Fig. a (VIDEO terminal of A/V jack output waveform) Difference in level

Adjust the camera zoom and direction to obtain the output waveform shown in Fig a and the monitor TV display shown in Fig. b.

B

A

Fig. 6-1-6
3. Subjects 1) Color bar chart (Standard picture frame). When performing adjustments using the color bar chart, adjust the picture frame as shown in Fig. 6-1-6. (Standard picture frame) 2) Clear chart (Standard picture frame) Remove the color bar chart from the pattern box and insert a clear chart in its place. (Do not perform zoom operations during this time)

6-6

DSC-P8

4. Preparing the Flash Adjustment Box A dark room is required to provide an accurate flash adjustment. If it is not available, prepare the flash adjustment box as given below; 1) Provide woody board A, B and C of 15 mm thickness.
woody board A (2) 400 mm woody board B (2) 370 mm woody board C (1) 700 mm

513 mm

513 mm

700 mm

730 mm

700 mm

Fig. 6-1-7

2) Apply black mat paint to one side of woody board A and B. 3) Attach background paper (J-2501-130-A) to woody board C. 4) Assemble so that the black sides and the background paper side of woody board A, B and C are internal. (Fig. 6-1-8)
woody board A

woody board B

woody board A

woody board B woody board C

Fig. 6-1-8

6-7

DSC-P8

COVER
1-2. INITIALIZATION OF 0E, 2F, 4F, 6F PAGE DATA
2. 0E Page table Note 1: Fixed data-1: Initialized data. (Refer to step 4 of " 1. Initializing of 0E, 2F, 4F, 6F Page Data") Note 2: Fixed data-2: Modified data. (Refer to step 6 of " 1. Initializing of 0E, 2F, 4F, 6F Page Data") Address Initial value 00 to FF Remark Fixed data-1 (Initialized data)

1-2-1. Initialization of 0E, 2F, 4F, 6F Page Data 1. Initializing of 0E, 2F, 4F, 6F Page Data Note 1: Initialize the data every page of 0E, 2F, 4F, and 6F. Note 2: If the 4F page data has been initialized, the following adjustments need to be performed again. 1) Video system adjustment 2) LCD system adjustments Note 3: If the 6F page data has been initialized, the following adjustments need to be performed again. 1) Camera system adjustments Adjusting Page Adjusting Address Adjusting Page Adjusting Address Adjusting Page Adjusting Address Adjusting Page Adjusting Address 0E 00 to FF 2F 00 to 7F 4F 00 to FF 6F 00 to FF

3. 2F Page table Note 1: Fixed data-1: Initialized data. (Refer to step 5 of " 1. Initializing of 0E, 2F, 4F, 6F Page Data") Note 2: Fixed data-2: Modified data. (Refer to step 6 of " 1. Initializing of 0E, 2F, 4F, 6F Page Data") Address Initial value 00 to 20 21 22 to 7F 00 Test mode Fixed data-1 (Initialized data) Remark Fixed data-1 (Initialized data)

Initializing Method: 1) Click [Page Edit] on the SEUS screen to display the SEUS PAGE EDIT screen. 2) Click [Page], and then enter the page to be initialized. 3) Click [Preset Data Read] to display the Set ID input screen. 4) For page 0E, enter Set ID = "00" and read the initializing data on the SEUS PAGE EDIT screen. 5) For page 2F, 4F and 6F, enter Set ID = "08" and read the initializing data on the SEUS PAGE EDIT screen. 6) On the SEUS PAGE EDIT screen, change the data at "Fixed data-2" address given in the table on the page to be initialized. Note: New data for change are not listed in the table. If the data are to be changed, read and copy the data from the same model. Copying the data from different models may cause an operation failure. 7) Confirm that the data at respective adjustment addresses are the initial values (adjustment initial values) given in the table. If different, change to the adjustment initial values. 8) Click [Write] to write the initializing data to the set. 9) Click [Close] to close the SEUS PAGE EDIT screen. Processing after Completing Initializing Order Page Address 1 2 3 2F 20 20 21 00 01 Data 04 [Write] 29 [set] 29 [Write] (Note) Procedure

4. 4F Page table Note 1: Fixed data-1: Initialized data. (Refer to step 5 of " 1. Initializing of 0E, 2F, 4F, 6F Page Data") Note 2: Fixed data-2: Modified data. (Refer to step 6 of " 1. Initializing of 0E, 2F, 4F, 6F Page Data") Address Initial value 00 to 81 82 83 84 85 86 87 88 89 8A 8B to 9F A0 A1 to A7 A8 A9 AA to FF 80 8C 6C 42 90 9A 91 AF 2D Remark Fixed data-1 (Initialized data) VCO adj. (NTSC mode) VCO adj. (PAL mode) V-COM adj. Bright adj. Black limit adj. Fixed data-1 (Initialized data) White balance adj. Contrast adj. Fixed data-1 (Initialized data) Video sync level adj. Fixed data-1 (Initialized data) Fixed data-2 Fixed data-2 Fixed data-1 (Initialized data)

Note: At this time, the set is reset and the power is turns off once and then on again. Accordingly, the message "Receive Packet Error" is displayed on the SEUS screen, and the SEUS goes in "disconnect" state, but this is not a trouble. Click [Connect] on the SEUS screen to restore the "connected" state.

6-8

DSC-P8

5. 6F Page Table Note 1: Fixed data-1: Initialized data. (Refer to step 5 of " 1. Initializing of 0E, 2F, 4F, 6F Page Data") Note 2: Fixed data-2: Modified data. (Refer to step 6 of " 1. Initializing of 0E, 2F, 4F, 6F Page Data") Address Initial value 00 to 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 FF FF FF FF 00 90 FF FF 34 F5 87 71 10 C0 00 00 00 00 00 00 20 20 26 46 0A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Flange back adj. AF Ilumination check. Remark Fixed data-1 (Initialized data)

Address Initial value 3A 3B 3C 3D 3E 3F 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 to 5F 60 61 62 63 64 65 66 67 68 to 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 FF 00 00 00 00 40 90 17 DF 3E A8 19 00 00 00 00 00 30 FE 6D 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 FF

Remark

Flange back adj.

Fixed data-1 (Initialized data)

Flange back adj.

Fixed data-1 (Initialized data)

F No. compensation

Light value adj. Fixed data-1 (Initialized data) F No. compensation Mechanical shutter adj. Mixed color calcel adj.

AWB 3200K standard data input

6-9

DSC-P8

Address Initial value 77 78 79 7A 7B 7C 7D 7E 7F 80 81 82 83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9E 9F A0 A1 A2 A3 A4 A5 A6 36 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 28 9B 24 39 27 1F 25 8A 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 2B 00 60 00 FE F9 88

Remark

Address Initial value A7 A8 A9 AA AB AC AD AE B0 0D 04 9E 97 86 AF F9 F8 00 00 00 00 00 26 74 10 37 10 37 00 00 00 00 00 00 00 00 00 00 00 28 1B 00 00 00 80 88 98 90 88 00 00 00 00 00 00

Remark

Color reproduction adj.

AWB 3200K standard data input

AF B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4

AWB 3200K standard data input AWB 5800K standard data input AWB 3200K standard data input AWB 5800K standard data input AWB 3200K standard data input Fixed data-1 (Initialized data) Strobe balance adj.

AWB 5800K standard data input

Mechanical shutter adj.

Color reproduction adj.

D5 D6

6-10

DSC-P8

Address Initial value D7 D8 D9 DA DB DC DD DE DF E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF F0 to FF 14 FF FF FF 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

Remark Mechanical shutter adj.

Strobe balance adj.

Fixed data-1 (Initialized data)

6-11

DSC-P8

COVER
1-3. VIDEO SYSTEM ADJUSTMENTS
1. Composite Video Level Adjustment Adjust the sync level of the composite video signal output and check the burst level of the composite video signal output. Mode Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified Value PLAY Arbitrary Video terminal of A/V OUT jack (75 terminated) Oscilloscope 4F A0 Sync level: A = 286 ± 5 mV (NTSC mode) A = 300 ± 5 mV (PAL mode) Burst level: B = 286 ± 30 mV (NTSC mode) B = 300 ± 30 mV (PAL mode)

Note: Check that the data of page: 60, address: C1 is "01". If not, turn the power of unit OFF/ON. Adjusting method: Order Page Address 1 2 3 4 5 6 00 4F 40 4F 4F 01 02 F1 A0 A0 Data 01 [Set] 03 [Set] 04 [Set] Change the data and set the sync level (A) to the specified value. Procedure

[Write]
Check the burst level (B) to the specified value.

Processing after Completing Adjustments: Order Page Address 1 2 3 4F 40 00 02 F1 01 Data 00 [Set] 00 [Set] 00 [Set] Procedure

B A

H

Fig. 6-1-9

6-12

DSC-P8

COVER
1-4. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the specified values of "VIDEO SYSTEM ADJUSTMENTS" are satisfied. Note: For "CAMERA SYSTEM ADJUSTMENTS", perform in order of item numbers. Data setting during camera system adjustments Perform the following data setting before the camera system adjustments. It is not necessary to perform the following data setting everytime when you perform some items of camera system adjustments continuously unless the power is turned off. Only when the power is turned off during this adjustments, perform the data setting again, then continue the adjustments. Set up setting: 1) VIDEO OUT of SET UP setting............... NTSC (NTSC mode) (This adjustment must be performed in NTSC mode, so don't set the SET UP setting to "PAL") After completing the camera system adjustments, release the data setting: 1) Click [Page Edit] on the SEUS screen to display the SEUS PAGE EDIT screen. 2) Click [Page], and then enter the page "0E". 3) Click [Preset Data Read] to display the Set ID input screen. 4) Enter Set ID = "00" and read the initializing data on the SEUS PAGE EDIT screen. 5) Check that all the data is "FF". 6) Click [Write] to write the initializing data to the set. 7) Click [Close] to close the SEUS PAGE EDIT screen. 8) Release the data setting which has been executed before adjustment. Order Page Address 1 2 3 4 5 Data setting method Order Page Address 1 2 3 4 5 6 7 8 9 10 11 12 13 14 00 6F 4F 7F 20 20 00 4F 2F 60 4F 60 60 01 00 01 68 00 01 01 0F 21 C1 02 6C 2C Data 01 [Set] 20 [Write] 20 [Write] 00 [Write] 29 [Set] 29 [Write] 01 [Set] 01 [Write] 03 [Write] Check the data changes to "02". (Note 1) Procedure 6 7 8 4F 7F 60 60 4F 2F 4F 00 01 68 2C 6C 02 21 0F 01 Data 00 [Write] 40 [Write] 00 [Set] 00 [Set] 00 [Set] 00 [Write] 00 [Write] 00 [Set] Procedure

[Read]
02 [Set] 01 [Set] 01 [Set]

Wait for 1 second.

Note 1: At this time, the set is reset and the power is turned off once and then on again. Accordingly, the message "Receive Packet Error" is displayed on the SEUS screen, and the SEUS goes in "disconnect" state, but this is not a trouble. Click [Connect] on the SEUS screen to restore the "connected" state. (In case that the power does not turn on again, press the power button.) Note 2: Repeat the "Data setting method", if the power was turned off and on during the "CAMERA SYSTEM ADJUSTMENTS".

6-13

DSC-P8

Picture Frame Setting Mode Subject CAMERA Color bar chart (Standard picture frame with the zoom lens at WIDE end) Video terminal of A/V OUT jack (75 terminated) Oscilloscope and monitor TV A=B/2, C/2=D, E=F

How to reset the zoom and focus when they deviated: Order Page Address 1 2 3 4 5 6 7 60 60 60 60 60 60 60 90 91 92 93 01 07 01 Data 00 [Set] 00 [Set] YL [Set] YH [Set] 79 [Write] (Note 2) (Note 2) Check the data changes to "01". Procedure

Measurement Point Measuring Instrument Specified value

[Read]
00 [Write]

Switch setting: 1) FOCUS (Menu setting) ................. Multi AF 2) MACRO (Control button) ............. ON Setting method: Order Page Address 1 2 60 8C 30 [Set] Enter the output of VIDEO OUT to the monitor TV, and move the position as shown in Fig. 6-1-12. Horizontal width of black (A, D) on the color bar chart should be a half of that of one color bar (B, C). (See Fig. 6-1-10) With vertical width of black (E, F) set in same, the color bar chart should come to the center of monitor TV. (See Fig. 6-1-11) Check that the color bar on the monitor TV is focused. 10 44 Data Procedure Shoot the color bar chart with the zoom WIDE end.

Note 2: The data noted down at step 6 and 7 of "Setting method". Check on the oscilloscope 1. Horizontal period
A=B/2 B A C/2=D C D

3

4

5

Fig. 6-1-10
2. Vertical period
E E=F F

6

7

[Read]

Read the data. Note down the data, and this is named YH data. Read the data. Note down the data, and this is named YL data.
V

8

10

45

[Read]

Fig. 6-1-11
Check on the monitor TV

Processing after Completing Adjustments: Order Page Address 1 60 8C Data 00 [Set] Procedure

Color bar chart picture frame

Monitor TV picture frame

Fig. 6-1-12

6-14

DSC-P8

1.

Flange Back Adjustment (Using the minipattern box) The flange back of inner focus lens is adjusted automatically. If shifted, the auto focus is disordered. Mode Subject Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value 1 Specified value 2 6F 18 to 3E, 40 to 53 00 0A to 40 CAMER Siemens star chart with ND filter for minipattern box (Note 1) Check operation on monitor TV

Adjusting method: Order Page Address 1 13 [Write] 27 [Write] (Note 5) Check the data changes to "01". Check that the data satisfied the specified value 1. Check that the data satisfied the specified value 2. Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) 60 60 60 6F 01 01 02 3E

2 3 4 5

[Read] [Read]

Note 1: Dark Siemens star chart. Note 2: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Caution: If the video lens or SY-83 board was replaced, make a setting by referring to "Precaution on Replacing the Video Lens or the SY-83 Board" and then perform the adjustment. Preparations before adjustments: 1) The minipattern box is installed as shown in the following figure. Note 3: The attachment lenses are not used. Note 4: Take care not to hit the mini-pattern box when extending the lens. 2) Install the minipattern box so that the distance between it and the front of lens of camera is less than 3 cm. 3) Make the height of minipattern box and the camera equal. 4) Check the output voltage of the regulated power supply is the specified voltage ± 0.01 Vdc. 5) Check that the center of Siemens star chart meets the center of shot image screen with the zoom lens at TELE end and WIDE end respectively. Specified voltage: The specified voltage varies according to the minipattern box, so adjustment the power supply output voltage to the specified voltage written on the sheet which is supplied with the minipattern box.
Below 3 cm Minipattern box Camera Camera table Regulated power supply Output voltage : Specified voltage ± 0.01 Vdc Output current : more than 3.5 A

6 7 8 9

6F 60 60

24 01 01

[Read]
00 [Write] 25 [Write]

Wait for 3 seconds.

Note 5: The adjustment data will be automatically input to page: 6F, address: 18 to 3E and 40 to 53. Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Perform "Flange Back Check ". Procedure

[Precaution on Replacing the Video Lens or the SY-83 Board] The DSC-P8 uses the position sensor to detect the zoom position. Accordingly, the zoom position will vary if the position data changes due to the replacement of the video lens or the SY-83 board, thus causing the video lens to collide against the mechanism end when the power is turned off. Though the position data is calibrated at the "Flange Back Adjustment", add the following work when making an adjustment at the replacement of video lens to prevent a collision of video lens. When Replacing the Video Lens 1) With current video lens assembled, turn the power on, and set the data of page: 6F, address: 3E to "FF", then turn the power off. 2) Replace the video lens with a new one, turn the power on, and perform the "Flange Back Adjustment". Thus, new position data will be written. When Replacing the SY-83 Board 1) Replace the SY-83 board with a new one, set the mode dial to "PLAY", turn the power on, and set the data of page: 6F, address:3E to "FF", then turn the power off. 2) Set the mode dial to "CAMERA", turn the power on, and perform the "Flange Back Adjustment". Thus, new position data will be written.

Red (+) Black (­) Yellow (SENS +) White (SENS ­) Black (GND) Need not connected

Fig. 6-1-13

6-15

DSC-P8

2.

Flange Back Check CAMERA Siemens star (1.0 m from the front of the lens) (Luminance: 200 to 400 lux) Check operation on monitor TV

Mode Subject

3. F No. Compensation Compensate the unevenness of the iris meter sensitivity. Mode Subject CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) Data of page: 6F, address: 6B 6F 60 to 64, 6B to 6D 00

Measurement Point Measuring Instrument Specified value

Measurement Point Focused at the TELE end and WIDE end Adjustment Page Adjustment Address Specified value Data Procedure "Flange Back Adjustment" is completed. Place the Siemens star 1.0 from the front of the lens. To open the IRIS, decrease the luminous intensity to the Siemens star up to a point before noise appear on the image.

Checking method: Order Page Address 1 2

Note 1: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Adjusting methd: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 60 60 6F 01 02 6B BB [Write] (Note 2) Check the data changes to "01". Check that the data satisfied the specified value.

3

2 3 4 5

4 5 6

60 5F 7B

8C 3D 98

30 [Set] 50 [Set] 94 [Set] Set the zoom lens to the TELE end then set the center of the Siemens star chart in the center of the TV monitor. Check that the lens is focused. (Note 1)

[Read] [Read]

7

Note 2: The adjustment data will be automatically input to page: 6F, address: 60 to 64 and 6B to 6D. Processing after Completing Adjustments: Order Page Address 1 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

8 9 60 2C 01 [Set]

10

While observe the TV monitor, change the zoom to the WIDE end and check that the lens is focused.

2

Note 1: How to find the data Decrease the data of page: 5F, address: 3D until four sides of a black frame can be seen on the monitor, then find the value. The largest value under this condition will be the seting value. If the value is less than 50, change monitorrs. Processing after Completing Adjustments: Order Page Address 1 2 3 4 5F 60 7B 3D 8C 98 Data Procedure

[Read] 00 [Set] [Read]
Release "Data setting during camera system adjustment" (Refer to page 6-13)

6-16

DSC-P8

4. Mechanical Shutter Adjustment Adjust the period which the mechanical shutter is closed, and compensate the exposure. Mode Subject CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) Data of page: 6F, address: 6B 6F 6B to 6D, B8 to D7 00

5. Light Value Adjustment Adjust the standar light value. Mode Subject CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) Data of page: 10, address: 0C and 0D (2byte data) (Note 2) Data of page: 6F, address: 65 Adjustment Page Adjustment Address Specified value 1 Specified value 2 6F 65 to 67 0FE0 to 1020 30 to 44

Measurement Point

Measurement Point Adjustment Page Adjustment Address Specified value

Note 1: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Adjusting method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 60 60 6F 01 02 6B AD [Write] (Note 2) Check the data changes to "01". Check that the data satisfied the specified value.

Note 1: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Note 2: 2byte data is upper 1byte data and lower 1 byte data. XX XX Lower 1byte data (Page: 10, adderss: 0D) Upper 1byte data (Page: 10, adderss: 0C) Adjusting method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 60 60 10 10 01 02 0C 0D 0D [Write] (Note 3) Check the data changes to "01". Read the data (Upper 1byte). Read the data (Lower 1byte). Check that the 2byte data (Note 2) satisfied the specified value 1. 6F 65

2 3 4 5

[Read] [Read]

2 3 4 5 6

Note 2: The adjustment data will be automatically input to page: 6F, address: 6B to 6D and 8B to D7. Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

[Read] [Read] [Read]

7

8

[Read]

Check that the data satisfied the specified value 2.

Note 3: The adjustment data will be automatically input to page: 6F, address: 65 to 67. Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

6-17

DSC-P8

6. Mixed Color Cancel Adjustment Correct the dispersion of Gr/Gb filter on CCD imager Mode Subject CAMERA Color bar chart (Standard picture frame with the zoom lens at WIDE end) 6F 6E and 6F 00

7. AWB 3200K Standard Data Input Adjust the white balance reference at 3200K. Mode Subject CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) 6F 70 to 87, B0, B2, and B4 00

Adjustment Page Adjustment Address Specified value

Adjustment Page Adjustment Address Specified value

Note 1: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Adjusting method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 6F 60 60 60 6F B5 01 01 02 B5 FF [Write] D7 [Write] Wait for 3 seconds. D5 [Write] (Note 2) Check the data changes to "01". Check that the data satisfied the specified value.

Note 1: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Adjusting method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 6F 60 60 6F B5 01 02 B5 FF [Write] 0B [Write] (Note 2) Check the data changes to "01". Check that the data satisfied the specified value.

2 3 4 5 6 7 8

2 3 4 5 6

[Read] [Read]

[Read] [Read]

Note 2: The adjustment data will be automatically input to page: 6F, address: 70 to 87, B0, B2 and B4. Processing after Completing Adjustments: Order Page Address Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

Note 2: The adjustment data will be automatically input to page: 6F, address: 6E and 6F Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

1 2

60

01

6-18

DSC-P8

8. AWB 5800K Standard Data Input Adjust the white balance reference at 5800K. Mode Subject CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) Filter C14 for color temperature correction 6F 88 to A3, B1, and B3 00

9.

AWB 5800K Check CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) Filter C14 for color temperature correction Data of page: 6F, address: B5 00

Mode Subject

Filter Measurement Point Specified value

Filter Adjustment Page Adjustment Address Specified value

Note: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Checking method: Order Page Address 1 Data Procedure Place the C14 filter on the lens. Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 6F 60 60 6F B5 01 02 B5 FF [Write] 3F [Write] Check the data changes to "01". Check that the data satisfied the specified value.

Note 1: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Note 2: Perform this check after "AWB 3200K Standard Data Input" without a break. Adjusting method: Order Page Address 1 Data Procedure Place the C14 filter on the lens. Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 6F 6F 6F 6F 6F 60 60 6F A0 A1 A2 A3 B5 01 02 B5 2B [Write] 00 [Write] 60 [Write] 00 [Write] FF [Write] A5 [Write] (Note 3) Check the data changes to "01". Check that the data satisfied the specified value.

2

2

3 4 5 6 7

3 4 5 6 7 8 9 10 11

[Read] [Read]

Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

[Read] [Read]

Note 3: The adjustment data will be automatically input to page: 6F, address: 88 to A3, B1 and B3. Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

6-19

DSC-P8

10. AWB 3200K Check Mode Subject CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) Data of page: 6F, address: B5 00

11. CCD Linearity Check Check that CCD output keep being staraight even ISO sensitivity is changed. Mode Subject CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) 97 to 103 (Decimal) 96 to 104 (Decimal)

Measurement Point Specified value

Note: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Checking method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 6F 60 60 6F B5 01 02 B5 FF [Write] 0F [Write] Check the data changes to "01". Check that the data satisfied the specified value. (Note 2)

Specified value 1 Specified value 2

Note: 2byte data is upper 1byte data and lower 1byte data. XX XX Lower 1byte data (Page: 10, address: 81 or 83) Upper 1byte data (Page: 10, address: 80 or 82) Checking method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 75 60 77 77 60 60 60 60 60 60 60 60 09 1F F7 F2 12 14 05 3C 3D 3E 3F 01 04 [Set] 80 [Set] 40 [Set] 00 [Set] 9F [Set] 90 [Set] 16 [Set] 28 [Set] 54 [Set] 14 [Set] 2A [Set] Wait for 2 seconds. F9 [Write] Wait for 1 second. 10 80 Read the data (Upper 1byte). Note down the data, and this is named D02. Read the data (Lower 1byte). Note down the data, and this is named D03. This 2byte data (Note) is named D1. 6D 6D 6D 6D 02 03 0A 0B D02 [Write] D03 [Write] D02 [Write] D03 [Write] Write the data noted down at order No. 17. Write the data noted down at order No. 18. Write the data noted down at order No. 17. Write the data noted down at order No. 18.

2 3 4 5 6

[Read] [Read]

2 3 4 5 6

Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

7 8 9 10 11 12 13 14 15 16 17

[Read]

18

10

81

[Read]

19 20 21 22 23

6-20

DSC-P8

Order Page Address 24 10 82

Data

Procedure Read the data (Upper 1byte). Note down the data, and this is named D06. Read the data (Lower 1byte). Note down the data, and this is named D07. This 2byte data (Note) is named D2.

Order Page Address 51 10 80

Data

Procedure Read the data (Upper 1byte). Note down the data, and this is named D08. Read the data (Lower 1byte). Note down the data, and this is named D09. This 2byte data (Note) is named D5.

[Read]

[Read]

25

10

83

[Read]

52

10

81

[Read]

26 27 28 29 30 31 32 33 34 35 36 10 80 60 01 F9 [Write] 6D 6D 6D 6D 60 77 06 07 0E 0F 01 72 D06 [Write] D07 [Write] D06 [Write] D07 [Write] 00 [Write] 48 [Set]

53 54 55 6D 6D 08 09 D08 [Write] D09 [Write]

Write the data noted down at order No. 24. Write the data noted down at order No. 25. Write the data noted down at order No. 24. Write the data noted down at order No. 25.

Write the data noted down at order No. 51. Write the data noted down at order No. 52. Read the data (Upper 1byte). Note down the data, and this is named D0C. Read the data (Lower 1byte). Note down the data, and this is named D0D. This 2byte data (Note) is named D6.

56

10

82

[Read]

57 Wait for 2 seconds. Wait for 1 second. 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75

10

83

[Read]

[Read]

Read the data (Upper 1byte). Note down the data, and this is named D00. Read the data (Lower 1byte). Note down the data, and this is named D01. This 2byte data (Note) is named D3.

6D 6D 60 60 60 60 60 60 60 60 60 75 77 77 77

0C 0D 01 12 14 1F 05 3C 3D 3E 3F 09 F7 F2 72

D0C [Write] D0D [Write] 00 [Write] 00 [Set] 00 [Set] 00 [Set] 00 [Set] 00 [Set] 00 [Set] 00 [Set] 00 [Set]

Write the data noted down at order No. 56. Write the data noted down at order No. 57.

37

10

81

[Read]

38 39 40 6D 6D 00 01

Write the data noted D00 [Write] down at order No. 36. Write the data noted D01 [Write] down at order No. 37.

41

10

82

[Read]

Read the data (Upper 1byte). Note down the data, and this is named D04. Read the data (Lower 1byte). Note down the data, and this is named D05. This 2byte data (Note) is named D4.

[Read] [Read] [Read] [Read]
Convert D3 to decimal notation, and obtain D3'. Convert D1 to decimal notation, and obtain D1'. Calculate S1 using following equations. (Decimal calculation) S1=(D3'÷D1') × 100 Check that the S1 satisfies the specified value 1.

42

10

83

[Read]

43 44 45 46 47 48 49 50 60 01 F9 [Write] 6D 6D 60 77 04 05 01 72 D04 [Write] D05 [Write] 00 [Write] 09 [Set]

Write the data noted down at order No. 41. Write the data noted down at order No. 42.

76

77 Wait for 2 seconds. Wait for 1 second.

6-21

DSC-P8

Order Page Address

Data

Procedure Convert S1 to hexadecimal notation. This Upper 1byte data is named S10. This Lower 1byte data is named S11.

Order Page Address 95 96

Data

Procedure Convert D6 to decimal notation, and obtain D6'. Convert D2 to decimal notation, and obtain D2'. Calculate S4 using following equations. (Decimal calculation) S4=(D6'÷D2') × 100 Check that the S4 satisfies the specified value 2. Convert S4 to hexadecimal notation. This Upper 1byte data is named S16. This Lower 1byte data is named S17.

78

79

6D

10

Write the Upper 1byte S10 [Write] data obtained at order No. 78. Write the Lower 1byte S11 [Write] data obtained at order No. 78. Convert D4 to decimal notation, and obtain D4'. Convert D2 to decimal notation, and obtain D2'. Calculate S2 using following equations. (Decimal calculation) S2=(D4'÷D2') × 100 Check that the S2 satisfies the specified value 1. Convert S2 to hexadecimal notation. This Upper 1byte data is named S12. This Lower 1byte data is named S13.

97

80 81 82

6D

11

98

99

83

100

6D

16

Write the Upper 1byte S16 [Write] data obtained at order No. 99. Write the Lower 1byte S17 [Write] data obtained at order No. 99.

84

101

6D

17

Processing after Completing Adjustments: Order Page Address 1 Data Procedure Release "Data settig during camera system adjustment" (Refer to page 6-13)

85

86

6D

12

Write the Upper 1byte S12 [Write] data obtained at order No. 85. Write the Lower 1byte S13 [Write] data obtained at order No. 85. Convert D5 to decimal notation, and obtain D5'. Convert D1 to decimal notation, and obtain D1'. Calculate S3 using following equations. (Decimal calculation) S3=(D5'÷D1') × 100 Check that the S3 satisfies the specified value 2. Convert S3 to hexadecimal notation. This Upper 1byte data is named S14. This Lower 1byte data is named S15.

87 88 89

6D

13

90

91

92

93

6D

14

Write the Upper 1byte S14 [Write] data obtained at order No. 92. Write the Lower 1byte S15 [Write] data obtained at order No. 92.

94

6D

15

6-22

DSC-P8

12. Color Reproduction Adjustment Adjust the color separation matrix coefficient so that proper color reproduction is produced. Mode Subject CAMERA Color bar chart (Standard picture frame with the zoom lens at WIDE end) Video terminal of A/V OUT jack (75 terminated) Data of page: 6F, address: B5 Measuring Instrument Adjustment Page Adjustment Address Specified value Vectorscope 6F A4 to AF 00

R-Y

R

MG

Measurement Point

YE

W B-Y B

Menu setting: 1) VIDEO OUT of SET UP menu ................................. NTSC (NTSC mode) Note 1: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Adjusting method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) Perfom "Picture frame setting" (Refer to page 6-14) 6F 60 60 60 6F B5 01 01 02 B5 FF [Write] AB [Write] Wait for 3 seconds. A9 [Write] (Note 2) Check the data changes to "01". Check that the data satisfied the specified value. Check the each color luminance point is in each color reproduction frame.
Burst position

G

CY

Fig. 6-1-14

2 3 4 5 6 7 8

[Read] [Read]

9

Note 2: The adjustment data will be automatically input to page: 6F, address: A4 to AF. Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

6-23

DSC-P8

13. CCD White Defect Compensation Mode Subject Measurement Point CAMERA Not required Data of page: 60, address: 55

14. CCD Black Defect Compensation Mode Subject CAMERA Clear chart (Standard picture frame with the zoom lens at WIDE end) Data of page: 60, address: 55

Note: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Adjusting method: Order Page Address 1 1E [Set] 0D [Set] 8B [Write] Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) 7D 7D 60 60 60 60 7D 7D 60 60 60 64 69 01 02 55 01 64 69 01 02 55

Measurement Point

Note 1: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Note 2: Check that there are no dust, no dirt and reflection of the clear chart. Note 3: Any subject other than the clear chart should be in the screen. Adjusting method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) 7D 60 60 60 60 60 60 60 60 60 65 90 91 92 93 01 30 07 01 02 4C [Set] 00 [Set] 03 [Set] 00 [Set] 00 [Set] 79 [Write] 08 [Set] Check the data changes to "01". Check the data changes to "01". Check the data. 00: Proceed to "Processing after Completing Adjustment" 00 to 0A : Normal 0B to FF : Defective

2 3 4 5 6 7 8 9 10 11 12

[Read] [Read]
00 [Write] 0F [Set] 60 [Set] 87 [Write]

Check the data changes to "01". Check the data. 00 to 7F: Normal 80 to FF: Defective 2 3 4 5 6 7 8 Check the data changes to "01". Check the data. 00 : Normal 01 to FF: Defective 9 10 11

[Read] [Read]

[Read]
8D [Write]

[Read]

Processing after Completing Adjustments: Order Page Address 1 2 3 4 60 7D 7D 01 64 69 Data 00 [Write] Procedure 12 60 55

[Read]

[Read] [Read]
Release "Data settig during camera system adjustment" (Refer to page 6-13)

13 14 15 16 17

60 7D 60 60 60

01 65 01 02 55

00 [Write] 5A [Set] 89 [Write] Check the data changes to "01". Check the data. 00 : Normal 01 to FF : Defective

[Read] [Read]

Processing after Completing Adjustments: Order Page Address 1 2 3 4 60 60 7D 01 30 65 Data 00 [Write] 00 [Set] Procedure

[Read]
Release "Data settig during camera system adjustment" (Refer to page 6-13)

6-24

DSC-P8

15. Strobe Adjustment Adjust the light value and white balance when strobe light flashed. Mode Subject Measurement Point Adjustment Page Adjustment Address Specified value 1 Specified value 2 CAMERA Flash adjustment box (Note 2) (50 cm from the front of lens) Data of page: 6F, address: DC and B5 6F B6, B7 and D8 to EF 05 to 0B 00

Adjusting method: Order Page Address 1 01 [Set] 00 [Set] 00 [Set] FF [Set] FF [Set] 01 [Set] 79 [Write] Check the data changes to "01". Check the flashing. (Note 5) Check the data changes to "01". Check the data is "00". Check the data changes to "02". Check the flashing. Check the data changes to "01". Check the data is "00". Check that the data satisfied the specified value 1. Check that the data satisfied the specified value 2. Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) 60 60 60 60 60 60 60 60 6F 60 60 6F 60 60 60 60 6F 6F 2C 90 91 92 93 6C 01 07 B5 01 02 D8 01 ED 01 02 D8 DC

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Note 1: Perform this adjustment in the Flash adjustment box. Note 2: Refer to "4. Preparing the Flash adjustment box". (See page 6-7). Note 3: "Strobe Adjustment" is available only once after the power is turned on. If the adjustment is retried, press the RESET swich using a thin and long pin. Note 4: Check that the data of page: 60, address: 02 is "00". If not, press the RESET switch using a thin and long pin. Switch setting: 1) FLASH (Control button) .................... ON

[Read]
FF [Write] B9 [Write]

[Read] [Read] 00 [Write] [Read]
E7 [Write]

[Read] [Read] [Read]

20

6F

B5

[Read]

Note 5: The adjustment data will be automatically input to page: 6F, address: B6, B7 and D8 to EF. Processing after Completing Adjustments: Order Page Address 1 2 3 4 5 6 7 8 60 60 60 60 60 60 60 01 90 91 92 93 2C 6C Data 00 [Write] 00 [Set] 00 [Set] 00 [Set] 00 [Set] 00 [Set] 00 [Set] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

6-25

DSC-P8

16. AF Illumination Check Check the deviation of optical axis of AF illuminator. Mode Subject Measurement Point Adjustment Page Adjustment Address Specified value CAMERA Flash adjustment box (Note 3) (50 cm from the front of lens) Displayed data of page: 6F, address: 10 6F 10 to 17 00

Note 1: Perform checking by making the shooting surface of the Flash adjustment box perpendicular to the optical axis of the camera. Note 2: Perform this checking in the Flash adjustment box. Restrict external light to enter the Flash adjustment box as less as possible. Note 3: Refer to "4. Preparing the Flash adjustment box". (See page 6-7). Switch setting: 1) FOCUS (Menu setting) ....................... Multi AF Adjusting method: Order Page Address 1 Data Procedure Perfom "Data setting during camera sysem adjustment". (Refer to page 6-13) 60 60 6F 01 02 10 EF [Write] (Note 4) Check the data changes to "01". Check the data is "00"

2 3 4

[Read] [Read]

Note 4: The adjustment data will be automatically input to page: 6F, adress: 10 to 17. Processing after Completing Adjustments: Order Page Address 1 2 60 01 Data 00 [Write] Release "Data settig during camera system adjustment" (Refer to page 6-13) Procedure

6-26

DSC-P8

COVER
1-5. LCD SYSTEM ADJUSTMENTS
1. LCD Initial Data Input Mode Signal Adjustment Page Note 1: Taken an extreme care not to destroy the liquid crystal display module by static electricity when replacing it. Note 2: Set the LCD BRIGHTENSS (SET UP setting) to the NORMAL. Adjustment Address PLAY Arbitrary 4F 80 to 8A, 8D, 92, 93, A3, A4 Before perform the camera system adjustments, check that the specified values of "VIDEO SYSTEM ADJUSTMENTS" are satisfied.

Note: "Memory Stick" must be insertde. Input method: 1) Select page: 00, address: 01, and set data: 01. 2) Select page: 4F, and write the data given in the following table. Address 80 81 82 83 84 85 86 87 88 89 8A 8D 92 93 A3 A4 Data 4E FF 90 9A 91 AF 2D 41 8C 6C 42 BE 2D 0E 24 1C Fixed value Fixed value VCO adjustment (NTSC mode) VCO adjustment (PAL mode) V-COM adjustment Bright adjustment Black Limit adjustment Fixed value White Blance adjustment Contrast adjustment Remark

Processing after Completing Input: 1) Select page: 00, address: 01, and set data: 00.

6-27

DSC-P8

2. VCO Adjustment (SW-386 Board) Set the VCO free-run frequency. If deviated, the LCD screen will be blurred. Mode Signal Measurement Point Adjustment Page Adjustment Address Specified value PLAY Arbitrary Data of page: 40, address: 4F 4F 82 (NTSC mode) 83 (PAL mode) 00

3. Bright Adjustment (SW-386 Board) Set the amplitude of the RGB decoder for driving the LCD to the specified value. If deviated, the LCD screen image will be blackish or saturated (whitish). Mode Signal Measurement Point Adjustment Page Adjustment Address Specified value PLAY Arbitrary Data of page: 40, address: 4F 4F 85 00

Menu setting: 1) VIDEO OUT of SET UP menu ................................. NTSC (NTSC mode) (This adjustment must be performed in NTSC mode, so don't set the menu setting to "PAL") Adjusting method: Order Page Address 1 2 3 4 5 6 7 8 9 10 11 00 4F 4F 40 40 40 4F 40 40 40 40 01 02 99 4F 4E 4F 99 1D 4F 4E 4F Data 01 [Set] 02 [Set] 1C [Set] 01 [Set] 01 [Set] Check that the data satisfied the specified value. Procedure

Adjusting method: Order Page Address 1 2 3 4 5 6 00 4F 4F 40 40 40 01 02 8F 4F 4E 4F Data 01 [Set] 02 [Set] AF [Set] 02 [Set] 01 [Set] Check that the data satisfied the specified value. Procedure

[Read]

Processing after Completing Adjustments: Order Page Address 1 2 4F 00 02 01 Data Procedure

[Read]
1D [Set] 82 [Set] 01 [Set] 01 [Set]

[Read] 00 [Set]

[Read]

Check that the data satisfied the specified value.

Processing after Completing Adjustments: Order Page Address 1 2 3 40 4F 00 1D 02 01 Data 80 [Set] Procedure

[Read] 00 [Set]

6-28

DSC-P8

4. Contrast Adjustment (SW-386 Board) Set the level of the VIDEO signal for driving the LCD to the specified value. If deviated, the LCD screen image will be blackish or saturated (whitish). Mode Signal Measurement Point Adjustment Page Adjustment Address Specified value PLAY Arbitrary Data of page: 40, address: 4F 4F 8A 00

5. Black Limit Adjustment (SW-386 Board) Set the maximum amplitude of the RGB decoder for driving the LCD to the specified value. If deviated, the LCD screen image will be blackish or saturated (whitish). Mode Signal Measurement Point Adjustment Page Adjustment Address Specified value PLAY Arbitrary Data of page: 40, address: 4F 4F 86 00

Note: Perform "Bright Adjustment" before this adjustment. Adjusting method: Order Page Address 1 2 3 4 5 6 00 4F 4F 40 40 40 01 02 91 4F 4E 4F Data 01 [Set] 02 [Set] 40 [Set] 03 [Set] 01 [Set] Check that the data satisfied the specified value. Procedure

Note: Perform "Bright Adjustment" before this adjustment. Adjusting method: Order Page Address 1 2 3 4 5 6 00 4F 4F 40 40 40 01 02 9F 4F 4E 4F Data 01 [Set] 02 [Set] B5 [Set] 04 [Set] 01 [Set] Check that the data satisfied the specified value. Procedure

[Read]

[Read]

Processing after Completing Adjustments: Order Page Address 1 2 4F 00 02 01 Data Procedure

Processing after Completing Adjustments Order Page Address 1 2 4F 00 02 01 Data Procedure

[Read]
00 [Set]

[Read]
00 [Set]

6-29

DSC-P8

6. V-COM Adjustment (SW-386 Board) Set the DC bias of the common electrode drive signal of LCD to the specified value. If deviated, the LCD display will be move, producing flicker and conspicuous vertical lines. Mode Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value 4F 84 The brightness difference between the section-A and section-B is minimum PLAY Arbitrary Check on the LCD screen

7. White Balance Adjustment (SW-386 Board) Correct the white balance. If deviated, the LCD screen color cannot be reproduced. Mode Signal Measurement Point Measuring Instrument Adjustment Page Adjustment Address Specified value 4F 88,89 LCD screen must not be colored PLAY Arbitrary Check on the LCD screen

Note 1: Check the white balance only when replacing the following parts. If necessary, adjust them. 1. LCD901 PANEL UNIT 2. IC101 Adjusting method:

Adjusting method: Order Page Address 1 2 3 4 5 00 4F 40 4F 4F 01 02 F1 84 84 Data 01 [Set] 03 [Set] 82 [Set] Change the data so that brightness of the section A and section B is equal. Procedure

Order Page Address 1 2 3 4 5 00 4F 40 4F 4F 01 02 F1 88 89

Data 01 [Set] 03 [Set] 03 [Set] 8C [Set] 6C [Set]

Procedure

Set the data. (Initial value) Set the data. (Initial value) Check that the LCD screen is not colored. If not colored, proceed to "Processing after Completing Adjustments".

[Write]

Subtract 6 from the data, and write this data.

Processing after Completing Adjustments: Order Page Address 1 2 3 40 4F 00 F1 02 01 Data 00 [Set] Procedure

6

[Read]
00 [Set] 7 4F 88 89

[Write]

Change the data so that the LCD screen is not colored, and write this data.

Processing after Completing Adjustments:
B A

Order Page Address 1 40 4F 00 F1 02 01 2 3

Data 00 [Set]

Procedure

A

B

[Read]
00 [Set]

B

A

A

B

Fig. 6-1-15

6-30

DSC-P8

COVER
6-2. SERVICE MODE
2-1. APPLICATION FOR ADJUSTMENT (SEUS)
2. Operation · Page change To change the page, click [Page] on the SEUS screen and enter the page to be changed. The page is displayed in hexadecimal notation. · Address change To change the address, click [Address] on the SEUS screen and enter the address to be changed. The address is displayed in hexadecimal notation. · Data change To change the data, click [Set] on the SEUS screen and enter the data. The data is displayed in hexadecimal notation. This operation does not write the data to the nonvolatile memory. · Data writing To write the data to the nonvolatile memory, click [Write] on the SEUS screen and enter the data to be written. · Data reading The data displayed on the SEUS screen are the data values at the time when the pages and addresses were set, and they are not updated automatically. To check the data change, click [Read] on the SEUS screen and update the displayed data. 2-1-2. Precaution on Use of SEUS Wrong SEUS operation could clear correct adjustment data. To prevent the data clear by mistake, it is recommended to save all adjustment data by clicking [Page Edit] on the SEUS screen before starting the adjustment.

The application for adjustment (SEUS) is used to change the coefficient for calculating the signal processing or EVR data. The SEUS performs two-way communication between PC and set through the USB terminal. The two-way communication result data can be written to the nonvolatile memory. 2-1-1. Using Method of SEUS 1. Connection 1) Connect the HASP key to the USB terminal of the PC. 2) Connect the PC and set with the USB cable. 3) Confirm that the set starts in the USB mode. 4) Start the SEUS on the PC. 5) Click [Connect] on the SEUS screen. If the connection is normal, the SEUS screen will be as shown in Fig. 6-2-1, indicating the "connected" state. Note: The SEUS will go in "disconnect" state, if the set is turned off (for instance, by resetting the set). In such a case, click [Connect] on the SEUS screen to restore the "connected" state.

Fig. 6-2-1

6-31

DSC-P8

COVER
2-2. DATA PROCESS 2-3.
1.

SERVICE MODE

In some adjustment items, the calculation of SEUS displayed data (hexadecimal) is needed to check the specified data or to acquire the adjustment data. In such a case, prepare a computer capable of calculating hexadecimal numbers. Also, the data at two addresses are read, which are treated as 2 bytes of upper 1 byte and lower 1 byte (4-digit hex. number), to check the specified data.

Setting the Test Mode Address 21 Function Normal Forced MOVIE mode Forced SCN mode Forced CAMERA PROGRAM mode Forced CAMERA mode Forced PLAY mode Forced SET UP mode

Page 2F Data 00 01 02 03 04 08 09

XX XX
Displayed data at lower 1 byte address Displayed data at upper 1 byte address

· Before setting the data, select page: 00, address: 01, and set data: 01. · In the case of page 2F, writing the data by clicking [Write] on the SEUS screen causes the data to be written to the nonvolatile memory. In this case, the Test mode is not released even if the set is turned off, thus requiring extreme care. · After the adjustment/repair finished, be sure to return the data to "00" to restore the Normal mode. Also, select page: 00, address: 01, and set data: 00.

6-32

DSC-P8

2. Bit Value Discrimination In the following items, the bit values must be discriminated from the data displayed on the SEUS. Whether bit values are "1" or "0" can be discriminated from the table shown below. Data displayed on SEUS

3.

Mode Dial Check Address 23 Data 01 SCN CAMERA PROGRAM CAMERA PLAY MOVIE SET UP 02 03 07 Function

Page 20

00
bit 3 to bit 0 discriminated bit 7 to bit 4 discriminated Bit values Display on the SEUS 0 1 2 3 4 5 6 7 A 8 9 A B C D B E F bit3 or bit7 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 bit2 or bit6 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 bit1 or bit5 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 bit0 or bit4 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 4 3 0 1 2 Bit

00 08

Using method: 1) Select page: 20, address: 23. 2) By discriminating the value of dispalyed data, the state of the mode dial can be discriminated.

4.

Switch Check (1) Address 80 Function POWER SW (CONTROL SWITCH BLOCK) When bit value=1 When bit value=0 OFF ON

Page 20

Shutter button (XSHTR ON) (CONTROL SWITCH BLOCK) Shutter button (XAE LOCK ON) (CONTROL SWITCH BLOCK) MEMORY STICK IN SW (MS-130 Board (MS Socket))

OFF

ON

OFF

ON

Example: If the displayed data is "8E", bit 7 - bit 4 values can be discriminated from block (A), and also bit 3 - bit 0 values from block (B).

5

IN

OUT

Using method: 1) Select page: 20, address: 80. 2) By discriminating the bit value of dispaly data, the state of the switches can be discriminated.

6-33

DSC-P8

5. Switch Check (2) Page 20 Addresses 91, 92, 94

Using method: 1) Select page: 20, addresses: 91, 92 and 94. 2) By discriminating the dispaly data, the pressed key can be discriminated. Address 91 (KEY AD0) (IC402 tg) 92 (KEY AD1) (IC402 th) 94 (KEY AD3) (IC402 tk) Data 00 to 0C 0D to 27 28 to 48 49 to 73 74 to A5 A6 to DC DD to FF No key input CONTROL DOWN CONTROL UP IMAGE SIZE/ MENU (SELFTIMER) (STROBO) DELETE (SW-386 board) (SW-386 board) (SW-386 board) (SW-386 board) (S003) (S008) (S004) (S010) CONTROL RIGHT CONTROL LEFT DISPLAY/LCD CONTROL SET (MACRO) (REVIEW) ON/OFF (SW-386 board) (SW-386 board) (SW-386 board) (SW-386 board) (S006) (S007) (S005) (S009) ZOOM (W) ZOOM (T) (SW-386 board) (SW-386 board) (S001) (S002)

No key input

No key input

6. LED Check Page 20 Address 04 Data 02

Using method: 1) Select page: 20, address: 04, set data: 02. 2) Check that all LED (STROB/CHG, POWER, SELF TIMER/ REC, AF ILLUMINATOR, AE/AF LOCK, MS ACCESS) are lit. 3) Select page: 20, address: 04, set data: 00.

7. LCD & Back Light Bright Check Page 40 Address DB Data 02 12 22 DC 00 08 Addresses DB and DC Function Check that LCD brightness is "Dark". Check that LCD brightness is "Normal". Check that LCD brightness is "Bright". Check that Back Light brightness is "Normal". Check that Back Light brightness is "Bright".

8. Self Diagnosis Code Display Code C:32:ss C:13:ss E:61:ss E:91:ss Countermeasure Turn the power off and on again. Format the "Memory stick". Insert a new "Memory Stick". Checking of lens drive circuit. Checking of flash unit or replacement of flash unit. Cause Trouble with hardware. Unformatted memory stick is inserted. Memory stick is broken. When failed in the focus and zoom initialization. Abnormality when flash is being charged. Caution Display During Error SYSTEM ERROR FORMAT ERROR MEMORY STICK ERROR

--

6-34

DSC-P8
FOR CAMERA COLOR REPRODUCTION ADJUSTMENT
Take a copy of CAMERA COLOR REPRODUCTION FRAME with a clear sheet for use.

For NTSC mode

R-Y

R

MG

YE

W B-Y B

G

CY

DSC-P8




6-35E 6-35

Reverse

987622651.pdf

Revision History